| Cooling Method | Natural Air Cooling |
| Delivery Time | 15-30 working days |
| Input Voltage | 100V - 480V AC Customizable |
| Packaging Details | Carton |
| Payment Terms | T/T |
| Power rating | 40VA/Custom |
| Operating Frequency | 50Hz / 60Hz |
| Output Voltage | 6V - 240V AC Customizable |
| Supply Ability | 1K-3K PCS/Month |
| Winding Material | 100% Copper Wire |
| Model Number | EI76 |
| Brand Name | Chipsen |
| Place of Origin | China |
| Certification | UL/ISO9001/ISO14001/RoHS/Reach |
View Detail Information
Explore similar products
Durable Vacuum Potted EI57 Power Transformer for Reliable Control System Unit
EI76 EI96 Industrial Control Transformer 50/60Hz AC Step Down Control Power
Reliable EI48 Encapsulated Transformer for Industrial Control Power Modules
Stable Silicon Steel EI96 Low Frequency Transformer for Power Supply System
Product Specification
| Cooling Method | Natural Air Cooling | Delivery Time | 15-30 working days |
| Input Voltage | 100V - 480V AC Customizable | Packaging Details | Carton |
| Payment Terms | T/T | Power rating | 40VA/Custom |
| Operating Frequency | 50Hz / 60Hz | Output Voltage | 6V - 240V AC Customizable |
| Supply Ability | 1K-3K PCS/Month | Winding Material | 100% Copper Wire |
| Model Number | EI76 | Brand Name | Chipsen |
| Place of Origin | China | Certification | UL/ISO9001/ISO14001/RoHS/Reach |
| High Light | EI76 control transformer for HVAC ,industrial control panel transformer ,EI76 transformer with warranty | ||
The EI76 Low Frequency Transformer is designed for stable voltage conversion, electrical isolation, and auxiliary power supply applications in industrial and commercial equipment. Built with high-quality silicon steel laminations and pure copper windings, it delivers reliable performance, low temperature rise, and long service life under continuous operation.
This transformer can be customized for step-down, step-up, isolation, and control circuit applications. Input voltage, output voltage, VA rating, lead wires, terminals, mounting structure, insulation class, and thermal protection can all be tailored according to customer requirements. It is widely used in control panels, HVAC equipment, industrial automation, machine tools, energy systems, and commercial appliances.
| Parameter | Specification |
|---|---|
| Core Type | EI76 Laminated Silicon Steel Core |
| Operating Frequency | 50Hz / 60Hz |
| Input Voltage | 100V - 480V AC Customizable |
| Output Voltage | 6V - 240V AC Customizable |
| Rated Power | 20VA - 300VA Customizable |
| Winding Material | 100% Copper Wire |
| Insulation Class | Class B / F / H Optional |
| Dielectric Strength | Up to 3000VAC / 1 Minute |
| Temperature Rise | ≤80℃ |
| Mounting Type | Bracket Mount / Chassis Mount |
| Cooling Method | Natural Air Cooling |
| Noise Level | Low Audible Noise Design |
| Protection Options | Thermal Fuse / Thermal Protector Optional |
| Operating Temperature | -20℃ to +105℃ |
| Customization | Voltage, Current, VA, Leads, Terminals, Shielding |
Yes. We can customize primary voltage, secondary voltage, VA rating, winding configuration, insulation class, lead wires, terminals, and mounting structure according to your specifications and drawings.
Please provide input voltage, output voltage, output current or VA rating, operating frequency, mounting method, lead type, insulation requirements, and estimated annual quantity.
Yes. The transformer can be designed for continuous-duty operation with appropriate temperature rise limits, insulation systems, and thermal protection based on your application requirements.
An isolation transformer primarily provides electrical isolation between circuits, while a control transformer is optimized to deliver stable voltage for relays, contactors, PLCs, and control systems.
Yes. Thermal fuses, thermal protectors, and other protection devices can be integrated to improve safety and protect equipment from overheating conditions.
Each transformer undergoes comprehensive testing including turns ratio, no-load current, load performance, winding resistance, dielectric withstand voltage, insulation resistance, and final visual inspection.
Yes. EI76 transformers are widely used in HVAC controls, PLC panels, machine tools, building automation systems, relays, contactors, and industrial control equipment.
Samples are usually completed within 3–5 working days after specification confirmation. Mass production typically requires 15–30 days depending on design complexity and order quantity.
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2007
Total Annual:
28820000-29820000
Employee Number:
400~450
Ecer Certification:
Verified Supplier
Chipsen Electronics - Supplier to Fortune Global 500 Companies Magnetic Components Engineered for Performance & Reliability Founded in 2007, Dongguan Chipsen Electronics Technology Co., Ltd. is a professional manufacturer specializing in magnetic components and micro switches. ... Chipsen Electronics - Supplier to Fortune Global 500 Companies Magnetic Components Engineered for Performance & Reliability Founded in 2007, Dongguan Chipsen Electronics Technology Co., Ltd. is a professional manufacturer specializing in magnetic components and micro switches. ...