Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Sand-vik DD\/DL accumulator gas valve80759069","imgUrl":"https:\/\/img.chinax.com\/nimg\/7c\/2f\/0a36bed8317fcda97abf61f27f4e-200x200-1\/sand_vik_dd_2fdl_accumulator_gas_valve80759069.jpg","attrs":{"Safety Features":"Emergency Stop, Overload Protection, Fire Suppression","Payment Terms":"T\/T","Supply Ability":"9999","Bucket":"2.2 cubic meter"}}
{"title":"Sand-vik Grinding Wheel Protective Cap Model 5000-08, Mount Hole Diameter 8mm","imgUrl":"https:\/\/img.chinax.com\/nimg\/c9\/6c\/e152e1cb85145e09a6b019a038c3-200x200-1\/sand_vik_grinding_wheel_protective_cap_model_5000_08_2c_mount_hole_diameter_8mm.jpg","attrs":{"Mounting Inner Diameter":"8 mm","Model Number":"5000-08","Minimum Order Quantity":"1","Delivery Time":"15days"}}
{"title":"Deionization Module EDI IP-VNX55EP-2","imgUrl":"https:\/\/img.chinax.com\/nimg\/43\/c1\/525b059059cc5463bd6aef4faf2f-200x200-1\/deionization_module_edi_ip_vnx55ep_2.jpg","attrs":{"Price":"1746850","Packaging Details":"Original packaging","Model":"IP-VNX55EP-2","Place of Origin":"USA"}}
{"title":"Epiroc Part No. 2300000498 Windshield Washer Pump","imgUrl":"https:\/\/img.chinax.com\/nimg\/be\/72\/11ad0aea6dbc67a0ba2a15c13f1f-200x200-1\/epiroc_part_no_2300000498_windshield_washer_pump.jpg","attrs":{"Model Number":"2300000498","Supply Ability":"9999","Output Pressure":"0.7\u20131.0 bar, sufficient pressure for long-distance fluid delivery inside cab piping","Net Weight":"0.13 kg per unit"}}
Emergency Stop, Overload Protection, Fire Suppression
Payment Terms
T/T
Supply Ability
9999
Bucket
2.2 cubic meter
Width
37--88mm
Delivery Time
15days
Battery Life
: >500 cycle time
Power Source
Diesel/Electric
Packaging Details
Original packaging
Power Frequency
50HZ-60HZ
Tar Adhesive Weight
20t
Adhesive Weight
8
Shape
U Channel
Engine Model
490
Type
Heavy Machinery
Noise Db
73
Bucket Cap
0.3m3
Min Application Section
17 m3
Thickness
4.5-9.5mm
Model Number
80759069
Place of Origin
CHINA
Brand Name
Sand-vik
Sand-vik 80759069 Accumulator Gas Charging Valve
Part No. 80759069 is an original nitrogen charging valve (also called gas filling valve / pressure retaining valve) for Sand-vik DD/DL series underground development drill rigs and longhole drill rigs. It is used for nitrogen filling, pressure detection and pressure sealing of hydraulic accumulators. This original part features a compact threaded structure with a yellow protective cap.
1. Basic Information
Part Number: 80759069 (Full code: 807 590 69)
Brand: Sand-vik
Type: Accumulator Gas Charging Valve
Applicable Models:
DD Series: DD2100, DD2710, DD3110, DD422iE and other underground development drill rigs
DL Series: DL2100, DL2710 and other longhole drill rigs
Other Equipment: Accumulator circuits of TB40, TB60 and RD520 hydraulic rock drills
Function: Serves as the exclusive port for nitrogen charging and pressure testing of accumulator gas chamber, and maintains pressure by sealing.
2. Core Functions
Nitrogen filling: Connect with nitrogen cylinder and charging tools to fill high-pressure nitrogen into the accumulator. Standard pre-charge pressure: 80–100 bar.
Pressure detection: Connect external pressure gauge to monitor nitrogen pressure for routine maintenance and calibration.
Pressure sealing: Built-in one-way sealing structure automatically closes after charging to prevent nitrogen leakage and keep stable system pressure.
Overload protection: Releases pressure slightly under abnormal overpressure to protect accumulator shell and hydraulic components.
3. Key Specifications
Max Working Pressure: 350 bar, suitable for high-pressure hydraulic systems
Applicable Gas: High-purity nitrogen (N₂)
Thread Type: Standard metric external thread for direct installation on accumulator
Valve Body Material: High-strength carbon steel with anti-rust treatment
Seal Material: FKM fluoroelastomer, featuring high pressure resistance, oil resistance and high temperature resistance
Operating Temperature: -30℃ ~ +120℃
Weight: Approximately 0.056 kg
Appearance: Silver metal valve body with yellow plastic protective cap for anti-collision and dust prevention
4. Appearance & Structure
Overall structure: Compact cylindrical threaded valve. One end with external thread for mounting on accumulator, and the other end is gas charging port fitted with yellow protective cap.
Internal structure: Composed of one-way spool, spring and sealing assembly. The spool is pushed open during charging and closes automatically to achieve sealing.
Original marking: Part number 80759069 and Sand-vik logo engraved on valve body. The protective cap is designed to prevent loss.
5. Replacement & Compatibility
Genuine part: 80759069 is the only standard model with no alternative upgraded parts.
Interchangeability: Not compatible with similar valves of Epiroc and Atlas Copco due to different port sizes and thread specifications.
Installation Position: Gas port on the top of hydraulic accumulator, applied for hydraulic stations and rock drill accumulator assemblies of DD/DL drill rigs.
6. Common Faults & Maintenance
Air leakage / Pressure loss: Caused by aging seals, worn spool or impurities entering due to missing protective cap. Solution: Replace the whole valve and check the protective cap regularly.
Failed gas charging: Caused by stuck spool or damaged thread. Solution: Clean the port or replace with a new valve.
Maintenance Schedule: Check gas pressure every 500 working hours; replace the charging valve every 1000 working hours to avoid leakage caused by component aging.