China factories

Chat Now Send Email
China factory - Mengchuan Instrument Co,Ltd.

Mengchuan Instrument Co,Ltd.

  • China,Wenzhou ,Zhejiang
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In
China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In

  1. China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In
  2. China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In
  3. China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In
  4. China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In
  5. China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In
  6. China New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In

New Original Multi-parameter Benchtop Photometer & pH Meter HANNA HI83300 - In

  1. MOQ: 1
  2. Price: USD$1598
  3. Get Latest Price
Delivery Time in stock
Packaging Details Original packaging
Supply Ability 10PC
Payment Terms L/C, D/A, D/P, T/T, Western Union
Model Number HI83300
Place of Origin China
Brand Name HANNA

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time in stock Packaging Details Original packaging
Supply Ability 10PC Payment Terms L/C, D/A, D/P, T/T, Western Union
Model Number HI83300 Place of Origin China
Brand Name HANNA
High Light original benchtop photometer pH meterHANNA HI83300 multi-parameter photometerhigh accuracy benchtop pH meter
GENERAL    
MEASUREMENT CHANNELS   5 X OPTICAL CHANNELS; 1 X SMART ELECTRODE CHANNEL (pH MEASUREMENT)
Absorbance Range   0.000Abs-4.000Abs
Absorbance Resolution   0.001 Abs
Absorbance Accuracy   ±0.003 Abs (at 1.000 Abs)
Absorbance Light Source   Light-emitting diode
Absorbance Bandpass Filter Bandwidth   8nm
Absorbance Bandpass Filter Wavelength Accuracy   ±1.0nm
Light Detector   Silicon photocell
Cuvette Type   round, 24.6 mm diameter
Number of Methods   128 max
pH Range   -2.00 to 16.00 pH (±1000mV)*
pH Resolution   0.01 pH (0.01 mV)*
Temperature Compensation   ATC (-5.0 to 100.0°C;*)
Additional Specifications:    
Logging   1000 readings (mixed photometer and electrode)
Display   128 x 64 pixel B/W LCD with backlight
USB-A (host) functions   mass-storage host
USB-B ( Device) Functions   power input, mass-storage device
Battery Life   >500 Photometer measurements, or 50 hours of continuous pH measurement
Power supply   5 VDC USB 2.0 power adapter/ type micro-B connector 3.7 VDC Li-polymer rechargeable battery, non-serviceable
Environment   0 to 50°C; 0 to 95% RH, non-condensing
Dimensions   206 x 177 x 97mm
Weight   1.0kg
Ordering Information   HI-83300 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
*Limits will be reduced to actual sensor limits    

 

ABSORBANCE

Absorbance Range   0.000 to 4.000 Abs
Absorbance Resolution   0.001 Abs
Absorbance Accuracy   +/-0.003Abs @ 1.000 Abs

 

ALKALINITY - Reagents - HI-93755-01 (100 tests); HI-93755-03 (300 tests)

Alkalinity Range   Freshwater: 0 to 500 mg/L (as CaCO3) Marine: 0 to 300 mg/L (as CaCO3)
Alkalinity Resolution   1 mg/L
Alkalinity Accuracy   ±5 mg/L ±5% of reading
Alkalinity Method   Colorimetric method

 

ALUMINIUM - Reagents - HI-93712-01 (100 tests); HI-93712-03 (300 tests)

Aluminium Range   0.00 to 1.00 mg/L (as Al3+)
Aluminium Resolution   0.01 mg/L
Aluminium Accuracy   ±0.04 mg/L ±4% of reading
Aluminium Method   Adaptation of the aluminon method

 

AMMONIA - Reagents: HR - HI-93733-01 (100 tests); HI-93733-03 (300 tests)
MR - HI-93715-01 (100 tests); HI-93715-03 (300 tests)
LR - HI-93700-01 (100 tests); HI-93700-03 (300 tests)

Ammonia Range   Low Range: 0.00 to 3.00 mg/L (as NH3-N) Medium Range: 0.00 to 10.00 mg/L (as NH3-N) High Range: 0.0 to 100.0 mg/L (as NH3-N)
Ammonia Resolution   0.01 mg/L; 0.1 mg/L
Ammonia Accuracy   Low Range: ±0.04 mg/L ±4% of reading Medium Range: ±0.05 mg/L ±5% of reading High range: ±0.5 mg/L ±5% of reading at 25 °C
Ammonia Method   Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method

 

ANIONIC SURFACTANTS

Anionic Surfactants Range   0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution   0.01 mg/L
Anionic Surfactants Accuracy   ±0.04 mg/L ±3% of reading
Anionic Surfactants Method   Adaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS.

