Model: | Cubtm102A |
Battery type: | Rechargeable |
Voltage: | 10.8V |
Capacity: | 4.4Ah |
Input power: | 100-240V,50-60HZ,1.4A |
Output power: | 18V,5.8A,104.4W 12V,0.5A,6.0W |
Delivery: | DHL or others |
Package: | Carton |
View Detail Information
Explore similar products
Corrosion Resistant Overcharge Resistant No Memory Effect Ni-MH Battery
12V 2.8Ah LiMnO2 Medical Batteries Rechargeable 4-07-0001 HYB 18-0075 For
Rechargeable Li-ion Battery NT-LI4S1P-PA for ECG Patient Monitor 14.8V 38.48Wh
Inogen One G4 BA-408 14.4V 6.5Ah 93.6Wh Rechargeable Lithium Ion Medical Battery
Product Specification
Payment Terms | T/T,Western Union,PayPal | Packaging Details | Carton Package |
Product Name: | Battery | Model: | Cubtm102A |
Battery type: | Rechargeable | Voltage: | 10.8V |
Capacity: | 4.4Ah | Input power: | 100-240V,50-60HZ,1.4A |
Output power: | 18V,5.8A,104.4W 12V,0.5A,6.0W | Delivery: | DHL or others |
Package: | Carton | ||
High Light | 10.8V Medical Defibrillator Battery ,4.4Ah CU-HD1 Battery ,300-500 Charge Cycles Cubtm102A Battery |
Replacement battery for Cubtm102A Cu-HD1 medical defibrillator CU-HD1 batteries for medical equipment
This replacement battery for the Cubtm102A and Cu-HD1 medical defibrillator lead wires is designed specifically for the Cubtm102A and Cu-HD1 medical defibrillator lead wires. It features a rated voltage of 14.8V, a capacity of 4.2Ah, and an energy density of approximately 62.16Wh. The battery dimensions are precisely measured to match the physical specifications of the original battery. It also includes a built-in proprietary communication protocol chip, enabling accurate identification by the defibrillator, preventing "uncertified battery" errors. This core function replaces the original battery of the same model, ensuring proper function of the lead wires.
Product Features
1. Powers the Cu-HD1 defibrillator, ensuring it provides automated external defibrillation, manual defibrillation, synchronized cardioversion, transcutaneous pacing, and patient monitoring functions.
2. When the defibrillator's main battery is low or suddenly loses power, the battery provides power to critical signal monitoring functions for approximately 30 minutes, preventing ECG data loss due to power outages and allowing emergency personnel more time to respond.
Product Name | Battery |
REF | Cubtm102A |
Type | Rechargeable |
Input power | 100-240V,50-60HZ,1.4A |
Output power | 18V,5.8A,104.4W 12V,0.5A,6.0W |
Packing | 1pc/box |
Condition | New Original |
Battery Life | 300-500 times |
Size | 169x104x50mm |
Weight | 585g |
Color | White |
Q1: After the battery is fully charged, is it normal for the battery to drop to 70% after only one short ECG monitoring session (approximately 10 minutes)? A1: If the defibrillator's main unit uses high-power functions during monitoring, a 30% battery consumption in 10 minutes is normal. If only basic functions are enabled, the battery may be experiencing capacity degradation. You can test the battery by installing it in another device. If the same problem persists, replace the battery.
Q2: Can this battery be charged with a mobile phone charger or a charger from another brand of defibrillator?
A2: Absolutely not. The output voltage of a mobile phone charger doesn't match the battery's requirements. Forced charging can cause over-discharge or damage the battery cells. The charging protocols of other brands of defibrillator chargers are incompatible with this battery, potentially resulting in incomplete charging, overheating, and even safety risks. You must use the original Cubtm102A/Cu-HD1 charger or a certified charger specifically for this battery.
Q3: After long-term storage, I noticed a slight white powder on the surface of this battery. Can I continue to use it?
A3: It cannot be used. This is a sign of battery leakage. The white powder is a compound formed when the electrolyte inside the battery cell leaks and reacts with air. If it continues to be used, the leakage may corrode the battery compartment contacts, causing equipment failure or even causing a short circuit and damaging the defibrillator.
Company Details
Ecer Certification:
Verified Supplier
China World Technology Battery Service Group: Powering the Future with Premium Batteries Company History The history of China World Technology Battery Service Group can be traced back to early 2015, when the company was relatively small and only focused on producing basic lead-acid batteries. Due ... China World Technology Battery Service Group: Powering the Future with Premium Batteries Company History The history of China World Technology Battery Service Group can be traced back to early 2015, when the company was relatively small and only focused on producing basic lead-acid batteries. Due ...