| Input Voltage | 3-Phase 380–480 VAC |
| Supply Ability | 10 Units per Month |
| Communication | EtherNet/IP |
| Payment Terms | T/T |
| Display | Numeric LCP 21 |
| Packaging Details | Anti-static Bag + Carton Box + Foam Protection |
| PCB Coating | Coated PCB Class 3C3 |
| Rated Power | 5.5 kW / 7.5 HP |
| Brake Chopper | Integrated |
| Enclosure | IP21 / Type 1 |
| RFI Filter | H2 / EMC Category C3 |
| Model Number | FC-280P5K5T4E21H2BNCXXXSXXXXAN |
| Brand Name | Danfoss |
| Place of Origin | Denmark |
View Detail Information
Explore similar products
Danfoss 134U2982 FC-280P2K2T4E20H1BXCXXXSXXXXAX VLT Midi Drive 2.2kW 380-480V
Danfoss 134U2979 FC-280PK75T4E20H1BXCXXXSXXXXAX VLT Midi Drive 0.75kW 380-480V
Danfoss 134U3015 FC-280P7K5T4E20H2BXCXXXSXXXXAX VLT Midi Drive 7.5kW 380-480V
Danfoss 134U2984 FC-280P4K0T4E20H1BXCXXXSXXXXAX VLT Midi Drive 4kW 380-480V IP20
Product Specification
| Input Voltage | 3-Phase 380–480 VAC | Supply Ability | 10 Units per Month |
| Communication | EtherNet/IP | Payment Terms | T/T |
| Display | Numeric LCP 21 | Packaging Details | Anti-static Bag + Carton Box + Foam Protection |
| PCB Coating | Coated PCB Class 3C3 | Rated Power | 5.5 kW / 7.5 HP |
| Brake Chopper | Integrated | Enclosure | IP21 / Type 1 |
| RFI Filter | H2 / EMC Category C3 | Model Number | FC-280P5K5T4E21H2BNCXXXSXXXXAN |
| Brand Name | Danfoss | Place of Origin | Denmark |
The Danfoss 135N1789 is an exact VLT Midi Drive FC 280 frequency-converter configuration identified by the complete type code FC-280P5K5T4E21H2BNCXXXSXXXXAN.
The unit is rated for 5.5 kW / 7.5 HP and operates from a three-phase 380-480 VAC supply. Unlike the IP20 chassis versions, this configuration uses an E21 IP21 / Type 1 enclosure suitable for installations requiring additional protection.
The drive includes an H2 RFI filter, brake IGBT, numeric LCP, coated PCB and integrated EtherNet/IP communication. These options make it suitable for networked industrial machines requiring local operation and Ethernet-based controller integration.
Relevant procurement searches include 135N1789, FC-280P5K5T4E21H2BNCXXXSXXXXAN, FC-280P5K5T4, Danfoss FC 280 5.5kW, FC 280 EtherNet/IP and VLT 2800 retrofit drive.
| Commercial Reference | 135N1789 |
| Complete Type Code | FC-280P5K5T4E21H2BNCXXXSXXXXAN |
| Product Series | VLT Midi Drive FC 280 |
| Product Type | Variable Frequency Drive |
| Rated Motor Power | 5.5 kW / 7.5 HP |
| Power Code | P5K5 |
| Voltage Code | T4 |
| Input Supply | 3-phase 380-480 VAC |
| Supply Frequency | 50/60 Hz |
| Motor Output | Three-phase adjustable voltage and frequency |
| Enclosure Code | E21 |
| Protection Rating | IP21 / Type 1 |
| RFI Filter Code | H2 |
| EMC Classification | Class A2 / C3 according to applicable installation conditions |
| Brake IGBT | Included |
| Local Control Panel | Numeric LCP 21 installed |
| PCB Protection | Coated PCB, Class 3C3 |
| Mains Option | No additional mains option |
| Integrated Fieldbus | EtherNet/IP |
| Network Application | Compatible with appropriately configured EtherNet/IP controllers |
| Safety Capability | Safe Torque Off platform functionality |
| Motor Compatibility | Asynchronous and permanent-magnet motors |
| Lifecycle Status | Active platform |
| Legacy Direction | Engineering replacement platform for selected VLT 2800 applications |
The 135N1789 is suitable for conveyors, pumps, fans, packaging systems, mixers, compressors and material-handling machines requiring EtherNet/IP communication. The installed numeric LCP supports local parameter access, status monitoring and commissioning.
When connecting the drive to an EtherNet/IP network, verify the PLC platform, device profile, IP addressing, control assembly, status words, safety architecture and required firmware compatibility.
The E21, H2 and AN sections of the type code are important. They identify the IP21 enclosure, H2 RFI filter and EtherNet/IP communication. A different 5.5 kW FC 280 configuration may not be electrically or mechanically equivalent.
For retrofit work, confirm the complete legacy model, rated current, duty class, brake resistor, communication network, terminal wiring, parameter backup, cabinet layout and motor data. A VLT 2800 replacement requires engineering review and recommissioning.
Related FC 280 power families include FC-280P4K0T4, FC-280P7K5T4 and FC-280P11KT4. Other 5.5 kW configurations may use E20 IP20 enclosures, H1 filters, no LCP or alternative fieldbus protocols.
For quotation, provide the complete nameplate, required quantity, destination, application, network protocol and condition requirement. Availability and delivery time must be confirmed against commercial reference 135N1789.
Company Details
Business Type:
Exporter,Trading Company,Seller
Year Established:
2024
Total Annual:
1000000-1500000
Employee Number:
10~25
Ecer Certification:
Site Member
Company Profile DF Automatic supplies industrial automation spare parts, control system components, and replacement parts to customers worldwide. Our product range covers PLC modules, servo drives, servo motors, variable frequency drives, HMI panels, industrial sensors, pneumatic components, h... Company Profile DF Automatic supplies industrial automation spare parts, control system components, and replacement parts to customers worldwide. Our product range covers PLC modules, servo drives, servo motors, variable frequency drives, HMI panels, industrial sensors, pneumatic components, h...
Get in touch with us
Leave a Message, we will call you back quickly!