Payment Terms | T/T, Western Union |
Supply Ability | 30 Sets per Month |
Delivery Time | Within 30 ~ 45 workdays |
Packaging Details | Standard export plywood case |
Interior dimension | 400*350*350 MM |
Exterior dimension | 1400*1800*1400 MM |
Test Volue | 49 Liters |
Temperature range | -40~150 Deg C |
Power | AC380V, 3 Phase |
Brand Name | ASLI |
Model Number | TS-49-A |
Certification | CE,SGS,Calibration Report |
Place of Origin | China,DongGuan |
View Detail Information
Explore similar products
IEC60068-2-78 Laboratory Equipment Thermal Shock Test Chamber Easy to Operate
SUS 304# Temperature Cycling Thermal Shock Chamber -40 To 150 Degree
Touch Screen Climatic Thermal Shock Chamber / Temperature Shock Test Equipment
Three Boxes Environmental Climatic Thermal Test Chamber / Impact Testing Machine
Product Specification
Payment Terms | T/T, Western Union | Supply Ability | 30 Sets per Month |
Delivery Time | Within 30 ~ 45 workdays | Packaging Details | Standard export plywood case |
Interior dimension | 400*350*350 MM | Exterior dimension | 1400*1800*1400 MM |
Test Volue | 49 Liters | Temperature range | -40~150 Deg C |
Power | AC380V, 3 Phase | Brand Name | ASLI |
Model Number | TS-49-A | Certification | CE,SGS,Calibration Report |
Place of Origin | China,DongGuan | ||
High Light | thermal shock testing ,thermal shock test chamber |
49 Liters Touch Screen Cold Thermal Shock Chamber with Stainless Steel Material
Standards comply with:
GB/T 2431.1-2001 Testing A: Low temperature testing method
GB/T 2431.2-2001 Testing B: High temperature testing method
GJB 150.3-1986: High temperature
GJB 150.4-1986: Low temperature
IEC68-2-1 Test A: Cold
IEC68-2-2 Test A: Dry
GB 11158 High and low temperature test term
GB/T 2423.2 << Electrolic products basic environmental test: B: high temperature method>>
Technical Specifications:
A.Temperature range of high & low temperature storage zone:
1.High temperature storage zone : RT to 200 Deg C
2.Low temperature storage zone : RT to - 55 Deg C
B. Temperature range of testing zone:
1.high temperature range : 60 to 150 Deg C
2.low temperature range : -10 to -10 Deg C
C. Analysis accuracy : 0.1 Deg C
D. Control accuracy : (+/-)0.5 Deg C ; uniformity : (+/-)2.0 Deg C% (100 Deg C); (+/-)3.0 Deg C%(150 Deg C)
E. Heating time of Heat-Storing zone: RT~200 Deg C,approx 75 mins
F. Cooling time of cooling-storing zone: RT~ -55 Deg C,approx 90 mins
G. Temperature Recovery Time of testing zone: in 5 mins (high or low temperature (constant temperature) shock time above 30 mins )
H. Machine's structure and material:
1.Interior dimension : 400 X350 X 350 MM (W x H x D)
2.Exterior dimension:1400 X 1800 X 1400 MM (W x H x D)
3. Structure:high temperature zone, low temperature zone, testing zone
4. Internal material : SUS#304 hardy heat-resistant stainless steel
5. Outter shell material : SUS#304 SUS#304 hardy heat-resistant stainless steel
Standards comply with:
GB/T 2431.1-2001 Testing A: Low temperature testing method
GB/T 2431.2-2001 Testing B: High temperature testing method
GJB 150.3-1986: High temperature
GJB 150.4-1986: Low temperature
IEC68-2-1 Test A: Cold
IEC68-2-2 Test A: Dry
GB 11158 High and low temperature test term
GB/T 2423.2 << Electrolic products basic environmental test: B: high temperature method>>
Control system:
1 Touch Screen controller:
2 Temperature controller: Using imported 7 inches microcomputer colorful LCD touch screen, direct touch type, the wide viewing angle, high contrast features programmable controller, with 120 set of programs, each program has a 13,000 circulation English said each cycle longest running time has 99H59M, along with multiple sets of PID control functions.
3 Controller Specifications:
3.1: Accuracy: ± 0.1 Deg C+1digit.
3.2: Resolution: ± 0.1 Deg C
3.3: Temperature slope: 0.1~9.9 programable
3.4: Having upper and lower standby and alarm functions
3.5: With Signal: PT100
3.6: Group 9 P.I.D control parameter setting, P.I.D automatic calculation."
49 Liters Touch Screen Cold Thermal Shock Chamber with Stainless Steel Material Saftey device:
5.1 Cooling System: Compressor heat loading or cold over loading warming
5.2 Testing room: Testing room and Humidifier temperature over loading warming.
5.3 Others: Leakage protection. Heating, dry protection. Overload, short circuit protection.Power protection.
Power: AC380V 3phase 5lines 50/60HZ
Company Details
Business Type:
Manufacturer
Year Established:
1988
Total Annual:
10000000-12000000
Employee Number:
100~120
Ecer Certification:
Active Member
ASLi (China) Test Equipment Co., Ltd is authenticated by competent testing centers, including the National Measurement andTestingCenterand South China Center of Metrology. Famous for precision and reliability, these products have been extensively used within the industry, by research institutions, q... ASLi (China) Test Equipment Co., Ltd is authenticated by competent testing centers, including the National Measurement andTestingCenterand South China Center of Metrology. Famous for precision and reliability, these products have been extensively used within the industry, by research institutions, q...
Get in touch with us
Leave a Message, we will call you back quickly!