Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Low Temperature Percutaneous Plasma Electrode For Nucleus Pulposus Ablation And","imgUrl":"https:\/\/img.chinax.com\/nimg\/4a\/bd\/4d13a789ca228a8fd07491b96cd8-200x200-1\/low_temperature_percutaneous_plasma_electrode_for_nucleus_pulposus_ablation_and.jpg","attrs":{"Power Output Settings":"Default Level","Warrantyperiod":"2 years","Usage":"Urinary treatment","Arthroscopy Rf Wands":"Arthroscopy Shaving System"}}
{"title":"Hemispherical Plasma Spine Probe for Intervertebral Foramen Endoscope","imgUrl":"https:\/\/img.chinax.com\/nimg\/bd\/9c\/3f15ca039f60069709007194ca60-200x200-1\/hemispherical_plasma_spine_probe_for_intervertebral_foramen_endoscope.jpg","attrs":{"Brand Name":"Better\/Vanway","Certification":"CFDA,ISO,CE","Place of Origin":"CHINA","Minimum Order Quantity":"1 piece"}}
{"title":"RF Surgical Spine Probe for Precise Disc Compression and Decompression","imgUrl":"https:\/\/img.chinax.com\/nimg\/e9\/a8\/178ea8435d2687f6420c81c76a9b-200x200-1\/rf_surgical_spine_probe_for_precise_disc_compression_and_decompression.jpg","attrs":{"Brand Name":"Better\/Vanway","Model Number":"VD17G","Certification":"CFDA,ISO,CE","Place of Origin":"CHINA"}}
{"title":"Relieving Pressure Plasma Spine Surgery Probe For Cervical And Lumbar Disc","imgUrl":"https:\/\/img.chinax.com\/nimg\/c5\/9a\/b7130c01cde879503ac0cc4c36a4-200x200-1\/relieving_pressure_plasma_spine_surgery_probe_for_cervical_and_lumbar_disc_decompression.jpg","attrs":{"Brand Name":"Better Health","Model Number":"ss-100","Certification":"CE,ISO","Place of Origin":"China"}}
{"title":"Plasma Spinal Wand Spondylitis Treatment Probe For Intervertebrale Endoscope","imgUrl":"https:\/\/img.chinax.com\/nimg\/46\/1d\/9f0c088699342e81e33ac9dd3850-200x200-1\/plasma_spinal_wand_spondylitis_treatment_probe_for_intervertebrale_endoscope.jpg","attrs":{"Brand Name":"Better Health","Model Number":"ss-100","Certification":"CE,ISO","Place of Origin":"CHINA"}}
{"title":"Plasma Backbone Surgical Spine Operation Probe For Minimally Invasive Cervical","imgUrl":"https:\/\/img.chinax.com\/nimg\/21\/22\/770bd8000fa7dbf5d8a043c9cfba-200x200-1\/plasma_backbone_surgical_spine_operation_probe_for_minimally_invasive_cervical_and_lumbar_disc.jpg","attrs":{"Brand Name":"Better Health","Model Number":"ss-100","Certification":"CE,ISO","Place of Origin":"China"}}
{"title":"Low Temperatur Plasma Spine Operation Probe for Intradiscal Pressure Reduction","imgUrl":"https:\/\/img.chinax.com\/nimg\/3c\/d9\/c261e9556ecba135be6e822bc90f-200x200-1\/low_temperatur_plasma_spine_operation_probe_for_intradiscal_pressure_reduction.jpg","attrs":{"Brand Name":"Better Health","Model Number":"ss-100","Certification":"CE,ISO","Place of Origin":"China"}}
The Low Temperature Percutaneous Plasma Electrode For Nucleus Pulposus Ablation And Puncture Surgery is designed for minimally invasive spine procedures requiring precise disc decompression and controlled tissue ablation. This electrode is specially developed for percutaneous puncture techniques used in lumbar and cervical disc herniation treatment. It enables accurate nucleus pulposus removal while minimizing damage to surrounding neural structures.
Using advanced low temperature plasma technology, the electrode creates a focused plasma field at the tip, allowing targeted vaporization and shrinkage of nucleus pulposus tissue. The controlled ablation reduces intradiscal pressure in real time and relieves nerve root compression. The percutaneous design supports smooth insertion and precise positioning during minimally invasive puncture surgery.
This percutaneous plasma electrode is widely used in disc decompression procedures, providing stable performance, reduced surgical trauma, and faster patient recovery.
Characteristics
Percutaneous puncture surgical design
Low temperature plasma ablation
Precise nucleus pulposus removal
Minimally invasive operation
Stable plasma energy output
Reduced thermal injury risk
Smooth insertion and positioning
Technology
The electrode adopts low temperature plasma ablation technology. A high-frequency electric field ionizes conductive medium to generate plasma energy. The plasma breaks molecular bonds in soft tissue, allowing controlled tissue dissolution at relatively low temperature.
This technology enables safe nucleus pulposus shrinkage while preserving surrounding annulus fibrosus and neural structures. It also improves surgical precision during minimally invasive puncture procedures.
Working Principle
After percutaneous puncture access is established, the electrode is inserted into the intervertebral disc. Plasma energy is generated at the working tip, causing molecular dissociation of nucleus pulposus tissue.
The ablated tissue is vaporized and shrinks, leading to reduced disc volume. As intradiscal pressure decreases, compression on nerve roots and surrounding tissues is relieved. The procedure achieves decompression with minimal bleeding and limited thermal spread.
Application
Nucleus pulposus ablation
Percutaneous puncture surgery
Lumbar disc herniation treatment
Cervical disc herniation treatment
Minimally invasive disc decompression
Intervertebral disc pressure reduction
Advantages
Designed for percutaneous puncture procedures
Low working temperature 40–70°C
Accurate nucleus pulposus ablation
Reduced nerve damage risk
Minimally invasive surgical trauma
Fast decompression effect
Stable and reliable performance
Short recovery time
Technical Parameters
Parameter
Specification
Product Type
Percutaneous Plasma Electrode
Application
Nucleus Pulposus Ablation
Surgical Method
Percutaneous Puncture
Working Temperature
40–70°C
Function
Ablation And Decompression
Suitable Area
Lumbar And Cervical Disc
Sterile
Yes
Use
Single Use
Service
We provide OEM and ODM customization services. Electrode length, diameter, working tip structure, cable length, and connector type can be customized. Technical support and product training are available.
FAQ
Q1: What procedures is this electrode used for? It is used for percutaneous puncture surgery and nucleus pulposus ablation in disc herniation treatment.
Q2: What technology does it use? It uses low temperature plasma ablation technology.
Q3: Is it suitable for minimally invasive surgery? Yes, it is specifically designed for minimally invasive puncture procedures.
Q4: Can specifications be customized? Yes, customization is supported.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Trading Company
Year Established:
2008
Total Annual:
1000000-2000000
Employee Number:
150~200
Ecer Certification:
Verified Supplier
DAMAI TECH CO .,LIMITED(Vayway Medical) Founded in 2008, DAMAI TECH has established itself as a leading manufacturer and supplier of innovative surgical solutions. Our portfolio encompasses a wide range of cutting-edge products, including the Plasma Surgery System, Cold Plasma En...
DAMAI TECH CO .,LIMITED(Vayway Medical) Founded in 2008, DAMAI TECH has established itself as a leading manufacturer and supplier of innovative surgical solutions. Our portfolio encompasses a wide range of cutting-edge products, including the Plasma Surgery System, Cold Plasma En...