| Payment Terms | T/T, L/C, Payment Term Is Negotiable |
| Supply Ability | 500 Sets Per Month |
| Delivery Time | 15-35 Days |
| Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
| Application | Industrial Ventilation |
| Drivetrain | Direct/Coupling Driven/V-belt Driven |
| Impeller | Dynamic Balanced |
| Motor type | Three Phase AC Motor |
| Bearing Type | Rolling bearing |
| Type | Centrifugal Fan |
| Brand Name | SIMO |
| Model Number | SIMO Blower 6-06 |
| Certification | CE, ISO9001:2008,TUV |
| Place of Origin | Henan China |
View Detail Information
Explore similar products
Cement Plant Raw Material Wear Resistant Circulation Fan
Corrosion Resistant Centrifugal Fans Transporting Toxic Gases
Air Blower For Road Street Sweeper Fans System
Good Sealing Preservative Zero Leakage Centrifugal Fans
Product Specification
| Payment Terms | T/T, L/C, Payment Term Is Negotiable | Supply Ability | 500 Sets Per Month |
| Delivery Time | 15-35 Days | Packaging Details | Export Wooden Case Packing, Steel pallet Packing |
| Application | Industrial Ventilation | Drivetrain | Direct/Coupling Driven/V-belt Driven |
| Impeller | Dynamic Balanced | Motor type | Three Phase AC Motor |
| Bearing Type | Rolling bearing | Type | Centrifugal Fan |
| Brand Name | SIMO | Model Number | SIMO Blower 6-06 |
| Certification | CE, ISO9001:2008,TUV | Place of Origin | Henan China |
| High Light | TUV Backward Explosion Proof Blower ,3Phase AC Motor Explosion Proof Blower ,Wear Resistant Backward Centrifugal Fan | ||
AC Motor Backward Explosion Proof Blower High Wear Resistance
Introduction
The 6-06.51 series boiler fan is mainly used for the fan system of the 2t/h~670t/h steam boiler of the thermal power plant, and also meets the requirements of the performance parameters of the high pressure head of the fluidized bed furnace.
This series of fan design is based on aerodynamic sketches determined by more than one year of model test and adopts advanced proprietary technology, such as high-strength wear-resistant impeller and anti-leakage bearing housing.
Detail introduction
1. The parts are tightly matched and the sealing performance is good, ensuring that the output pressure will not decrease.
2. After the completion of production, after running test and vibration value detection, reliable operation.
3. In order to overcome the insufficient pumping force due to the above reasons, the furnace has a positive pressure, which affects the combustion and normal operation of the boiler.
Technical data
| series | model | Rotation Speed (r/min) |
Total Pressure (Pa) |
Air Capacity (m³/h) |
Power (kW) |
|---|---|---|---|---|---|
| 6-06 | 8D | 1450 | 1859~2745 | 11000~26400 | 15 ~ 22 |
| 9D | 1450 | 2353~3474 | 15700~37500 | 30 ~ 45 | |
| 10D | 1450 | 2905~4289 | 21500~51500 | 45 ~ 75 | |
| 11D | 960 ~ 1450 | 1541~5190 | 22700~68500 | 22 ~ 110 | |
| 12D | 960 ~ 1450 | 1834~6176 | 24600~89000 | 37 ~ 160 | |
| 13D | 960 ~ 1450 | 2152~7248 | 31200~113000 | 55 ~ 250 | |
| 14D | 960 ~ 1450 | 2496~8406 | 39000~141000 | 75 ~ 400 | |
| 15D | 730 ~ 1450 | 1657~9650 | 36600~172000 | 45 ~ 500 | |
| 16D | 730 ~ 1450 | 1885~10980 | 44300~211000 | 75 ~ 710 | |
| 17D | 730 ~ 960 | 2128~5433 | 53200~168000 | 90 ~ 280 | |
| 18D | 730 ~ 960 | 2386~6091 | 63100~199000 | 110 ~ 355 | |
| 19D | 730 ~ 960 | 2658~6787 | 74200~234000 | 160 ~ 500 | |
| 20D | 730 ~ 960 | 2946~7520 | 86700~273000 | 200 ~ 630 | |
| 21D | 580 ~ 960 | 2050~8290 | 79500~316000 | 200 ~ 800 | |
| 22D | 580 ~ 960 | 2250~9099 | 92200~363000 | 220 ~ 1000 | |
| 23.5D | 580 ~ 960 | 2567~10380 | 112000~443000 | 220 ~ 1400 | |
| 25D | 580 ~ 730 | 6794~6464 | 134000~406000 | 355 ~ 800 | |
| 26.5D | 480 ~ 730 | 2236~7633 | 132000~483000 | 220 ~ 1120 | |
| 28D | 480 ~ 730 | 2496~8522 | 156000~569000 | 315 ~ 1400 | |
| 29.5D | 480 ~ 730 | 2771 ~ 9460 | 183000~667000 | 400 ~ 2000 |
Product Features
1. In the use of common base, the installation is very simple and requires little support from a professional technician.
2. The range of high-efficiency working conditions is wide, the machine numbers are arranged intensively, and it is easy to select high-efficiency working conditions.
FAQ
1, What parameters need to be provided when you design the industrial centrifugal fans?
A: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2, How about your company’s pre-sales service and after-sales service?
A: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3, Does your company have qualifications?
A: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.
![]()
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
1955
Total Annual:
3500000-25000000$
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Xinxiang SIMO Blower Co., Ltd which was founded in 1955,with a registered capital of RMB50,000,000. mainly designs and manufactures Centrifugal fans and Axial flow fans which are applied to industrial systems, which is the senior member of China General Machinery Industry Association ... Xinxiang SIMO Blower Co., Ltd which was founded in 1955,with a registered capital of RMB50,000,000. mainly designs and manufactures Centrifugal fans and Axial flow fans which are applied to industrial systems, which is the senior member of China General Machinery Industry Association ...
Get in touch with us
Leave a Message, we will call you back quickly!