China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel
China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel

  1. China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel
  2. China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel
  3. China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel
  4. China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel
  5. China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel
  6. China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel
  7. China Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel

Envsin 40KW Air Cooled Cyclic Corrosion Test Chamber Cold Rolled Steel

  1. MOQ: 1
  2. Price: USD
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union
Supply Ability 35 per month
Delivery Time 45 days
Packaging Details Well packed in strong wooden case suitable for all types of long distance shipment
Product Name Gas Test Chamber
Application Corrosion Testing
The test volume 3.3m³
Maximum operating power 40KW
Maximum running current 80A
Cooling Method Air cooled (refrigerating unit)
Outer chamber material cold rolled steel plate + double-sided electrostatic spraying process
Inner chamber material PVC plastic board
Brand Name Envsin
Model Number EQF2330
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union Supply Ability 35 per month
Delivery Time 45 days Packaging Details Well packed in strong wooden case suitable for all types of long distance shipment
Product Name Gas Test Chamber Application Corrosion Testing
The test volume 3.3m³ Maximum operating power 40KW
Maximum running current 80A Cooling Method Air cooled (refrigerating unit)
Outer chamber material cold rolled steel plate + double-sided electrostatic spraying process Inner chamber material PVC plastic board
Brand Name Envsin Model Number EQF2330
Certification CE Place of Origin China
High Light Envsin cyclic corrosion test chamber40KW cyclic corrosion test chamber40KW noxious gas test chamber

H2S,SO2,NO2,CI2 Cyclic Gas Test Chamber Gas Corrosion Testing Equipment

 

       The gas test chamber can meet the hydrogen sulfide, sulfur dioxide, chlorine gas, nitrogen dioxide test and other environmental test results; According to the requirements of the test, the accelerated corrosion of the material or product is carried out to test the damage degree of the material or product in a certain time range, so as to assess the corrosion resistance of the material and its protective layer.

 

Specification:
Gas Test Chamber Technical Parameters (Product Model:EQF2330)
Temperature test
Temperature range:20℃~+45℃
Remark:
 
1. Test in accordance with GB/T2423 and IEC60068 under empty chamber 
condition (except indicated).
 
2. The test data of the water-cooled test chamber are under the conditions that the water temperature is less than 28, the water pressure is between 0.3Mpa and 0.6Mpa, and the water pressure difference between inlet and outlet is more than 0.2Mpa.
Temperature uniformity:≤2.0℃
Temperature deviation:≤±2.0℃
Temperature fluctuation:≤±0.5℃
Temperature rate:≥1℃/min
Temperature and humidity climatic test

Humidity temperature control range:20℃~+50℃

Humidity range:50%RH~85%RH

Humidity uniformity:±5.0%RH
Humidity deviation: +2.0%~3%RH(>75%RH)±5%R.H(≤75%RH)
Humidity fluctuation:±5.0%RH

 

Gas concentration

5ppb~30ppm

The deviation of gas concentration in the chamber shall not exceed 10% of the set concentration,

Concentration uniformity deviation of 10%

The empty chamber operation request meets the IEC60068-2-60 standard

Gas concentration measurement

By calculating the volume ratio and then through the mass flowmeter measurement

On load capacity

500W,The temperature can be stable, the chamber body is not deformed
Noise
Working noise ≤70dB (measured at 1 meter away from the test chamber)
Wind speed
≤1.7m/s
Gas flowmeter H2S,SO2,NO2,CI2

 

 

Standard:
GB/T 2423.1-2001 / (IEC60068-2-1:2007)
Test A: Low temperature test method
GB/T 2423.2-2001 / (IEC60068-2-2:2007)
Test B: High temperature test method
GB/T 2423.3-2006 / (IEC60068-2-78:2007)
Test Cab: Constant humidity and heat test
GB/T 2423.4-2008 / (IEC60068-2-30:2005)
Test Db: alternating humidity and heat test
GJB 150.3-1986 / GJB 150.3A-2009
High-temperature test
GJB 150.4-1986 / GJB 150.4A-2009
Low temperature test
GJB 150.9-1986 / GJB 150.9A-2009
Thermal-humidity test
IEC60068-2-60
Test Method KE: Man-made low concentration pollution gas corrosion test
GB/T2423.51-2000
Environmental testing of electrical and electronic products Test KE: Flow mixed gas corrosion test

 

Gas corrosion system:

Operating Principle

Gas test chamber design two sets of boxes, external temperature and humidity air conditioning cabinet + sample room. The air conditioning system has refrigeration system, heating system, humidification system, mixed gas inlet, exhaust gas discharge filter and other devices.

 

Before diluting corrosive gases are mixed, the air conditioning system creates the test temperature and humidity in the chamber outside the sample room. When the temperature and humidity are constant, the gas is input at the same time. The gas concentration is measured by calculating the volume ratio formula, and then the mass flowmeter is used for effective control, so that it reaches the specified range. In the gas test chamber, the gas is mixed evenly through the fan.

 

Wet air into the sample chamber

The air in the sample room is discharged by pumping, so that a low pressure is formed in the sample room. Compared with the space in the sample room outside the gas test chamber, the wet air in the sample room outside is pumped into the sample room through the pipe. By recording the data, the flow rate of the air extracted from the sample chamber can be adjusted to obtain the specified number of gas volume changes per hour.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2005

  • Total Annual:

    $2.5 Million-US$5 Million

  • Employee Number:

    >500

  • Ecer Certification:

    Verified Supplier

For over 20 years, Envsin has been a trusted provider of environmental simulation and reliability testing solutions. We’ve served more than 170 Fortune 500 companies and over 1,000 small and medium-sized enterprises across 37 countries worldwide. Our expertise spans the development and pr... For over 20 years, Envsin has been a trusted provider of environmental simulation and reliability testing solutions. We’ve served more than 170 Fortune 500 companies and over 1,000 small and medium-sized enterprises across 37 countries worldwide. Our expertise spans the development and pr...

+ Read More

Get in touch with us

  • Reach Us
  • Envsin Instrument Equipment Co., Ltd.
  • 139, Yinxing Technology Building, No. 1235, Guangguang Road, Xinlan Community, Guanlan Street, Longhua District, Shenzhen
  • https://www.climatictestingchamber.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement