| Payment Terms | L/C,T/T,Western Union |
| Supply Ability | 10000 set per year |
| Delivery Time | 5-8 Work day |
| Packaging Details | carton |
| Operating frequency | 100KHz |
| Product Category | Cold Plasma System |
| Grade | 0~9 grade adjustable |
| Plasma technology | Specific waveform of electricity through the dual-pole or multi-pole probe in the human body to stimulate blood, mucosal and soft tissue or nucleus pulposus in the sodium chloride (Nacl) molecules to generate plasma state. Then the plasma high-speed charge |
| Maximum output power | ≤350W |
| Input voltage | 220V, 50Hz |
| Product Name | Portable ENT RF Ablation Cold Plasma System For Cutting Ablation Coagulation |
| Brand Name | Better Health |
| Model Number | cp-100 |
| Certification | CE |
| Place of Origin | china |
View Detail Information
Explore similar products
90 Degrees Arthroscopy RF Plasma Wand Surgical Equipments Shoulder Hip Knee
40-70 Celsius Arthroscopy RF Plasma Wand Surgical Equipments for Shoulder Hip
Arthroscopy RF Plasma Wand Surgical Equipments Shoulder Hip Knee Cruciate
4 Channels Arthroscopy RF Plasma Wand Surgical Equipments Shoulder Hip Knee 3
Product Specification
| Payment Terms | L/C,T/T,Western Union | Supply Ability | 10000 set per year |
| Delivery Time | 5-8 Work day | Packaging Details | carton |
| Operating frequency | 100KHz | Product Category | Cold Plasma System |
| Grade | 0~9 grade adjustable | Plasma technology | Specific waveform of electricity through the dual-pole or multi-pole probe in the human body to stimulate blood, mucosal and soft tissue or nucleus pulposus in the sodium chloride (Nacl) molecules to generate plasma state. Then the plasma high-speed charge |
| Maximum output power | ≤350W | Input voltage | 220V, 50Hz |
| Product Name | Portable ENT RF Ablation Cold Plasma System For Cutting Ablation Coagulation | Brand Name | Better Health |
| Model Number | cp-100 | Certification | CE |
| Place of Origin | china | ||
| High Light | 100 KHz portable cold plasma surgery system ,transurethral bladder tumor resection probe ,cold plasma arthroscope surgery probe | ||
The 100 KHz Portable Cold Plasma Surgery System is specially designed for transurethral resection of bladder tumors in minimally invasive urology procedures. This portable cold plasma surgery system delivers stable 100 KHz radio frequency energy to generate low-temperature plasma for precise tumor removal. The system enables accurate cutting, ablation, and coagulation while minimizing thermal injury to surrounding bladder tissue.
With compact structure and portable configuration, the 100 KHz portable cold plasma surgery system provides flexible use in operating rooms and endoscopic surgical environments. The cutting and coagulation in one design improves surgical efficiency during transurethral resection of bladder tumors and enhances intraoperative hemostasis.
The system adopts advanced radio frequency cold plasma technology operating at 100 KHz. The high-frequency energy ionizes conductive fluid to create a plasma layer at the electrode tip. This plasma field breaks molecular bonds in bladder tumor tissue, enabling smooth resection. Compared with conventional TUR electrosurgery, the portable cold plasma surgery system reduces carbonization and limits thermal spread.
During transurethral resection of bladder tumors, the plasma electrode is introduced through a resectoscope. The generator outputs 100 KHz RF energy to produce a localized plasma layer. The energized plasma particles dissolve tumor tissue at molecular level, while coagulation mode seals blood vessels simultaneously. This ensures controlled tumor removal with minimal bleeding.
| Parameter | Specification |
|---|---|
| Frequency | 100 KHz |
| Technology | RF Cold Plasma |
| Application | Bladder Tumor Resection |
| Procedure | Transurethral Surgery |
| Output Mode | Cutting / Coagulation / Ablation |
| Design | Portable System |
| Compatibility | Urology Resectoscope |
| Working Temperature | 40–70°C |
Q1: Is this system suitable for TURBT procedures?
Yes, the 100 KHz portable cold plasma surgery system is designed for transurethral resection of bladder tumors.
Q2: Does it support cutting and coagulation?
Yes, the device integrates cutting, ablation, and coagulation functions.
Q3: What is the benefit of portable design?
The portable structure allows flexible use in different surgical environments.
Q4: Does cold plasma reduce thermal damage?
Yes, low-temperature plasma technology minimizes collateral tissue injury.
![]()
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Trading Company
Year Established:
2008
Total Annual:
1000000-2000000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
DAMAI TECH CO .,LIMITED(Vayway Medical) Founded in 2008, DAMAI TECH has established itself as a leading manufacturer and supplier of innovative surgical solutions. Our portfolio encompasses a wide range of cutting-edge products, including the Plasma Surgery System, Cold Plasma En... DAMAI TECH CO .,LIMITED(Vayway Medical) Founded in 2008, DAMAI TECH has established itself as a leading manufacturer and supplier of innovative surgical solutions. Our portfolio encompasses a wide range of cutting-edge products, including the Plasma Surgery System, Cold Plasma En...
Get in touch with us
Leave a Message, we will call you back quickly!