Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"LC1D65ABD Schneider Electric TeSys D 65A DC Coil Contactor Original","imgUrl":"https:\/\/img.chinax.com\/nimg\/0a\/45\/c39db315e39cdcee3e67e7915edd-200x200-1\/lc1d65abd_schneider_electric_tesys_d_65a_dc_coil_contactor_original.jpg","attrs":{"Express Delivery":"DHL (default) \/ FedEx \/ UPS \/ TNT \/ Air \/ Sea","Payment Terms":"T\/T,Alipay,Paypal","Condition":"Brand new and original","Model Number":"LC1D65ABD"}}
{"title":"GVAE11 Schneider Electric TeSys Deca Manual Starter and Protector auxiliary","imgUrl":"https:\/\/img.chinax.com\/nimg\/ef\/5f\/2d3f48decec4bbdf4a731d85afd1-200x200-1\/gvae11_schneider_electric_tesys_deca_manual_starter_and_protector_auxiliary_contact_block.jpg","attrs":{"Brand Name":"Schneider Electric","Model Number":"GVAE11","Certification":"COO & COC","Place of Origin":"Germany"}}
{"title":"GVAD0110 Schneider Electric TeSys Deca - auxiliary contact - 1 NO + 1 NC","imgUrl":"https:\/\/img.chinax.com\/nimg\/b4\/95\/b1fcfe93a5cbb4e3c5a6ecba3046-200x200-1\/gvad0110_schneider_electric_tesys_deca_auxiliary_contact_1_no_2b_1_nc.jpg","attrs":{"Brand Name":"Schneider Electric","Model Number":"GVAD0110","Certification":"COO & COC","Place of Origin":"Germany"}}
{"title":"GV2ME32 Schneider Electric Motor circuit breaker TeSys GV2 3P 24-32 A thermal","imgUrl":"https:\/\/img.chinax.com\/nimg\/2a\/0d\/d0e13784a5ffc9eaa1061f1981c9-200x200-1\/gv2me32_schneider_electric_motor_circuit_breaker_tesys_gv2_3p_24_32_a_thermal_magnetic.jpg","attrs":{"Brand Name":"Schneider Electric","Model Number":"GV2ME32","Certification":"COO & COC","Place of Origin":"Germany"}}
{"title":"GV2ME20 Schneider Electric TeSys GV2-Circuit breaker-thermal-magnetic - 13...18","imgUrl":"https:\/\/img.chinax.com\/nimg\/3d\/69\/30bbcdae016de9b456a45af30118-200x200-1\/gv2me20_schneider_electric_tesys_gv2_circuit_breaker_thermal_magnetic_13_18_a.jpg","attrs":{"Brand Name":"Schneider Electric","Model Number":"GV2ME20","Certification":"COO & COC","Place of Origin":"Germany"}}
{"title":"GV2ME16 Schneider Electric Motor circuit breaker, TeSys GV2 3P 9-14 A thermal","imgUrl":"https:\/\/img.chinax.com\/nimg\/90\/a4\/a9e6f9eab6fcad8e9b67a091226d-200x200-1\/gv2me16_schneider_electric_motor_circuit_breaker_2c_tesys_gv2_3p_9_14_a_thermal_magnetic.jpg","attrs":{"Brand Name":"Schneider Electric","Model Number":"GV2ME16","Certification":"COO & COC","Place of Origin":"Germany"}}
{"title":"GV2ME14 Schneider Electric TeSys GV2-Circuit breaker-thermal-magnetic - 6...10 A","imgUrl":"https:\/\/img.chinax.com\/nimg\/81\/64\/2f2c0d924eca6864ee8eea898bee-200x200-1\/gv2me14_schneider_electric_tesys_gv2_circuit_breaker_thermal_magnetic_6_10_a.jpg","attrs":{"Brand Name":"Schneider Electric","Model Number":"GV2ME14","Certification":"COO & COC","Place of Origin":"Germany"}}
Typical Uses: PLC-driven motor control, energy-efficient panels, silent-running HVAC systems.
Common Field Issues:
Coil fails to hold below 19 VDC → check PSU ripple and wiring drop
Aux contact chatter under vibration → tighten mounting screws to spec
Note: "BD" suffix denotes integrated electronic protection; not interchangeable with standard "B7" AC coil variant.
Related products
LC1D65AB7C
LC1D65AM7C
LC1D50ABD
LC1D80ABD
LC1D40ABD
LC1D95ABD
LC1D38ABD
LC1D32ABD
LC1D25ABD
LC1D18ABD
LC1D12ABD
LC1D09ABD
LC1D65ABDL
LC1D65ABDT
LC1D50ABDL
LC1D80ABDL
LC1D40ABDL
LC1D95ABDL
LC1D38ABDL
LC1D32ABDL
FAQ
Q1: What does the "ABD" suffix mean in LC1D65ABD? A: "A" = base frame size, "B" = 24 VDC coil voltage, "D" = low-power DC type with built-in reverse-polarity diode and snubber — designed for direct PLC transistor output without external relay.
Q2: Can LC1D65ABD replace a standard LC1D65B7 AC coil contactor? A: Electrically compatible for same load ratings, but coil supply must change from 24 VAC to 24 VDC; control circuit rewiring required. Physical dimensions and mounting are identical.
Q3: Is LC1D65ABD suitable for switching resistive heating loads? A: Yes, rated 100 A under AC-1 category; ensure proper thermal management inside enclosure when operating near full resistive current continuously.
We are a global trading company specializing in PLC automation and industrial controls.
Xiamen Changxuyuan Trading Co., Ltd. is a leading global online wholesale supplier, offering a wide selection of new and discontinued products. We are committed to providing a wide range of high-quality products... We are a global trading company specializing in PLC automation and industrial controls.