Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"50mA PLC Logic Controller Right Expansion Module Of Temperature Input","imgUrl":"https:\/\/img.chinax.com\/nimg\/d8\/db\/fbbeb2b077c9e3c3b828bc1f0012-200x200-1\/50ma_plc_logic_controller_right_expansion_module_of_temperature_input.jpg","attrs":{"Brand Name":"xinje","Model Number":"XG-E8TC-P","Certification":"CCC ISO","Place of Origin":"China"}}
Communication module, Profibus DP V1
communication module, PROFINET
communication module, DeviceNet
communication module, CANopen
communication module, EtherCAT
Phase
3 phase
Supply frequency
50...60 Hz +/- 5 %
[Us] rated supply voltage
380...480 V - 15...10 %
Nominal output current
12.7 A
Motor power kW
7.5 kW normal duty
5.5 kW heavy duty
Maximum Horse Power Rating
10 hp normal duty
7 hp heavy duty
EMC filter
Class C3 EMC filter integrated
IP degree of protection
IP20
Complementary
Discrete input number
5
Discrete input type
PTI programmable as pulse input 0…30 kHz, 24 V DC 30 V)
DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm
programmable
number of preset speeds
16 preset speeds
Discrete output number
2.0
Discrete output type
Programmable output DQ1, DQ2 30 V DC 100 mA
analogue input number
1
Analogue input type
AI1 software-configurable current 0...20 mA 250 Ohm 12 bits
AI1 software-configurable temperature probe or water level sensor
AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits
AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits
analogue output number
1
Analogue output type
Software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits
Software-configurable current AQ1 0...20 mA 500 Ohm 10 bits
Relay output R1C resistive, cos phi = 1 3 A 250 V AC
Relay output R1C resistive, cos phi = 1 3 A 30 V DC
Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Relay output R2C resistive, cos phi = 1 5 A 250 V AC
Relay output R2C resistive, cos phi = 1 5 A 30 V DC
Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC
Relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum switching current
Relay output R1B 5 mA 24 V DC
Relay output R2C 5 mA 24 V DC
Physical interface
2-wire RS 485
Connector Type
1 RJ45
Method of access
Slave Modbus RTU
Transmission Rate
4.8 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
Transmission frame
RTU
Number of addresses
1…247
Data format
8 bits, configurable odd, even or no parity
Type of polarization
No impedance
4 quadrant operation possible
True
Asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
Synchronous motor control profile
Permanent magnet motor
Reluctance motor
Pollution degree
2 IEC 61800-5-1
Maximum output frequency
0.599 kHz
Acceleration and deceleration ramps
Linear adjustable separately from 0.01...9999 s
S, U or customized
Motor slip compensation
Adjustable
Automatic whatever the load
Can be suppressed
Not available in permanent magnet motor law
Switching frequency
2...16 kHz adjustable
7...16 kHz with derating factor
Nominal switching frequency
4 kHz
Braking to standstill
By DC injection
Brake chopper integrated
True
Line current
15.3 A 380 V normal duty)
12.2 A 480 V normal duty)
20.0 A 380 V heavy duty)
16.0 A 480 V heavy duty)
Line current
20 A 380 V without line choke heavy duty)
16 A 480 V without line choke heavy duty)
15.3 A 380 V with external line choke normal duty)
12.2 A 480 V with external line choke normal duty)
11.6 A 380 V with external line choke heavy duty)
9.4 A 480 V with external line choke heavy duty)
Maximum Input Current per Phase
20.0 A
Maximum output voltage
480 V
Apparent power
12.1 kVA 480 V normal duty)
13.3 kVA 480 V heavy duty)
Maximum transient current
18.2 A 60 s normal duty)
19.1 A 60 s heavy duty)
22.3 A 2 s normal duty)
22.9 A 2 s heavy duty)
Electrical connection
Screw terminal 4...6 mm² DC bus
Screw terminal 0.2...2.5 mm² control
Screw terminal 1.5...6 mm² line side
Screw terminal 1.5...6 mm² motor
Prospective line Isc
22 kA
Base load current at high overload
12.7 A
Base load current at low overload
16.5 A
Power dissipation in W
Natural convection 134 W 380 V 4 kHz heavy duty)
Forced convection 134 W 380 V 4 kHz heavy duty)
Natural convection 164 W 380 V 4 kHz normal duty)
Forced convection 164 W 380 V 4 kHz normal duty)
Electrical connection
DC bus screw terminal 4...6 mm² AWG 12...AWG 10
Control screw terminal 0.2...2.5 mm² AWG 24...AWG 12
Line side screw terminal 1.5...6 mm² AWG 14...AWG 10
Motor screw terminal 1.5...6 mm² AWG 14...AWG 10
With safety function Safely Limited Speed (SLS)
True
With safety function Safe brake management (SBC/SBT)
True
With safety function Safe Operating Stop (SOS)
False
With safety function Safe Position (SP)
False
With safety function Safe programmable logic
False
With safety function Safe Speed Monitor (SSM)
False
With safety function Safe Stop 1 (SS1)
True
With sft fct Safe Stop 2 (SS2)
False
With safety function Safe torque off (STO)
True
With safety function Safely Limited Position (SLP)
False
With safety function Safe Direction (SDI)
False
Protection type
Thermal protection motor
Safe torque off motor
Motor phase loss motor
Thermal protection drive
Safe torque off drive
Overheating drive
Overcurrent drive
Output overcurrent between motor phase and earth drive
Output overcurrent between motor phases drive
Short-circuit between motor phase and earth drive
Short-circuit between motor phases drive
Motor phase loss drive
DC Bus overvoltage drive
Line supply overvoltage drive
Line supply undervoltage drive
Input supply loss drive
Exceeding limit speed drive
Break on the control circuit drive
Width
4.33 in (110.0 mm)
Height
10.63 in (270.0 mm)
Depth
9.21 in (234.0 mm)
Net Weight
6.39 lb(US) (2.9 kg)
Continuous output current
16.5 A 4 kHz normal duty
12.7 A 4 kHz heavy duty
Environment
Operating altitude
<= 9842.52 ft (3000 m) with current derating above 1000m
Operating position
Vertical +/- 10 degree
Product Certifications
UL
CSA
TÜV
EAC
CTick
marking
CE
Standards
IEC 61800-3
IEC 61800-5-1
IEC 60721-3
IEC 61508
IEC 13849-1
UL 618000-5-1
UL 508C
Assembly style
With heat sink
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5
Conducted radio-frequency immunity test level 3 IEC 61000-4-6
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3
Class 3S3 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)
70 m/s² at 22 ms
Maximum acceleration under vibrational stress (during operation)
5 m/s² at 9...200 Hz
Maximum deflection under vibratory load (during operation)
1.5 mm at 2...9 Hz
Permitted relative humidity (during operation)
Class 3K5 according to EN 60721-3
Volume of cooling air
20077.44 Gal/hr(US) (76.0 m3/h)
Type of cooling
Forced convection
Overvoltage category
Class III
Regulation loop
Adjustable PID regulator
noise level
46.6 dB
Pollution degree
2
Ambient air transport temperature
-40…158 °F (-40…70 °C)
Ambient air temperature for operation
5…122 °F (-15…50 °C) without derating vertical position)
122…140 °F (50…60 °C) with derating factor vertical position)
Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential... Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential...