China factories

Chat Now Send Email
China factory - Shenzhen Coolstart Refrigeration Equipment Co., Ltd

Shenzhen Coolstart Refrigeration Equipment Co., Ltd

  • China,Shenzhen ,Guangdong
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China Refcomp SRC-S(W)-603 SRC-S-603-L4 R410a Refrigeration Screw Compressor
China Refcomp SRC-S(W)-603 SRC-S-603-L4 R410a Refrigeration Screw Compressor

  1. China Refcomp SRC-S(W)-603 SRC-S-603-L4 R410a Refrigeration Screw Compressor
  2. China Refcomp SRC-S(W)-603 SRC-S-603-L4 R410a Refrigeration Screw Compressor
  3. China Refcomp SRC-S(W)-603 SRC-S-603-L4 R410a Refrigeration Screw Compressor

Refcomp SRC-S(W)-603 SRC-S-603-L4 R410a Refrigeration Screw Compressor

  1. MOQ: 1
  2. Price: Discussed
  3. Get Latest Price
Rated Power 220HP/164KW
Application HVAC, Condensing Unit, Cold Room, Rack System
Delivery Time 1 Month
Packaging Details WOODEN CASE
Payment Terms Western Union,T/T
Oil Charge 20L
Displacement 50/60Hz 600/720 m3/hr
Refrigerant R22, R407C, R410a, R404A, R507A
Supply Ability 100000Pcs/Year
Model Number SRC-S(W)-603,SRC-S-603-L4
Certification CE
Brand Name Refcomp
Place of Origin China

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Rated Power 220HP/164KW Application HVAC, Condensing Unit, Cold Room, Rack System
Delivery Time 1 Month Packaging Details WOODEN CASE
Payment Terms Western Union,T/T Oil Charge 20L
Displacement 50/60Hz 600/720 m3/hr Refrigerant R22, R407C, R410a, R404A, R507A
Supply Ability 100000Pcs/Year Model Number SRC-S(W)-603,SRC-S-603-L4
Certification CE Brand Name Refcomp
Place of Origin China
High Light Refcomp SRC-S-603 R410a Compressor ,SRC-S(W)-603 Refrigeration Screw Compressor ,Refcomp SRC-S-603-L4 Screw Compressor
Product Description
  • High-Efficiency Asymmetric Rotor Profile: Optimized 5/6 lobe geometry ensures smooth, quiet meshing and continuous gas displacement for demanding refrigeration applications.
  • Integrated Internal Oil Separator: Multi-stage internal separation reaches up to 99.85% efficiency, minimizing oil carryover and maintaining clean heat exchanger surfaces.
  • Flexible Capacity Modulation: Supports 4-step capacity control (100%, 75%, 50%, 25%) alongside full stepless modulation to match variable thermal loads precisely.
  • Advanced Motor Thermal Protection: Equipped with an INT69 SNY module and six series-connected PTC thermistors for continuous real-time monitoring of motor winding and discharge temperatures.
Product Image
Refcomp class=
Technical Specification
Model class="lazy" src="/myres/images/load_icon.gif" data-original-S(W)-603 class="lazy" src="/myres/images/load_icon.gif" data-original-S-603-L4
Rated power 220HP / 164KW
Exhaust volume (50Hz / 60Hz) 700 / 840 m³/hr
Refrigerant Type R22, R407C, R410a, R404A, R507A
Weight 1020 KG
Oil Charge 20 L
Voltage 400/3/50Hz – 460/3/60Hz
Cooling Capacity Regulation 100%, 75%, 50%, 25% (stepless 100%–25%)
LRA Y/Δ 543 / 1645A 595 / 1802A
Refcomp class=
FAQ
Q: What electrical supply requirements and heater ratings must be accommodated in the control panel for the class="lazy" src="/myres/images/load_icon.gif" data-original-S(W)-603 (class="lazy" src="/myres/images/load_icon.gif" data-original-S-603-L4) compressor?

A: The main motor operates on a standard 400V/3Ph/50Hz or 460V/3Ph/60Hz power supply, while the built-in crankcase heater requires a dedicated 275W – 230V – 50/60Hz supply to prevent refrigerant migration during idle periods.

Q: What piping layout factors should be considered when connecting suction and discharge lines to this model?

A: Installers must match the 105.5 mm (4-1/8") suction connection and 80.0 mm (3-1/8") discharge line accurately, ensuring proper support and vibration isolation to eliminate excessive stress on the shut-off valves.

Q: How should the oil level and initial lubrication be verified prior to commissioning?

A: Check that the oil charge reaches the specified level visible in the sight glass using the approved lubricant type (such as S001 for R22 or S002 for HFC blends), and verify filter cleanliness before startup.

Q: What diagnostic steps should technicians follow if the INT69 SNY module triggers a safety lockout?

A: Inspect motor winding and discharge gas temperature sensors, verify correct three-phase supply voltage sequence, check for phase imbalance, and ensure adequate cooling superheat before resetting the module.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2001

  • Total Annual:

    50000000-10000000

  • Employee Number:

    30~100

  • Ecer Certification:

    Verified Supplier

Shenzhen Coolstart Refrigeration Equipment Co., Ltd. is a modern, professional refrigeration manufacturer with over 20 years of industry experience. We focus on the professional production and global sales of high-performance refrigeration equipment, serving as a reliable and cost-effective suppli... Shenzhen Coolstart Refrigeration Equipment Co., Ltd. is a modern, professional refrigeration manufacturer with over 20 years of industry experience. We focus on the professional production and global sales of high-performance refrigeration equipment, serving as a reliable and cost-effective suppli...

+ Read More

Get in touch with us

  • Reach Us
  • Shenzhen Coolstart Refrigeration Equipment Co., Ltd
  • Room 1801, Building 1, Kangli city, No. 66 Pingji Road, Longgang District, Shenzhen, Guangdong,China
  • https://www.coldroomunit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement