| Breaking capacity | 6KA |
| Warranty | 2 Years |
| Product name | Residual Current Operated RCBO |
| Protection | Other |
| Standard | IEC61009-1 |
| Type | RCBO, Residual Current |
| Mounting Type | Rail Mounting |
| Rated residual operating current (mA) | 10mA 30mA 100mA 300mA |
| Mechanical Life | 10000 Times |
| Material | Copper |
| Rated Frequency (Hz) | 50 Hz |
| Rated current | 10A/16A/20A/25A/32A/40A/63A |
| Poles Number | 2 |
| Rated Voltage | 230 V |
| Application | Circuit-Breaking, Households |
| Breaking Capacity | 6 kA |
| BCD Curve | Type A, Type AC |
| Model Number | MWB8L-40 |
| Place of Origin | Zhejiang, China |
| Brand Name | OEM |
| Certification | CE,TUV |
View Detail Information
Explore similar products
4-Pole 63A Residual Current Circuit Breaker Type B RCCB with 63 Amp Capacity
4 Pole Electromagnetic Type RCCB Residual Current Circuit Breaker AC 25a 40a 63a
2 Pole Type B RCCB MCB Circuit Breaker Without Overcurrent protection 25A 40A
Circuit Breaker with Overcurrent protection Type AC with 6A 10A 16A 20A 25A 32A
Product Specification
| Breaking capacity | 6KA | Warranty | 2 Years |
| Product name | Residual Current Operated RCBO | Protection | Other |
| Standard | IEC61009-1 | Type | RCBO, Residual Current |
| Mounting Type | Rail Mounting | Rated residual operating current (mA) | 10mA 30mA 100mA 300mA |
| Mechanical Life | 10000 Times | Material | Copper |
| Rated Frequency (Hz) | 50 Hz | Rated current | 10A/16A/20A/25A/32A/40A/63A |
| Poles Number | 2 | Rated Voltage | 230 V |
| Application | Circuit-Breaking, Households | Breaking Capacity | 6 kA |
| BCD Curve | Type A, Type AC | Model Number | MWB8L-40 |
| Place of Origin | Zhejiang, China | Brand Name | OEM |
| Certification | CE,TUV |
![]()
![]()
Residual Current Operated Circuit Break with overcurrent protection 6a 10a 16a 20a 25a 32a 40a RCBO circuit breaker
YMWB8L-40 Residual Current Operated
Circuit Breaker with overcurrent protection(Electro magnetic)
Application:
The Product serves in the line of AC 50Hz,rated voltage 230V and rated current up to 40A to automatically and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value.It can effectively protect personal security and avoid the damage to equipments.
The circuit-breaker can also function as overload and short-circuit protection and unfrequent changeover of line under normal condition.
The product is conformity with GB16917.1,IEC61009-1 Standards.
Feature:
1. Without auxiliary power supply,the product is designed with strong immunity and extending protection range against residual current.
2. With higher rated ultimate short circuit,up to 6KA.
3. Reliable,accurate and convenient adjustment of product instantaneous action is ensured.
4. Service life of product has been greatly enhanced through specially designed tripping mechanism.
Technical parameters:
1. Rated Current: 6A,10A,16A,20A,25A,32A,40A.
2. Rated residual operating current:0.01A,0.03A,0.1A,0.3A.
3. Tripping Characteristics: B(3ln~5ln),C(5ln~10ln)
4. According to behaviour in presence of d.c Components:Type A,Type AC.
5. Icn:6000A
6. Rated residual current operated making and breaking capacity IΔm: 500A
7. Rated residual non-operated current IΔno: 0.5IΔn.
-----------------------------------------------------------------------------------------------------------------------------------------
Main Technical Parameter:
| Rated Current | 6A,10A,16A,20A,25A,32A,40A |
| Rated residual operating current | 0.01A,0.03A,0.1A,0.3A |
| Tripping Characteristics | B(3ln~5ln),C(5ln~10ln) |
| According to behaviour in presence of d.c Components | Type A,Type AC |
| Icn | 6000A |
| Rated residual current operated making and breaking capacity IΔm | 500A |
| Rated residual non-operated current IΔno | 0.5IΔn |
YMWB8LE-40 Residual Current Operated
Circuit Breaker with overcurrent protection(Electronic)
Application:
The Product serves in the line of AC 50Hz,rated voltage 230V and rated current up to 40A to automatically and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value.It can effectively protect personal security and avoid the damage to equipments.
The circuit-breaker can also function as overload and short-circuit protection and unfrequent changeover of line under normal condition.
The product is conformity with GB16917.1,IEC61009-1 Standards.
Feature:
1. With higher rated ultimate short circuit,up to 6kA.
2. Reliable,accurate and convenient adjustment of product instantaneous action is ensured.
3. Service life of product has been greatly enhanced through specially designed tripping mechanism.
Main Technical Data:
1. Rated Current: 6A,10A,16A,20A,25A,32A,40A.
2. Rated residual operating current: 0.03A,0.1A.
3. Tripping Characteristics: B,C
4. Icn:6000A
5. Rated residual current operated making and breaking capacity IΔm: 500A
6. Rated residual non-operated current: IΔno: 0.5IΔn.
2P and 4P RCBO Related Products shown:
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
![]()
Company Details
Business Type:
Trading Company,Manufacturer
Year Established:
2018
Total Annual:
2500000-5000000
Employee Number:
101~200
Ecer Certification:
Verified Supplier
WENZHOU MEIHENG ELECTRIC CO.,LTD is located in Xiangyang Industrial Zone,Liushi Town,Yueqing City,Zhejiang Province,China.Our company was founded in 2000 year,and our company with an area of 3,000 square meters.Our company's products line mainly include computerized Cam Switch,Changeover Switch,Rota... WENZHOU MEIHENG ELECTRIC CO.,LTD is located in Xiangyang Industrial Zone,Liushi Town,Yueqing City,Zhejiang Province,China.Our company was founded in 2000 year,and our company with an area of 3,000 square meters.Our company's products line mainly include computerized Cam Switch,Changeover Switch,Rota...
Get in touch with us
Leave a Message, we will call you back quickly!