Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"Case Isolated Accelerometer Acceleration Transducer GE 330400-01-05 Bently","imgUrl":"https:\/\/img.chinax.com\/nimg\/83\/05\/90cad5f2bca28ae8708f3525795e-200x200-1\/case_isolated_accelerometer_acceleration_transducer_ge_330400_01_05_bently_nevada_330400_2f330425.jpg","attrs":{"Brand Name":"Bently Nevada","Model Number":"GE 330400-01-05","Certification":"CE","Place of Origin":"USA"}}
{"title":"EPCOS B43584-s6228-m4 Aluminum Electrolytic Capacitor 500v 2200uf With Screw","imgUrl":"https:\/\/img.chinax.com\/nimg\/c7\/7d\/8c3616aa806ff2327407735f1fed-200x200-1\/epcos_b43584_s6228_m4_aluminum_electrolytic_capacitor_500v_2200uf_with_screw_termination.jpg","attrs":{"Brand Name":"EPCOS","Model Number":"B43584-s6228-m4","Certification":"CE","Place of Origin":"china"}}
{"title":"Endress Hauser Deltapilot M Mfb50 Hydrostatic Level Measurement Fmb50-2ed1\/0","imgUrl":"https:\/\/img.chinax.com\/nimg\/cd\/1a\/c284d1448022be755904b4f1c303-200x200-1\/endress_hauser_deltapilot_m_mfb50_hydrostatic_level_measurement_fmb50_2ed1_2f0.jpg","attrs":{"Brand Name":"Endress Hauser","Model Number":"Fmb50-2ed1\/0","Place of Origin":"China","Minimum Order Quantity":"1"}}
{"title":"248RANAQ4 Rosemount Din Rail Transmitter 248R IP65 Temperature Transmitter","imgUrl":"https:\/\/img.chinax.com\/nimg\/04\/cb\/b9e00ec6a3c408c23732c5151cef-200x200-1\/248ranaq4_rosemount_din_rail_transmitter_248r_ip65_temperature_transmitter_sensor.jpg","attrs":{"Brand Name":"Rosemount","Model Number":"248RANAQ4","Certification":"CCC.CE","Place of Origin":"America"}}
{"title":"Endress Hauser Level Sensor E+H Hydrostatic Level Measurement Deltapilot Fmb50","imgUrl":"https:\/\/img.chinax.com\/nimg\/ba\/91\/c2e2954df2eb3c6442f8c41ef50c-200x200-1\/endress_hauser_level_sensor_e_2bh_hydrostatic_level_measurement_deltapilot_fmb50_2ed1_2f0.jpg","attrs":{"Brand Name":"Endress Hauser","Model Number":"FMB50-2ED1\/0","Place of Origin":"China","Minimum Order Quantity":"1"}}
{"title":"MC Digital Temperature Controller 220v 250V 10A Black 96*96mm","imgUrl":"https:\/\/img.chinax.com\/nimg\/99\/a4\/c31c00f3c6cb3e0fbe1eb5869256-200x200-1\/mc_digital_temperature_controller_220v_250v_10a_black_96_2a96mm.jpg","attrs":{"Brand Name":"MC","Model Number":"REX-C100-C400-C700-C900","Certification":"CCC CE","Place of Origin":"China"}}
Continuous level measurement behind non-metallic and non-conductive surfaces
Media
dry bulk material; aqueous solutions; oils
Cannot be used for
very adhesive media
Electrical data
Operating voltage [V]
10...30 DC; (IO-Link: 18...30 DC)
Current consumption [mA]
< 50
Protection class
III
Reverse polarity protection
yes
Max. power-on delay time [ms]
1300
Measuring principle
capacitive
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 3
Outputs
Electrical design
PNP/NPN; (configurable)
Number of digital outputs
3
Permanent current rating of switching output DC [mA]
200
Max. resistance switching output [Ω]
8
Short-circuit protection
yes
Type of short-circuit protection
yes (non-latching)
Overload protection
yes
Monitoring range
Measuring range [mm]
< 200
Measuring/setting range
Detection range [mm]
228
Set point SP [%]
5...95
Reset point rP [%]
4...94
In steps of [%]
1
Accuracy / deviations
Repeatability [% of the final value]
2
Offset deviation [% of the final value]
4
Resolution [% of the final value]
1
Linearity deviation [% of the final value]
1
Reaction times
Response time [ms]
1300
Software / programming
Parameter setting options
Damping; hysteresis / window; fault indication; Diagnostic function; Sensitivity; internal temperature; limitation of measuring range; adjustable switching delay; zero-point calibration; direction of installation; LEDs can be deactivated
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Digital Measuring Sensor Profile, Common Profile
SIO mode
yes
Required master port class
A
Process data analog
1
Process data binary
3
Min. process cycle time [ms]
9.6
IO-Link process data (cyclical)
Function
bit length
process value
16
exponent
8
device status
4
binary switching information
3
IO-Link functions (acyclical)
direction of installation; limitation of sensor elements; Sensitivity; minimum recognition threshold; Performance in case of a fault; error delay; Damping; LED mode; switch-on cycle counter; operating hours counter; switching cycles counter; min./max. process value; internal temperature; min./max. internal temperature; diagnostic data level
Supported DeviceIDs
Type of operation
DeviceID
default
924
Note
For further information please see the IODD PDF file at "Downloads"
Operating conditions
Applications
DIN EN 60654-1 application class B2
Ambient temperature [°C]
-20...80
Storage temperature [°C]
-25...85
Protection
IP 65
Tests / approvals
EMC
DIN EN 61000-6-4 30 - 230 MHz
40 dBµV/m QP / 10 m distance
230 - 1 GHz
47 dBµV/m QP / 10 m distance
DIN EN 61000-4-2
± 25 kV AD / ± 25 kV CD
DIN EN 61000-4-3
80 MHz - / 1 GHz 10 V/m
DIN EN 61000-4-4
± 2.5 kV / 5 kHz
± 2.5 kV / 100 kHz
DIN EN 61000-4-6
10 V
Shock resistance
EN 60068-2-27
15 g 11 ms
Vibration resistance
EN 60068-2-6
5 g (10...2000 Hz)
MTTF [years]
290.43
UL approval
Ta
-25...60 °C
Enclosure type
Type 1
voltage supply
Limited Voltage/Current
UL approval number
D006
File number UL
E174191
Mechanical data
Weight [g]
377.5
Dimensions [mm]
250 x 28 x 16.7
Material
PBT; PC;
Displays / operating elements
Display
Power
1 x LED, green
Switching status
3 x LED, yellow
Function
20 x LED, green
Accessories
Items supplied
adhesive tape: 1 x 23 mm x 240 mm
Accessories (optional)
Mounting adapter: 2, E12675
Mounting adapter: 2, E12676
Fixing strap: 5, E10880
adhesive tape: 10, E12677
Remarks
Remarks
When used on IO-Link class B masters, switching outputs OUT2, OUT3 must be turned off
Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential... Mengchuan Instrument Co., Ltd. is located in Liushi Town, Yueqing City, Wenzhou, Zhejiang Province, surrounded by the beautiful world natural and cultural heritage - Yandang Mountain! It is mainly engaged in 2000 differential pressure gauge, red oil differential pressure gauge, pressure differential...