 

BROMINE - Reagents: HI-93716-01 (100 tests); HI-93716-03 (300 tests)

Bromine Range   0.00 to 8.00 mg/L (as Br2)
Bromine Resolution   0.01 mg/L
Bromine Accuracy   ±0.08 mg/L ±3% of reading
Bromine Method   Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.

 

CALCIUM - Reagents: HI-937521-01 (50 tests); HI-937521-03 (150 tests)

Calcium Range   Freshwater: 0 to 400 mg/L (as Ca2+) Seawater: 200 to 600 mg/L (as Ca2+)
Calcium Resolution   1 mg/L
Calcium Accuracy   Freshwater: ±10 mg/L ±5% of reading Seawater: ±6% of reading
Calcium Method   Freshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method

 

CHLORIDE - Reagents: HI-93753-01 (100 tests); HI-93753-03 (300 Tests)

Chloride Range   0.0 to 20.0 mg/L (as Cl⁻)
Chloride Resolution   0.1 mg/L
Chloride Accuracy   ±0.5 mg/L ±6% of reading at 25 °C

 

CHLORINE DIOXIDE - Reagents: HI-93738-01 (100 tests); HI-93738-03 (300 tests)

Chlorine Dioxide Range   0.00 to 2.00 mg/L (as ClO2)
Chlorine Dioxide Resolution   0.01 mg/L
Chlorine Dioxide Accuracy   ±0.10 mg/L ±5% of reading
Chlorine Dioxide Method   Adaptation of the Chlorophenol Red method.

 

CHLORINE - Free Chlorine Reagents: HI-93701-01 (100 tests); HI-93701-03 (300 tests); HI-93701-F (liquid) (300 tests)
Chlorine UHR Reagents: HI-95771-01 (100 tests); HI-95771-03 (300 tests)
Chlorine, Free and Total HR: HI-93734-01 (100 tests); HI-93734-03 (300 tests)
Chlorine, Free ULR: HI-95762-01 (100 tests); HI-95762-03 (300 tests)
Chlorine Total: HI-93711-01 (100 tests); HI-93711-03 (300 tests); HI-93711-T (300 tests liquid)
Chlorine, Total ULR: HI-95761-01 (100 tests); HI-95761-03 (300 tests)

Free Chlorine Range   0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2)
Free Chlorine Resolution   0.01 mg/L Ultra Low Range: 0.001 mg/L
Free Chlorine Accuracy   ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading
Total Chlorine Range   0.00 to 5.00 mg/L (as Cl2) Ultra Low Range: 0.000 to 0.500 mg/L (as Cl2) Ultra High Range: 0 to 500 mg/L (as Cl2)
Total Chlorine Resolution   0.01 mg/L; 0.001 mg/L; 1 mg/L
Total Chlorine Accuracy   ±0.03 mg/L ±3% of reading Ultra Low Range: ±0.020 mg/L ±3% of reading Ultra High Range: ±3 mg/L ±3% of reading
Chlorine Method   Adaptation of the EPA 330.5 DPD method Free Chlorine (ULR) & Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th edition, 4500-Cl

 

CHROMIUM, HEXAVALENT - Reagents: HR - HI-93723-01 (100 tests); HI-93723-03 (300 tests)
LR - HI-93749-01 (100 tests); HI-93749-03 (300 tests)

Chromium, Hexavalent Range   Low Range: 0 to 300 μg/L (as Cr6+) High Range: 0 to 1000 μg/L (as Cr6+)
Chromium, Hexavalent Resolution   1 μg/L
Chromium, Hexavalent Accuracy   Low Range: ±1 μg/L ±4% of reading High Range: ±5 μg/L ±4% of reading
Chromium, Hexavalent Method   Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.

 

COLOUR, WATER

Colour, Water Range   0 to 500 PCU (Platinum Cobalt Units)
Colour, Water Resolution   1 PCU
Colour, Water Accuracy   ±10 PCU ±5% of reading
Colour, Water Method   Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.

 

COPPER - Reagents: HR - HI-93702-01 (100 tests); HI-93702-03 (300 tests)
Total copper - HI-93702T - 01 (100 tests); HI-93702T-03 (300 tests)
LR - HI-95747-01 (100 tests); HI-95747-03 (300 tests)

Copper Range   Low Range: 0.000 to 1.500 mg/L (as Cu2+) High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution   0.001 mg/L; 0.01 mg/L
Copper Accuracy   Low Range: ±0.01 mg/L ±5% of reading High Range ±0.02 mg/L ±4% of reading
Copper Method   Adaptation of the EPA bicinchoninate method

 

CYANURIC ACID - Reagents: HI-93722-01 (100 tests); HI-93722-03 (300 tests)

Cyanuric Acid Range   0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution   1 mg/L
Cyanuric Acid Accuracy   ±1 mg/L ±15% of reading
Cyanuric Acid Method   Adaptation of the turbidimetric method

 

FLUORIDE - Reagents: HR - HI-93739-01 (100 tests); HI-93739-03 (300 tests)
LR - HI-93729-01 (100 tests); HI-93729-03 (300 tests)

Fluoride Range   Low Range: 0.00 to 2.00 mg/L (as F-) High range: 0.0 to 20.0 mg/L (as F-)
Fluoride Resolution   0.01 mg/L; 0.1 mg/L
Fluoride Accuracy   Low Range: ±0.03 mg/L ±3% of reading High Range: ±0.5 mg/L ±3% of reading
Fluoride Method   Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method

 

HARDNESS, CALCIUM - Reagents: HI-93720-01 (100 tests); HI-93720-03 (300 tests)

Hardness, Calcium Range   0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution   0.01 mg/L
Hardness, Calcium Accuracy   ±0.11 mg/L ±5% of reading
Hardness, Calcium Method   Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method

 

HARDNESS, MAGNESIUM - Reagents: HI-93719-01 (100 tests); HI-93719-03 (300 tests)

Hardness, Magnesium Range   0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution   0.01 mg/L
Hardness, Magnesium Accuracy   ±0.11 mg/L ±5% of reading
Hardness, Magnesium Method   Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method

 

HARDNESS, TOTAL - Reagents: HR - HI-93735-02 (100 tests); MR - HI-93735-01 (100 tests); LR - HI-93735-00 (100 tests); HR MR &LR - HI-93735-0 (100 x 3 tests)

Hardness, Total Range   Low Range: 0 to 250 mg/L (as CaCO3) Medium Range: 200 to 500 mg/L (as CaCO3) High Range: 400 to 750 mg/L (as CaCO3)
Hardness, Total Resolution   1 mg/L
Hardness, Total Accuracy   Low Range: ±5 mg/L ±4% of reading Medium Range: ±7 mg/L ±3% of reading High Range: ±10 mg/L ±2% of reading
Hardness, Total Method   Adaptation of the EPA recommended method 130.1

 

HYDRAZINE - Reagents: HI-93704-01 (100 tests); HI-93704-03 (300 tests)

Hydrazine Range   0 to 400 μg/L (as N2H4)
Hydrazine Resolution   1 μg/L
Hydrazine Accuracy   ±4% of full scale reading
Hydrazine Method   Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method

 

IODINE - Reagents: HI-93718-01 (100 tests); HI-93718-03 (300 tests)

Iodine Range   0.0 to 12.5 mg/L (as I2)
Iodine Resolution   0.1 mg/L
Iodine Accuracy   ±0.1 mg/L ±5% of reading
Iodine Method   Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method

 

IRON - Reagents: HR - HI-93721-01 (100 tests); HI-93721-03 (300 tests)
LR - HI-93746-01 (50 tests); HI-93746-03 (150 tests)

