China Yokogawa ET5-B Universal Thermocouple Input Signal Conditioner Card
China Yokogawa ET5-B Universal Thermocouple Input Signal Conditioner Card

  1. China Yokogawa ET5-B Universal Thermocouple Input Signal Conditioner Card
  2. China Yokogawa ET5-B Universal Thermocouple Input Signal Conditioner Card
  3. China Yokogawa ET5-B Universal Thermocouple Input Signal Conditioner Card

Yokogawa ET5-B Universal Thermocouple Input Signal Conditioner Card

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Supply Ability in stock
Delivery Time 2-3 work days
Packaging Details Brand new and original
Payment Terms T/T
Place of Origin JAPAN
Brand Name Yokogawa

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Supply Ability in stock Delivery Time 2-3 work days
Packaging Details Brand new and original Payment Terms T/T
Place of Origin JAPAN Brand Name Yokogawa
High Light Yokogawa ET5B ,Universal Thermocouple Input Card ,ET5-B pdf
Yokogawa Signal Conditioning

ET5-B

Universal Thermocouple Input Signal Conditioner
Request a Quote Share the full card label and controller model for identification.
INPUT CARD PROFILE
ThermocoupleTemperature signal input
8 TC TypesB / E / J / K / T / R / S / N
SC MAINTController-based configuration
PRODUCT CLASS ET5*B /A02
Yokogawa identifies ET5*B as a universal thermocouple input signal-conditioning card for the YS150 multifunction loop controller and YS170 programmable controller. The controller manual lists it under input option /A02.

Technical Specifications

ET5*B model-specific information
YOKOGAWA ET5-B / THERMOCOUPLE INPUT MODEL DATA & CONFIGURATION
01 / Product Identification
Manufacturer Yokogawa
Model designation in YS150/YS170 manual ET5*B
Input option /A02
Product function Universal thermocouple input signal-conditioning card
Documented controller family YS100 Series: YS150 / YS170
Input signal Thermocouple
02 / Thermocouple Input & Measurement Setup
Supported thermocouple types B, E, J, K, T, R, S and N
Engineering units Degrees C, F or K
Input zero Configurable through the SC MAINT menu
Input span Configurable through the SC MAINT menu
Burnout selection OFF, UP or DOWN
Wiring resistance compensation Wiring R parameter compensates for errors associated with high thermocouple wire resistance and burnout current
Input compensation Zero adjustment and span adjustment are available
03 / Controller Communication & Monitoring
Configuration interface YS150 / YS170 SC MAINT display
Card communication Controller menu communicates with the signal-conditioning card
Model identification Installed card model name can be displayed
Input value Displayed in configured engineering units
Output value Displayed as a percentage
Self-check GOOD or ERROR result
Revision information Card software revision number can be displayed
04 / Detailed Configuration Parameters
B06 / T/C Type Selects B, E, J, K, T, R, S or N thermocouple input
B09 / Unit Selects degrees C, F or K
B10 / Zero Sets the input range zero point
B11 / Span Sets the input span; span is the upper input range minus the zero point
B12 / Burn Out Selects OFF, UP or DOWN
C03 / Wiring R Compensates for errors associated with high thermocouple wire resistance and burnout current
C04 / Zero Adj. Increases, decreases or resets input compensation for the A/D converter
C05 / Span Adj. Increases, decreases or resets input compensation for the A/D converter

Model details above follow Yokogawa's YS100 Series installation and operation manual. Confirm the complete suffix and controller configuration before ordering.

Configuration & Installation Notes

Controller menu · input setup · field wiring

SC MAINT Configuration

For the YS150/YS170 arrangement documented in the manual, ET5*B is the /A02 universal thermocouple input option. Card parameters are accessed through the controller's SC MAINT display.

  • Enable the SC MAINT communication function.
  • Establish communication with the installed signal-conditioning card.
  • Set the thermocouple type and engineering unit.
  • Set the input zero and span to the required measurement range.
  • Select the required burnout behavior: OFF, UP or DOWN.
  • Review wiring resistance compensation and input zero/span adjustment when required.

