| Input voltage | 85V - 265V AC |
| Frequency range | 20kHz - 500kHz |
| Delivery Time | 7-14 work days (Negotiable) |
| Core material | Ferrite |
| Payment Terms | T/T |
| Operating temperature | -40°C to +125°C |
| Supply Ability | 10000pcs |
| Isolation voltage | 3000V AC |
| Power rating | 5W - 500W |
| Certification | UL/cUL Class B/F/H, VDE, CQC |
| Model Number | EC39 |
| Brand Name | CHIPSEN |
| Place of Origin | China |
View Detail Information
Explore similar products
Custom EE25 Ferrite Core Transformer For Industrial LED Driver Power
EP7 Mini SMPS Pulse Transformer Excellent EMI Shielding Custom SMD PCB Mount
EP13 12V 24V High Frequency SMPS Transformer For Power Supply Telecom And
Custom EE19 Ferrite Core High Frequency SMPS Transformer For Industrial Power
Product Specification
| Input voltage | 85V - 265V AC | Frequency range | 20kHz - 500kHz |
| Delivery Time | 7-14 work days (Negotiable) | Core material | Ferrite |
| Payment Terms | T/T | Operating temperature | -40°C to +125°C |
| Supply Ability | 10000pcs | Isolation voltage | 3000V AC |
| Power rating | 5W - 500W | Certification | UL/cUL Class B/F/H, VDE, CQC |
| Model Number | EC39 | Brand Name | CHIPSEN |
| Place of Origin | China | ||
| High Light | EC39 hf power transformer ,Low DCR hf power transformer ,500W high frequency transformer | ||
| Industry | Typical Application | Typical Input Requirement | Typical Output Requirement | Typical Power Inquiry | Frequency | Key Parameters Evaluated | Safety and Environmental Focus | Available Customization |
|---|---|---|---|---|---|---|---|---|
| Industrial automation | Isolated SMPS power for PLC controllers drives and control boards | Switched excitation derived from 12 V 24 V or 48 V DC or a rectified AC bus | 5 V 12 V 15 V 24 V 36 V 48 V or multiple outputs | Approximately 15 W to 120 W | Commonly 30 kHz to 300 kHz | Inductance turns ratio leakage DCR peak current regulation EMI and temperature rise | Industrial insulation creepage clearance vibration and cabinet temperature | Gap winding sequence conductor shield pinout leads insulation and test limits |
| Emergency power and UPS | Battery converter auxiliary supply gate drive and charger control | Battery or high-voltage DC bus with customer-defined waveform | 12 V 15 V 24 V 48 V or multiple isolated rails | Approximately 30 W to 200 W | Commonly 30 kHz to 250 kHz | Peak current flux margin leakage DCR efficiency isolation and temperature rise | Continuous standby surge environment and thermal endurance | Low-loss material precision gap low-DCR winding multiple outputs and reinforced insulation |
| Energy storage systems | PCS auxiliary power BMS supply gate drive and controls | Battery or rectified high-voltage bus through the specified topology | Isolated control rails or application-specific power outputs | Approximately 30 W to 250 W | Commonly 40 kHz to 300 kHz | Capacitance isolation leakage DCR saturation margin EMI and thermal stability | High-voltage separation surge cabinet environment and traceability | Low-capacitance winding shield reinforced insulation foil leads and potting |
| Battery chargers | Main or auxiliary transformer for industrial chargers | 12 V to 72 V DC or rectified 85 V to 265 V AC depending on architecture | Customer-specified charging or auxiliary output | Approximately 30 W to 250 W | Commonly 40 kHz to 250 kHz | Inductance peak current leakage DCR regulation insulation and losses | Creepage clearance dielectric strength surge and thermal margin | Topology-specific gap turns ratio litz wire foil shield insulation and pin layout |
| Telecom and networking | Converter transformer for communication equipment | Common 24 V or 48 V DC bus or rectified-input converter | 5 V 12 V 24 V 48 V or multiple regulated rails | Approximately 20 W to 150 W | Commonly 50 kHz to 300 kHz | DCR leakage capacitance EMI regulation and footprint | Isolation EMC support cabinet temperature and reliability | Low-capacitance winding shield interleaving custom ratio pinout and leads |