Iron Range   Low Range: 0.000 to 1.600 mg/L (as Fe) High Range: 0.00 to 5.00 mg/L (as Fe)
Iron Resolution   0.001 mg/L; 0.01 mg/L
Iron Accuracy   Low Range: ±0.01 mg/L ±8% of reading High Range: ±0.04 mg/L ±2% of reading
Iron Method   Low Range: Adaptation of the TPTZ Method High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters

 

MAGNESIUM - Reagents: HI-937520-01 (50 tests); HI-937520-03 (150 tests)

Magnesium Range   0 to 150 mg/L (as Mg2+)
Magnesium Resolution   1 mg/L
Magnesium Accuracy   ±5 mg/L ±3% of reading
Magnesium Method   Adaptation of the Calmagite method

MANGANESE - Reagents: HR - HI-93709-01 (100 tests); HI-93709-03 (300 tests)
LR - HI-93748-01 (50 tests); HI-93748-03 (150 tests)

Manganese Range   Low Range: 0 to 300 µg/L (as Mn) High range: 0.0 to 20.0 mg/L (as Mn)
Manganese Resolution   1 µg/L; 0.1 mg/L
Manganese Accuracy   Low Range: ±0.02 mg/L ±3% of reading High Range: ±0.3 mg/L ±5% of reading
Manganese Method   Low Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method

 

MOLYBDENUM - Reagents: HI-93730-01 (100 tests); HI-93730-03 (300 tests)

Molybdenum Range   0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution   0.1 mg/L
Molybdenum Accuracy   ±0.3 mg/L ±5% of reading
Molybdenum Method   Adaptation of the mercaptoacetic acid method

 

NICKEL - Reagents: HR - HI-93726-01 (100 tests); HI-93726-03 (300 tests)
LR - HI-93740-01 (50 tests); HI-93740-03 (150 tests)

Nickel Range   Low Range: 0.000 to 1.000 mg/L (as Ni) High Range: 0.00 to 7.00 g/L (as Ni)
Nickel Resolution   0.001 mg/L; 0.01 g/L
Nickel Accuracy   Low range: ±0.010 mg/L ±7% of reading High Range: ±0.07 g/L ±4% of reading
Nickel Method   Low Range: Adaptation of the PAN method High Range: Adaptation of the photometric method

 

NITRATE - Reagents: HI-93728-01 (100 tests); HI-93728-03 (300 tests)

Nitrate Range   0.0 to 30.0 mg/L (as NO3-- N)
Nitrate Resolution   0.1 mg/L
Nitrate Accuracy   ±0.5 mg/L ±10% of reading
Nitrate Method   Adaptation of the cadmium reduction method

 

NITRITE - Reagents: HR - HI-93708-01 (100 tests); HI-93708-03 (300 tests)
LR - HI-93707-01 (100 tests); HI-93707-03 (300 tests)

Nitrite Range   Freshwater Low Range: 0 to 600 μg/L (as NO2--N) High Range: 0 to 150 mg/L (as NO2-) Seawater Ultra Low Range: 0 to 200 μg/L (as NO2--N)
Nitrite Resolution   Freshwater: 1 μg/L; 1 mg/L Seawater: 1 μg/L
Nitrite Accuracy   Freshwater Low Range: ±20 μg/L ±4% of reading High Range: ±4 mg/L ±4% of reading Seawater ±10 μg/L ±4% of reading
Nitrite Method   Adaptation of the EPA Diazotization method 354.1

 

OXYGEN, DISSOLVED - Reagents: HI-93732-01 (100 tests); HI-93732-03 (300 tests)

Oxygen, Dissolved Range   0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution   0.1 mg/L
Oxygen, Dissolved Accuracy   ±0.4 mg/L ±3% of reading
Oxygen, Dissolved Method   Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method

 

OXYGEN, SCAVENGER

Oxygen, Scavenger Range   0 to 1000 μg/L (as DEHA) 0.00 to 1.50 mg/L (as Carbohydrazide) 0.00 to 2.50 mg/L (as Hydroquinone) 0.00 to 4.50 mg/L (as ISO-ascorbic acid)
Oxygen, Scavenger Resolution   1 μg/L (DEHA); 0.01 mg/L
Oxygen, Scavenger Accuracy   ±5 μg/L ±5% of reading (DEHA)
Oxygen, Scavenger Method   Adaptation of the iron reduction method

