| Contact Plating | 锡 |
| Number of Rows | 1 |
| Pitch | 2mm |
| Description | Connector Through Hole 2mm |
| Mfr. Part # | 10KR-D6S-P |
| Package | P=2mm |
| Model Number | 10KR-D6S-P |
View Detail Information
Explore similar products
2 mm IDC Wiremount Socket 3M 37304-A165-0PE MB Mini-Clamp II Series with
Versatile JST 03SR-3S connector designed for disconnectable wire termination in
Wire To Board Connector DLL XG-20A Featuring 2.54 Millimeter Pitch And Multiple
mini clamp socket 3M 37308-3101-0W0 FL with plug latch acceptance and UL 94V-0
Product Specification
| Contact Plating | 锡 | Number of Rows | 1 |
| Pitch | 2mm | Description | Connector Through Hole 2mm |
| Mfr. Part # | 10KR-D6S-P | Package | P=2mm |
| Model Number | 10KR-D6S-P |
The KRD connector is a 2.0 mm pitch disconnectable insulation displacement connector, designed as an alternative to the NRD connector for printed circuit boards. It facilitates daisy chaining, simplifying connection systems in electronic equipment. Key features include a twin slot insulation displacement section, distortion-resistant construction, interchangeability, and a low profile design.
| Model No. | No. of circuits | Current rating | Voltage rating | Temperature range | Contact resistance (max.) | Insulation resistance (min.) | Withstanding voltage | Applicable wire | Applicable PC board thickness | Q'ty/ box |
|---|---|---|---|---|---|---|---|---|---|---|
| 02KR-D8M-P | 2 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 2,000 |
| 03KR-D8M-P | 3 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 2,000 |
| 04KR-D8M-P | 4 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 2,000 |
| 05KR-D8M-P | 5 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 06KR-D8M-P | 6 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 07KR-D8M-P | 7 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 08KR-D8M-P | 8 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 09KR-D8M-P | 9 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 10KR-D8M-P | 10 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 11KR-D8M-P | 11 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 12KR-D8M-P | 12 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 13KR-D8M-P | 13 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 14KR-D8M-P | 14 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 15KR-D8M-P | 15 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 16KR-D8M-P | 16 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 02KR-D6S-P | 2 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 2,000 |
| 03KR-D6S-P | 3 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 2,000 |
| 04KR-D6S-P | 4 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 2,000 |
| 05KR-D6S-P | 5 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 06KR-D6S-P | 6 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 07KR-D6S-P | 7 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 08KR-D6S-P | 8 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 1,000 |
| 09KR-D6S-P | 9 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 10KR-D6S-P | 10 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 11KR-D6S-P | 11 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 12KR-D6S-P | 12 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 13KR-D6S-P | 13 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 14KR-D6S-P | 14 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 15KR-D6S-P | 15 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
| 16KR-D6S-P | 16 | 1.0 A AC, DC (AWG #26) | 100 V AC, DC | -25 to +85 | Initial: 10 m, After env. tests: 20 m | 1,000 M | 800 VAC/minute | UL1571, UL1061 (AWG #28, #26) | 0.8 to 1.6 mm | 500 |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer
Year Established:
2009
Total Annual:
10000000-50000000
Employee Number:
300~500
Ecer Certification:
Verified Supplier
Your Trusted Source for Integrated Circuit Shenzhen ECER Network Technology Co., Ltd. is a professional company focus on integrated circuit ic business. ECER connects buyers worldwide with verified manufacturers across 40+ industries. Every component sourced with precision, quality, and reliability... Your Trusted Source for Integrated Circuit Shenzhen ECER Network Technology Co., Ltd. is a professional company focus on integrated circuit ic business. ECER connects buyers worldwide with verified manufacturers across 40+ industries. Every component sourced with precision, quality, and reliability...
Get in touch with us
Leave a Message, we will call you back quickly!