Controller Interface

The direct-input arrangement depends on the controller model and its configured process-variable path.

  • For YS150, the manual describes the direct-input signal conversion and the required connection from terminals 9 and 10 to the process-variable input at terminals 1 and 2.
  • For YS170, the process-variable assignment depends on the custom program configuration.
  • Verify the controller terminal assignment and wiring diagram before changing field connections.
Do not assume that a card with a similar ET5 designation has the same controller interface. Check the complete card marking, controller model and input option before replacement.

Application & Failure Scenarios

Temperature measurement · loop control · maintenance

Thermocouple-Based Process Monitoring

ET5*B is documented as a universal thermocouple input option for Yokogawa YS150 multifunction loop controllers and YS170 programmable controllers. It is used where a thermocouple measurement is required as a controller input for temperature indication and configured process-control functions.

Maintenance Search Triggers

01Temperature input is missing, unstable or inconsistent with the field measurement.
02The controller's SC MAINT self-check displays ERROR.
03The thermocouple type, unit, zero, span or burnout setting needs to be checked after maintenance.
04The signal-conditioning card is suspected of causing an incorrect temperature value.
If the temperature input is unavailable or unreliable, the related indication, alarm and control loop may be affected. The actual process and shutdown impact depends on the controller strategy, interlocks and plant control design.

Supply & Warranty

Inspection · packing · order support
Inspection & Testing Inspection and available test arrangements confirmed with the quotation.
Protective Packaging Protective packing for industrial electronic components.
DOA / Returns Report arrival faults or transit damage promptly with order details and photos.
12-Month Warranty Coverage subject to the agreed quotation and warranty terms.

Global Industrial Sourcing

Part identification · international supply · order coordination
AMIKON industrial automation sourcing and service team
AMIKON / GLOBAL INDUSTRIAL TRADE Connecting Automation Parts with Global Industry.
AMIKON INDUSTRIAL SUPPLY

Practical Sourcing for Industrial Maintenance

AMIKON supports industrial maintenance and procurement teams with automation component sourcing, part identification, order coordination and international shipment arrangements.

Product Enquiry

Talk to Our Sales Team

Contact Miya Zheng for product and order enquiries.

DIRECT CONTACT / MIYA ZHENG sales@amikon.cn WhatsApp +86 180 2077 6792
RFQ details: Part Number  ·  Quantity  ·  Destination  ·  Required Date  ·  Machine/System Model

Frequently Asked Questions

Yokogawa ET5-B
1. What is the function of the Yokogawa ET5-B?

Yokogawa's YS150/YS170 manual identifies ET5*B as a universal thermocouple input signal-conditioning card used with input option /A02.

2. Which thermocouple types are supported?

The documented selectable thermocouple types are B, E, J, K, T, R, S and N.

3. Can the temperature unit and burnout behavior be configured?

Yes. The documented settings include degrees C, F or K, together with burnout selections OFF, UP or DOWN.

4. How is the ET5*B configured in a YS150 or YS170 controller?

The controller manual describes using the SC MAINT display to communicate with the card and configure thermocouple type, engineering unit, zero, span and related adjustment parameters.

5. What should be checked before ordering a replacement?

Check the complete card marking, controller model, installed input option and existing configuration. The ET5 designation alone should not be used to assume that different suffix or controller variants are interchangeable.

Related Models

Additional sourcing references

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Trading Company

  • Year Established:

    2004

  • Total Annual:

    85682000-125000000

  • Employee Number:

    70~80

  • Ecer Certification:

    Verified Supplier

Company Profile Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems. Product scope includes: ➢Distributed Control Syste... Company Profile Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems. Product scope includes: ➢Distributed Control Syste...

+ Read More

Get in touch with us

  • Reach Us
  • AMIKON LIMITED
  • 32D units,GuoMao Building No 388 Hubin South Road Siming district Xiamen, Fujian China
  • https://www.dcscontroller.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement