China factories

China factory - CITEST DIAGNOSTICS INC.

CITEST DIAGNOSTICS INC.

  • China,Hangzhou ,Zhejiang
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 300ng/ML 7-ACL Dispoable Drug Abuse Test Kit OEM 7 Aminoclonazepam Drug Test
China 300ng/ML 7-ACL Dispoable Drug Abuse Test Kit OEM 7 Aminoclonazepam Drug Test

  1. China 300ng/ML 7-ACL Dispoable Drug Abuse Test Kit OEM 7 Aminoclonazepam Drug Test
  2. China 300ng/ML 7-ACL Dispoable Drug Abuse Test Kit OEM 7 Aminoclonazepam Drug Test
  3. China 300ng/ML 7-ACL Dispoable Drug Abuse Test Kit OEM 7 Aminoclonazepam Drug Test

300ng/ML 7-ACL Dispoable Drug Abuse Test Kit OEM 7 Aminoclonazepam Drug Test

  1. MOQ: N/A
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 10 M tests/month
Delivery Time 2-4 Weeks
Packaging Details 40T/50T
Product 300ng/mL 7-Aminoclonazepam (7-ACL) Dispoable Rapid Drug Abuse Kits Cassette/Dipstick/Strip Test Kit OEM With CE
Cat. No. DACL-102/111/114
Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup
Specimen Urine, Powder
Certificate CE
Reading Time 5 minutes
Pack 40T/50T
Storage Temperature 2-30°C
Shelf Life 2 Years
Sensitivity 94.7%
Specificity 97.5%
Accuracy 96.2%
Cut-Off 300 ng/mL*
Brand Name Citest
Model Number DACL-102/111/114
Certification CE
Place of Origin -

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 10 M tests/month Delivery Time 2-4 Weeks
Packaging Details 40T/50T Product 300ng/mL 7-Aminoclonazepam (7-ACL) Dispoable Rapid Drug Abuse Kits Cassette/Dipstick/Strip Test Kit OEM With CE
Cat. No. DACL-102/111/114 Principle Chromatographic Immunoassay
Format Dipstick, Cassette, Panel, Cup Specimen Urine, Powder
Certificate CE Reading Time 5 minutes
Pack 40T/50T Storage Temperature 2-30°C
Shelf Life 2 Years Sensitivity 94.7%
Specificity 97.5% Accuracy 96.2%
Cut-Off 300 ng/mL* Brand Name Citest
Model Number DACL-102/111/114 Certification CE
Place of Origin -
High Light 7 ACL Dispoable Drug Abuse Test Kit300ng/ML 7 ACL Drug Abuse Test KitOEM 7 Aminoclonazepam Drug Test

7-Aminoclonaze/pam (7-ACL) Dispoable Rapid ​ Drug Abuse 300ng/mL* Test Kit OEM Diagnosis of CE

 

Applications:

 

The ACL Rapid Test Dipstick (Urine) is a rapid chromatographic immunoassay for the detection of 7-Aminoclonaze/pam (major metabolite) in urine at a cut-off concentration of 100ng/ml. This test will detect other related compounds, please refer to the Analytical Specificity table in this package insert.


This assay provides only a qualitative, preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

 

Description:

 

7-aminoclo/nazepam is the major metabolite of clona/zepam. Clonaz/epam sold under the brandname Klonopin among others, is a medication used to prevent and treat seizures, panic disorder, and for the movement disorder known as akathisia. It is a type of benzodiazepine. As a major metabolite, 7-aminoclonazepam may be used to monitor use of the parent drug, clona/zepam. Clonaz/epam, marketed as Klonopin and Rivotril, is a long-acting benzodiazepine with anxiolytic, anticonvulsant, muscle relaxant, and hypnotic properties.
 

How to use?

 

Allow the test, urine specimen, and/or controls to reach room temperature (15-30°C) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test cassette from the sealed pouch and use it within one hour.
2. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 full drops of urine (approx. 120μL) to the specimen well (S) of the test cassette, and then start the timer. Avoid trapping air bubbles in the specimen well (S). See the illustration below.
3. Wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10minutes.

 

DIRECTIONS FOR PANEL USE


Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test panel from the sealed pouch and use it within one hour.
2. Remove the cap.
3. With the arrow pointing toward the urine specimen, immerse the test panel vertically in the urine specimen for at least 10 to 15 seconds. Immerse the strip to at least the level of the wavy lines, but not above the arrow on the test panel.
4. Replace the cap and place the test panel on a non-absorbent flat surface.
5. Start the timer and wait for the colored line(s) to appear.
6. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.

 

DIRECTIONS FOR DIPSTICK USE


Allow the test, urine specimen, and/or controls to reach room temperature (15-30ºC) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test dipstick from the sealed pouch and use it within one hour.
2. With arrows pointing toward the urine specimen, immerse the test dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the Test Dipstick when immersing the strip. See the illustration below.
3. Place the test dipstick on a non-absorbent flat surface, start the timer and wait for the colored line(s) to appear. Read results at 5 minutes. Do not interpret the result after 10 minutes.

 

 

 

INTERPRETATION OF RESULTS


(Please refer to the illustration above)


NEGATIVE:* Two lines appear. One colored line should be in the control line region (C), and another apparent colored line should be in the test line region (T). This negative result indicates that the 7-Aminoclonazepam (7-ACL) concentration is below the detectable cut-off level.


*NOTE: The shade of color in the test line region (T) may vary, but it should be considered negative whenever there is even a faint colored line.


POSITIVE: One colored line appears in the control line region (C). No line appears in the test line region (T). This positive result indicates that the 7-Aminoclonazepam (7-ACL) concentration exceeds the detectable cut-off level.


INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

 

 

 

Cat. No. Product Description Specimen Format Kit Size Cut-Off Status
DACL-102 7-Aminoclonazepam (7-ACL) Rapid Test Cassette Urine Cassette 40 T 300ng/mL* CE
DACL-114 7-Aminoclonazepam (7-ACL) Rapid Test Panel Urine Panel 40 T CE
DACL-101 7-Aminoclonazepam (7-ACL) Rapid Test Dipstick Urine Dipstick 50 T CE
 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Trading Company

  • Total Annual:

    80000000-100000000

  • Employee Number:

    500~10000

  • Ecer Certification:

    Verified Supplier

CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ... CITEST DIAGNOSTICS INC., an emerging In Vitro Diagnostics company based in Canada, is experiencing growth on a global scale, engaging in multinational operations. CITEST was founded by highly experienced IVD industry professionals with proven track records building and growing successful companies. ...

+ Read More

Get in touch with us

  • Reach Us
  • CITEST DIAGNOSTICS INC.
  • 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA
  • https://www.citesttestkit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement