{"title":"Allen-Bradley 1746-OW16 Relay Output Module \u2013 16-Point AC\/DC Relay Output for","imgUrl":"https:\/\/img.chinax.com\/nimg\/24\/63\/1959729ad499a1385472c31fc1a9-200x200-1\/allen_bradley_1746_ow16_relay_output_module_e2_80_93_16_point_ac_2fdc_relay_output_for.jpg","attrs":{"Place of Origin":"USA","Packaging Details":"Brand new and original","Minimum Order Quantity":"1","Payment Terms":"T\/T"}}
{"title":"Allen Bradley 1746-OA16 SLC 500 16-Point 120\/240V AC Output Module","imgUrl":"https:\/\/img.chinax.com\/nimg\/82\/ea\/cc51b92468aaef361f6b5beb0980-200x200-1\/allen_bradley_1746_oa16_slc_500_16_point_120_2f240v_ac_output_module.jpg","attrs":{"Delivery Time":"2-3 work days","Model Number":"1746-OA16","Platform":"SLC 500","Payment Terms":"T\/T"}}
{"title":"Allen Bradley 1606-XLE240EE 240W DIN-Rail Power Supply 24V DC 10A","imgUrl":"https:\/\/img.chinax.com\/nimg\/c8\/7c\/980d345beb5b8f9a0c475fc7096c-200x200-1\/allen_bradley_1606_xle240ee_240w_din_rail_power_supply_24v_dc_10a.jpg","attrs":{"Packaging Details":"Brand new and original","Brand Name":"Allen Bradley","Product Type":"240 W industrial DC power supply","Model Number":"1606-XLE240EE"}}
{"title":"Allen Bradley 2711P-T6M20D PanelView Plus 600 Monochrome Touch HMI with EtherNet","imgUrl":"https:\/\/img.chinax.com\/nimg\/71\/e0\/4f4c4a0f5a35e317803524349388-200x200-1\/allen_bradley_2711p_t6m20d_panelview_plus_600_monochrome_touch_hmi_with_ethernet_2fip.jpg","attrs":{"Delivery Time":"2-3 work days","Brand Name":"Allen Bradley","Product Type":"PanelView Plus 600 monochrome touch terminal","Minimum Order Quantity":"1"}}
{"title":"Allen Bradley 2711PC-T10C4D1 PanelView Plus Compact 1000 Color Touch Terminal","imgUrl":"https:\/\/img.chinax.com\/nimg\/6e\/3e\/3e144878b4851b61f508b2b021b7-200x200-1\/allen_bradley_2711pc_t10c4d1_panelview_plus_compact_1000_color_touch_terminal.jpg","attrs":{"Delivery Time":"2-3 work days","Product Type":"10-inch color touch operator terminal","Brand Name":"Allen Bradley","Platform":"PanelView Plus Compact 1000"}}
Relay switching for established SLC 500 installations.
The 1746-OW16 provides 16 relay output points for control circuits using AC or DC field power. It is relevant to maintenance teams troubleshooting switching failures or sourcing a module for an existing control cabinet.
Technical Specifications
Key electrical and hardware characteristics
Platform SLC 500Output Relay contactsChannels 16 pointsContact type Normally openAC operating range 5–265 V ACAC frequency 47–63 HzDC operating range 5–125 V DCCommon grouping 8 points per common5 V backplane draw 170 mA24 V backplane draw 180 mALifecycle Discontinued Nov. 24, 2022
Additional electrical ratings and hardware details +
Inductive load 1.5 A per output at 120 V ACInductive load 1.2 A per output at 24 V DCModule current limit 16 A totalCommon current limit 8 A per commonContinuous power ceiling 1440 VA per moduleContact arrangement Two groups of eight outputsRelay designators K1–K16Isolation 500 V DC, communication circuits
The output load ratings are not interchangeable across voltage and load types. Check the connected load, inrush and inductive characteristics, group current, and total module loading before energizing a circuit.
Application & Failure Scenarios
Machine control: Relay outputs switch field devices in existing SLC 500 control systems where the connected circuit requires a relay contact rather than a transistor output.
