Payment Terms | L/C, T/T, Western Union |
Delivery Time | 20 days |
Packaging Details | Polywood packing |
clean room class | ISO 5 - 8 |
cooling/heating | auto change (heat option) |
capacity range | 7.5 ton - 30 ton |
scope | struture , HVAC , electricity / monitoring |
period | 1 - 4 months |
service | field installation , commissioning and training,engineer are able to service machinery overseas |
document | verification and certification |
usage | air purification system |
Brand Name | alphaclean |
Model Number | ISO clean room |
Certification | ce |
Place of Origin | china |
View Detail Information
Explore similar products
GMP Sterile Aseptic ISO Laboratory Clean Rooms Physical Chemical
ISO soft color Class 100 Laminar Flow Operating Room For Hospital
Sterile Customized Dimension ISO Clean Rooms For Food Beverage Packaging
ISO 8 Monitoring HVAC GMP Clean Room In Pharmaceutical Industry
Product Specification
Payment Terms | L/C, T/T, Western Union | Delivery Time | 20 days |
Packaging Details | Polywood packing | clean room class | ISO 5 - 8 |
cooling/heating | auto change (heat option) | capacity range | 7.5 ton - 30 ton |
scope | struture , HVAC , electricity / monitoring | period | 1 - 4 months |
service | field installation , commissioning and training,engineer are able to service machinery overseas | document | verification and certification |
usage | air purification system | Brand Name | alphaclean |
Model Number | ISO clean room | Certification | ce |
Place of Origin | china | ||
High Light | Customized Sterile Cleanrooms ,Food Packaging Customized Sterile Cleanrooms ,Beverage Packaging ISO Clean Rooms |
Customized Sterile Cleanrooms For Food And Beverage Packaging
New Air Percentage | |||
Food packaging workshop guidelines:
1. The air supply in the food packaging clean room is sufficient to dilute or eliminate the pollution generated indoors.
2. The air in the clean room flows from the clean area to the low cleanliness area. The flow of contaminated air is minimal, and the air flow direction at the door and in the indoor building is correct.
3. air supply will not significantly increase indoor pollution.
4. indoor air movement state can ensure that there is no high concentration area in the chamber.
Food and pharmaceutical packaging workshop testing standards
1. Air supply volume and exhaust air volume:
If it is a turbulent clean room, measure the air supply volume and exhaust air volume. If it is a one-way flow clean room, measure the air flow speed.
2. Airflow control between each zones:
In order to prove that the direction of airflow movement between the various areas of the purification plant is correct, that is testing the flow from the high clean area to low cleanliness area
1) The pressure difference between each zone is correct
2) The airflow in the opening at the door or at the wall, floor, etc. is in the correct direction, that is, from the clean area to the low cleanliness area.
3. Filter leak detection:
The high-efficiency filter and its frame are inspected to ensure that suspended contaminants do not pass through.
1) Damaged filter
2) The gap between the filter and its outer frame
3) Invaded from other parts of the filter unit.
4. Isolation leak detection:
This test is to prove that suspended pollutants do not penetrate the clean room through building materials.
5. clean room indoor airflow control:
The type of airflow control test depends on the airflow mode - whether it is turbulent or one-way flow. If the clean room airflow is turbulent, it must be verified that there is no insufficient airflow area in the clean room. In the case of a one-way flow clean room, it must be verified that the wind speed and direction of the entire room meet the design requirements.
6. Suspended particle concentration and microbial concentration:
If these above tests meet the requirements, the particle concentration and microbial concentration are finally measured if needed to verify that it meets the technical requirements for clean room design.
Advantage of ISO Clean Room
1. Easy to disassemble and install according to drawings
The construction scheme of modular clean room has many advantages. The accessories of modular system have been verified by a large number of practical use in the experiment of controlling the manufacturing environment. The assembly of clean room with modular system can greatly reduce the design, construction, engineering time and engineering cost of clean room. Modular clean room can usually improve the efficiency by 20 ~ 40% compared with the traditional standardized clean room system. If the clean room needs to be relocated or reconfigured and transformed after completion, the use of modular system is also very conducive to future transformation and clean room migration.
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
200000-400000
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Alpha clean air technology co ltd is a Cleanroom Turnkey Solution provider specializing in design,manufacturing,construction,commissioning and validation services of cleanrooms and associated products. The company is located in the Shenzhen Guangdong Province, The company has established a t... Alpha clean air technology co ltd is a Cleanroom Turnkey Solution provider specializing in design,manufacturing,construction,commissioning and validation services of cleanrooms and associated products. The company is located in the Shenzhen Guangdong Province, The company has established a t...