Suzhou Huajing Air-Condition Purification Engineering Installation Co., Ltd.
| Payment Terms | L/C,T/T |
| Packaging Details | Wooden Case, Galvanized Steel Pallet, Plastic Film |
| Delivery Time | 30 days |
| Supply Ability | ≥1 set |
| Product name | Air Handling Unit AHU |
| Applicable Industries | Manufacturing Plant |
| Type | air cooled heat exchanger tower |
| Warranty | 1 Year |
| Dimension(L*W*H) | custom |
| Key Selling Points | Automatic |
| Core Components | Motor |
| Application | Lab |
| Function | Cooling\Heating |
| Refrigerant | R134a |
| Keyword | Cooling Air-cooled AHU Ducted |
| Brand Name | SHP |
| Model Number | Customized |
| Certification | CE,ISO |
| Place of Origin | Jiangsu, China |
View Detail Information
Explore similar products
CE ISO9001 Air Handling Unit Duct Ahu For Electronics Industry Cleanroom Project
Central AC Modular Ahu Air Handler Combined Hydronic Air Customizable Air Flow
12.6kW Central Air Handling Unit Ac Air Handler LCD Screen Cleaning Ac Air
70000m3/H Industrial Ahu Air Handling Systems CEC Air Handlers Heating & Cooling
Product Specification
| Payment Terms | L/C,T/T | Packaging Details | Wooden Case, Galvanized Steel Pallet, Plastic Film |
| Delivery Time | 30 days | Supply Ability | ≥1 set |
| Product name | Air Handling Unit AHU | Applicable Industries | Manufacturing Plant |
| Type | air cooled heat exchanger tower | Warranty | 1 Year |
| Dimension(L*W*H) | custom | Key Selling Points | Automatic |
| Core Components | Motor | Application | Lab |
| Function | Cooling\Heating | Refrigerant | R134a |
| Keyword | Cooling Air-cooled AHU Ducted | Brand Name | SHP |
| Model Number | Customized | Certification | CE,ISO |
| Place of Origin | Jiangsu, China | ||
| High Light | Clean Room Axial Fan 2000m3/H ,ahu unit 70000m3/H ,air handlers hvac custom | ||
![]()
Multi-Stage System: Pre-filters (G4/F5) → Medium-efficiency (F7/F8) → Terminal HEPA/ULPA (>99.99% @ 0.3/0.12 µm).
Performance Monitoring: Differential pressure sensors track filter loading for predictive maintenance.
High Airflow: Delivers very high air change rates for rapid contaminant dilution.
Advanced Control: Employs CAV/VAV valves and VFD fans for dynamic air balance.
Pressure Cascades: Maintains defined pressure gradients (e.g., +15 Pa, +10 Pa) to enforce unidirectional airflow and zone isolation.
Tight Tolerances: Maintains stability within narrow bands (e.g., ±0.5°C, ±5% RH).
Deep Conditioning: Uses deep cooling/desiccant dehumidification and clean-steam humidification.
Reheat Requirement: Essential for temperature correction post-dehumidification; a major energy consumer.
Airtight Design: Prevents infiltration of untreated air.
Sanitary Interiors: Smooth, crevice-free, corrosion-resistant materials (e.g., stainless steel).
Dry Design: Sloped condensate pans ensure complete drainage to prevent microbial growth.
Heat Recovery: Incorporates enthalpy wheels or plate heat exchangers to reduce cooling/heating loads by preconditioning outside air, lowering operational costs.
![]()
Mixing Box Section
Function: To mix outdoor fresh air (Outside Air) with recirculated indoor air (Return Air) in a controlled ratio to maintain indoor air quality and energy efficiency.
Key Components: Motorized dampers for outside, return, and exhaust air, often interlocked for proper pressure control.
Filtration Section
Function: To remove airborne particulates (dust, pollen, microbes).
Filter Types:
Pre-filters (G3-G4): Protect downstream coils and components.
Medium-efficiency filters (F5-F8): Used in offices, hospitals, and general commercial spaces.
High-efficiency filters (HEPA, ULPA): Used in cleanrooms, operating theaters, and critical environments.
Thermal Conditioning Section
Function: The core for controlling air temperature and moisture.
Key Components:
Cooling Coil: Uses chilled water (e.g., 6°C supply, 12°C return) or direct-expansion refrigerant to cool and dehumidify air.
Heating Coil: Uses hot water, steam, or electric heating elements to heat air.
Humidifier: Adds moisture. Common types: Dry steam injectors, adiabatic humidifiers (e.g., high-pressure mist), and electrode/ resistive steam humidifiers.
Fan Section
Function: Provides the mechanical energy to move air through the unit and the entire duct system. It is the "heart" of the AHU.
Key Types: Centrifugal fans (forward or backward curved).
Configuration: Draw-through (fan after coils, preferred for even air distribution and coil drainage) or blow-through (fan before coils).
Control: Almost always equipped with a Variable Frequency Drive (VFD) for variable airflow and energy savings.
Auxiliary Sections
Sound Attenuators: Lined sections or silencers to reduce fan and airflow noise.
Heat Recovery Section: Devices like enthalpy wheels, plate heat exchangers, or run-around coils to recover energy from exhaust air and precondition incoming outside air, significantly improving efficiency.
Plenum / Flow Straightener: Ensures uniform airflow across filters and coils.
![]()
As a leading supplier of clean room system and clean room products,SHP is an organization that prides itself both on technical expertise as well as next level customer care.SHP offers Cleanroom Solutions to meet our clients' particular requirements specialized for pharmaceutical,biotechnology and microelectronic cleanrooms.We also provide a range of Clean Room products including wall panel,door&window and a series of clean room equipment.
As an ISO 9001:2015 certified organization,we are committed to continually improving our customer service programs while meeting or exceeding your product quality criteria.With our comprehensive customer solution offerings,excellence in products,and decades of technical expertise,we are confident that SHP can match the best to your application.
![]()
![]()
Q1: Where is your company?
A1:Our company is located in Suzhou City, close to Shanghai. It's a 1.5-hour drive from PVG Airport.
Q2: Are you a manufacturer or a trading company? What can I buy from you?
A2: We are manufacturers. We focus on cleanroom projects, air showers, FFUs, through boxes, dosing rooms, laminar flow hoods and benches, AHUs, and sealed doors and Windows.
Q3:When is your delivery time?
A3: If your cleanroom project includes AHU, the delivery time is 35 days. If you purchase goods without an AHU, the delivery time is 10 days.
Q4: How long is your warranty period? What kind of after-sales service can you offer?
A4: Our warranty period is two years after the completion of the project. During the warranty period, if there are any problems, we will replace it. If you can't handle it, we will send an engineer to solve it for free.
Q5:Can you conduct cleanroom validation?
A5: Yes, we can offer documentaries of DQ, IQ, OQ and PQ. Still fat & Sitting. Product operation manual, maintenance guide and a complete set of cleanroom drawings.
Q6:What are your advantages?
A6: We have a complete technical team consisting of 12 senior cleanroom and HVAC engineers to provide you with technical support. We have completed over 2,100 cleanroom projects in China and overseas. Such as Japan, Indonesia, Thailand, Bangladesh, India, North Macedonia, Saudi Arabia, Yemen, Russia, Moldova, Switzerland, Norway, the United Kingdom, Spain, France, Belgium, Kuwait, Tunisia, Mauritius, Sri Lanka, Mongolia, Philippines, Nepal, Sudan, Somaliland, Australia, New Zealand, Canada, Algeria, Egypt, Singapore, and the United States.
Company Details
Business Type:
Manufacturer,Exporter,Trading Company,Seller
Year Established:
2003
Total Annual:
4000000-5000000
Employee Number:
20~50
Ecer Certification:
Verified Supplier
Established in 2003 20+ years cleanroom experience 10000+SQ.M workshop Main products:Cleanroom,HVAC,Air Shower, FFU,Pass Box,HEPA Box,Clean Bench,LAF,Cleanroom Door, Cleanroom Window,Sandwich Panel Established in 2003 20+ years cleanroom experience 10000+SQ.M workshop Main products:Cleanroom,HVAC,Air Shower, FFU,Pass Box,HEPA Box,Clean Bench,LAF,Cleanroom Door, Cleanroom Window,Sandwich Panel
Get in touch with us
Leave a Message, we will call you back quickly!