Output not switching: A commanded output that fails to change state can prompt checks of the control logic, field supply, terminal wiring, relay contact path and connected load.
Intermittent operation: Unstable switching may interrupt a machine sequence or process step. The symptom alone does not establish whether the module, field circuit or controlled device is responsible.
Downtime exposure: Loss of an output channel may stop the equipment function assigned to it; the wider production impact depends on the machine's control sequence and operating conditions.
Installation & Field Wiring
Power isolation: Switch off chassis power before installing, removing, or wiring the module. Never remove the terminal block while the SLC 500 system is energized.
Chassis fitting: Align the module circuit board with the chassis card guide, slide it into position until the lower locking tabs engage, and route wiring down and away from the module, securing it neatly.
Terminal handling: Colored terminal blocks are removable after loosening the upper and lower retaining screws; black terminal blocks are not removable. Keep conductors and terminal hardware secure during maintenance.
Wiring limits: Use conductors up to 2 mm² (14 AWG), no more than two wires per terminal, and a maximum terminal torque of 0.9 N·m (8 lb-in). Terminal-block retaining screws have a maximum torque of 0.6 N·m (5.3 lb-in).
Noise and static control: Route field wiring carefully to reduce electrical noise. Discharge static before handling, use an approved grounding wrist strap, avoid touching pins or circuit components, and use static-safe packaging for storage.
Cabinet protection: Install the open-type module inside a suitable enclosure. Cover unused chassis slots with the designated slot filler to limit debris entry.
Troubleshooting Priorities
Verify the output commandCheck field voltageInspect terminal connectionsConfirm common groupingReview load currentCheck contact switching and load condition
For relay-output faults, distinguish between a missing command, a field power or wiring issue, a failed load, and a relay contact that no longer switches reliably. Remove power and follow the machine's lockout procedure before inspecting terminals or conductors.
Supply · Inspection · After-sales
Testing: Available inspection and functional-test arrangements are confirmed before order.
Packaging: Protective packaging is selected for the confirmed item condition and shipment.
Returns / DOA: Report suspected arrival damage or functional failure promptly with order details and evidence. Return approval and remedies follow the agreed sales terms.
Warranty: The applicable coverage period, scope and exclusions are stated in the quotation or order confirmation.
PERSONAL SUPPORT FOR INDUSTRIAL PARTS
Let's Keep Your System Moving.
Clear communication for sourcing, order details and technical part identification.
Part Number · Quantity · Destination · Required Date · Machine/System Model
Frequently Asked Questions
1. What is the 1746-OW16 used for?
It is a 16-point relay output module in the Allen-Bradley SLC 500 family for switching AC or DC field circuits through relay contacts.
2. Is the 1746-OW16 discontinued?
Yes. Rockwell Automation lists the product as discontinued, effective November 24, 2022. Sourcing should therefore be based on the actual available item and its confirmed condition.
3. What should I check if an output stops working?
Check the controller command, field supply, terminal wiring, load condition and relay contact operation. A failed output symptom does not by itself prove that the module is defective.
4. Can another 16-point output module replace it directly?
Not necessarily. Output technology, voltage range, contact arrangement, common grouping, wiring and the controller platform must all be assessed before a replacement is selected.
Related Models · Browse the catalog number collection
Reference models from the supplied catalog pool. Inclusion here does not indicate compatibility or direct replacement for the 1746-OW16.
AMIKON INDUSTRIAL SUPPLY · INDUSTRIAL PARTS SOURCING · CUSTOMER SUPPORT
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Trading Company
Year Established:
2004
Total Annual:
85682000-125000000
Employee Number:
70~80
Ecer Certification:
Verified Supplier
Company Profile
Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems.
Product scope includes:
➢Distributed Control Syste... Company Profile
Amikon Limited specializes in the global supply of industrial automation module spare parts.The company focuses on well-known international brands covering DCS systems, robot control systems, and large-scale servo control systems.
Product scope includes:
➢Distributed Control Syste...