| Data center power electronics | Server auxiliary converters and gate-drive circuits | PFC DC bus battery bus or auxiliary converter stage | Isolated housekeeping control or gate-drive rails | Approximately 20 W to 200 W | Commonly 50 kHz to 300 kHz | Leakage AC and DC resistance capacitance core loss and thermal path | Insulation coordination traceability and temperature cycling | Controlled leakage foil winding shield custom pins leads and test tolerances |
| EV charging equipment | Auxiliary SMPS control power and gate-drive power | Rectified mains DC link or low-voltage auxiliary bus | 12 V 15 V 24 V or multiple isolated outputs | Approximately 20 W to 200 W | Commonly 40 kHz to 250 kHz | Isolation leakage capacitance DCR peak current EMI and temperature rise | Charger insulation surge humidity vibration and traceability | Reinforced insulation shield low-capacitance winding custom leads and potting |
| Medical equipment | Power for diagnostic monitoring and laboratory subsystems | Customer-defined converter bus and switching waveform | Application-specific isolated outputs | Approximately 20 W to 150 W | Commonly 40 kHz to 250 kHz | Creepage clearance dielectric strength capacitance and temperature rise | Coordination with applicable medical end-equipment requirements | Reinforced insulation triple-insulated wire shield custom spacing and documented tests |
| HVAC and industrial controls | Drive auxiliary supply and motor-control electronics | Rectified mains DC link or 24 V to 48 V DC auxiliary bus | Control fan relay sensor or gate-drive outputs | Approximately 20 W to 150 W | Commonly 30 kHz to 250 kHz | Saturation margin DCR leakage regulation EMI and vibration resistance | Industrial temperature humidity surge and pollution degree | Multi-output design shield gap leads potting and mechanical reinforcement |
| Construction Item | EC39 Customization Reference |
|---|---|
| Magnetic platform | EC39 ferrite-core platform or approved equivalent selected according to frequency flux density losses and thermal requirements |
| Core material | High-frequency ferrite grade selected according to waveform frequency temperature and loss target |
| Bobbin | Multi-pin through-hole bobbin selected for winding space pin layout creepage clearance and PCB mounting |
| Pin configuration | Multiple PCB pins are visible but exact count pitch and assignment require drawing confirmation |
| Flying leads | Insulated flying leads with customizable gauge rating length color stripping connectors and electrical functions |
| Winding conductor | Enameled wire parallel conductors litz wire copper foil or triple-insulated wire |
| Winding arrangement | Layered interleaved sectional bifilar or separated structure |
| Insulation system | Bobbin tape margin barriers sleeving triple-insulated wire and lead insulation |
| Shielding | Optional electrostatic shield flux band or shield winding |
| Air gap | Ungapped distributed-gap or precision center-gap construction |
| Core fixing | Tape adhesive clamp or approved bonding process |
| Impregnation and potting | Varnish partial potting or encapsulation according to thermal and environmental requirements |
| Traceability | Custom model winding identification date code lot code and customer label |
Company Details
Business Type:
Manufacturer
Year Established:
2007
Total Annual:
28820000-29820000
Employee Number:
400~450
Ecer Certification:
Verified Supplier
Chipsen Electronics - Supplier to Fortune Global 500 Companies Magnetic Components Engineered for Performance & Reliability Founded in 2007, Dongguan Chipsen Electronics Technology Co., Ltd. is a professional manufacturer specializing in magnetic components and micro switches. ... Chipsen Electronics - Supplier to Fortune Global 500 Companies Magnetic Components Engineered for Performance & Reliability Founded in 2007, Dongguan Chipsen Electronics Technology Co., Ltd. is a professional manufacturer specializing in magnetic components and micro switches. ...
Get in touch with us