| Payment Terms | L/C, D/A, D/P, T/T, Western Union |
| Supply Ability | 20PC |
| Delivery Time | in stock |
| Packaging Details | original packing |
| Brand Name | FLUKE |
| Model Number | 376 |
| Place of Origin | China |
View Detail Information
Explore similar products
100% New Clamp Meter With Card Type Multimeter Function Output Line Length 800mm
100% New And Original Weidmuller PRO ECO3 Switching Power Supply 480W 24V 20A
Yokogawa Handheld Process Calibrator CA300 Series Yokogawa CA310 CA320 CA330
Fluke 376FC 374FC 375FC 381 378 373 AC/DC Clamp Meter True-RMS Clamp Meter
Product Specification
| Payment Terms | L/C, D/A, D/P, T/T, Western Union | Supply Ability | 20PC |
| Delivery Time | in stock | Packaging Details | original packing |
| Brand Name | FLUKE | Model Number | 376 |
| Place of Origin | China | ||
| High Light | Fluke 376 Insulation Tester ,original Fluke 376 voltage meter ,Fluke 376 power meter with warranty | ||
| Electrical Specifications | ||||
| AC Current via Jaw | ||||
| Range | 374 and 375 376 |
600.0 A 999.9 A |
||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits (10-100 Hz) 2.5% ± 5 digits (100-500 Hz) |
|||
| Crest Factor (50/60 Hz) | 3 @ 500 A (375 and 376 only) 2.5 @ 600 A 1.42 @1000 A (376 only) Add 2% for C.F. > 2 |
|||
| AC Current via Flexible Current Probe | ||||
| Range | 2500 A | |||
| Resolution | 374 and 375 | 0.1 A (≤ 600 A) 1 A (≤ 2500 A) |
||
| 376 | 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) |
|||
| Accuracy | 3% ±5 digits (5 – 500 Hz) | |||
| Crest Factor (50/60Hz) | 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2 |
|||
| Distance from Optimum | i2500-10 Flex | i2500-18 Flex | Error | |
| A | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) | ± 0.5% | |
| B | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) | ± 1.0% | |
| C | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) | ± 2.0% | |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||||
| DC Current | ||||
| Range | 374 and 375 376 |
600.0 A 999.9 A |
||
| Resolution | 0.1 A | |||
| Accuracy | 2% ± 5 digits | |||
| AC Voltage | ||||
| Range | 374 and 375 376 |
600.0 V 1000 V |
||
| Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
| Accuracy | 1.5% ± 5 digits (20 – 500 Hz) | |||
| DC Voltage | ||||
| Range | 374 and 375 376 |
600.0 V 1000 V |
||
| Resolution | 374 and 375 376 |
0.1 V 0.1 V (≤ 600.0 V) 1 V (≤ 1000 V) |
||
| Accuracy | 1% ± 5 digits | |||
| mV dc | ||||
| Range | 375 and 376 | 500.0 mV | ||
| Resolution | 0.1 mV | |||
| Accuracy | 1% ± 5 digits | |||
| Frequency via Jaw | ||||
| Range | 375 and 376 | 5.0 - 500.0 Hz | ||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 – 10 Hz, ≥10 A | |||
| 10 – 100 Hz, ≥5 A | ||||
| 100 – 500 Hz, ≥10 A | ||||
| Frequency via Flexible Current Probe | ||||
| Range | 375 and 376 | 5.0 - 500.0 Hz | ||
| Resolution | 0.1 Hz | |||
| Accuracy | 0.5% ± 5 digits | |||
| Trigger Level | 5 – 20 Hz, ≥ 25 A | |||
| 20 – 100 Hz, ≥ 20 A | ||||
| 100 – 500 Hz, ≥ 25 A | ||||
| Resistance | ||||
| Range | 374 375 and 376 |
6000 Ω 60 kΩ |
||
| Resolution | 374 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) |
||
| 375 and 376 | 0.1 Ω (≤ 600 Ω) 1 Ω (≤ 6000 Ω) 10 Ω (≤ 60 kΩ) |
|||
| Accuracy | 1% ± 5 digits | |||
| Capacitance | ||||
| Range | 1000 μF | |||
| Resolution | 0.1 μF (≤ 100 μF) 1 μ F (≤ 1000 μF) |
|||
| Accuracy | 1% ± 4 digits | |||
| Mechanical Specifications | ||||
| Size (L x W x H) | 246 mm x 83 m x 43 mm | |||
| Weight | 388 g | |||
| Jaw Opening | 34 mm | |||
| Flexible Current Probe Diameter | 7.5 mm | |||
| Flexible Current Probe Cable Length (head to electronics connector) |
1.8 m | |||
| Environmental Specifications | ||||
| Operating Temperature | 10°C – +50°C | |||
| Storage Temp | -40°C – +60°C | |||
| Operating Humidity | Non condensing (< 10 –°C) ≤ 90% RH (at 10°C – 30°C) ≤ 75% RH (at 30°C – 40°C) ≤ 45% RH (at 40°C – 50°C) |
|||
| Operating Altitude | 3000 meters | |||
| Storage Altitude | 12,000 meters | |||
| EMC | EN 61326-1:2006 | |||
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C |
|||
| Safety Specifications | ||||
| Safety Compliance | CAN/CSA-C22.2 No. 61010-1-04 ANSI/UL 61010-1:2004 ANSI/ISA-61010-1 (82.02.01):2004 EN/IEC 61010-1:2001 to 1000V Measurement Category (CAT) III 600V Measurement Category (CAT) IV Pollution Degree 2 EN/IEC 61010-2-032:2002 EN/IEC 61010-031:2002+A1:2008 |
|||
| Agency Approvals | ||||
| Batteries | 2 AA, NEDA 15A, IEC LR6 | |||
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller
Year Established:
2013
Total Annual:
1000000-5000000
Employee Number:
30~60
Ecer Certification:
Verified Supplier
Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential... Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential...
Get in touch with us
Leave a Message, we will call you back quickly!