 

OZONE - Reagents: HI-93757-01 (100 tests); HI-93757-03 (300 tests)

Ozone Range   0.00 to 2.00 mg/L (as O3)
Ozone Resolution   0.01 mg/L
Ozone Accuracy   ±0.02 mg/L ±3% of reading
Ozone Method   Colorimetric DPD Method

 

pH - Reagents: HI-93710-01 (100 tests); HI-93710-03 (300 tests)

pH Range   Photometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH
pH Resolution   Photometer: 0.1 pH pH electrode: 0.1 pH
pH Accuracy   Photometer: ±0.1 pH pH electrode: ±0.01 pH
pH Calibration   Automatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature Compensation   Automatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics)   clean electrode and check buffer/check probe displayed during calibration
pH Method   Photometer: phenol red
pH-mV Range   ±1000 mV
pH-mV Resolution   0.1 mV
pH-mV Accuracy   ±0.2 mV

 

PHOSPHATE - Reagents: HR - HI-93717-01 (100 tests); HI-93717-03 (300 tests)
LR - HI-93713-01 (100 tests); HI-93713-03 (300 tests)

Phosphate Range   Freshwater Low Range: 0.00 to 2.50 mg/L (as PO43-) High range: 0.0 to 30.0 mg/L (as PO43-) Seawater Ultra Low Range: 0 to 200 μg/L (as P)
Phosphate Resolution   Freshwater: 0.01 mg/L; 0.1 mg/L Seawater: 1 μg/L
Phosphate Accuracy   Freshwater Low Range: ±0.04 mg/L ±4% of reading High Range: ±1 mg/L ±4% of reading Seawater Ultra Low Range: ±5 μg/L ±5% of reading
Phosphate Method   Freshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method

 

POTASSIUM - Reagents: HI-93750-01 (100 tests); HI-93750-03 (300 tests)

Potassium Range   0.0 to 20.0 mg/L (as K)
Potassium Resolution   0.1 mg/L
Potassium Accuracy   ±3.0 mg/L ±7% of reading
Potassium Method   Adaptation of the Turbidimetric Tetraphenylborate method

 

SILICA - Reagents: HR - HI-96770-01 (100 tests); HI-96770-03 (300 tests)
LR - HI-93705-01 (100 tests); HI-93705-03 (300 tests)

Silica Range   Low Range: 0.00 to 2.00 mg/L (as SiO2) High Range: 0 to 200 mg/L (as SiO2)
Silica Resolution   0.01 mg/L; 1 mg/L
Silica Accuracy   Low Range: ±0.03 mg/L ±3% of reading High Range: ±1 mg/L ±5% of reading
Silica Method   Low Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO2

 

SILVER - Reagents: HI-93737-01 (50 tests); HI-93737-03 (150 tests)

Silver Range   0.000 to 1.000 mg/L (as Ag)
Silver Resolution   0.001 mg/L
Silver Accuracy   ±0.020 mg/L ±5% of reading
Silver Method   Adaptation of the PAN method

 

SULPHATE - Reagents: HI-93751-01 (100 tests); HI-93751-03 (300 tests)

Sulphate Range   0 to 150 mg/L (as SO42-)
Sulphate Resolution   1 mg/L
Sulphate Accuracy   ±5 mg/L ±3% of reading
Sulphate Method   Turbidimetric - Sulphate is precipitated with barium chloride crystals

 

ZINC - Reagents: HI-93731-01 (100 tests); HI-93731-03 (300 tests)

Zinc Range   0.00 to 3.00 mg/L (as Zn)
Zinc Resolution   0.01 mg/L
Zinc Accuracy   ±0.03 mg/L ±3% of reading

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller

  • Year Established:

    2013

  • Total Annual:

    1000000-5000000

  • Employee Number:

    30~60

  • Ecer Certification:

    Verified Supplier

Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential... Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential...

+ Read More

Get in touch with us

  • Reach Us
  • Mengchuan Instrument Co,Ltd.
  • 58 Longhe Road, Liushi Town,Wenzhou, Zhejiang, China 325604
  • https://www.differential-pressuregauge.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement