| Payment Terms | T/T, Western Union |
| Supply Ability | 300pcs / week |
| Delivery Time | 2-3 work days |
| Packaging Details | 1pcs / box |
| color | white |
| material | plastic and metal |
| orignal code | 6850645 |
| package | box |
| weight | 25g |
| Electrical Connector | old plated slip rings |
| Brand Name | drager |
| Model Number | 6850645 |
| Certification | CE |
| Place of Origin | Germany |
View Detail Information
Explore similar products
Drager Cable Harness Spirolog Sensor For Savina Savina300 8414028 1 Year
Medical Oxygen Sensor O2 Cells Durable C1 C2 For Respiratory Equipment
Vela Analytical Oxygen Sensor Cell Industries Inc All PSR-11-75-KE4 CE Approval
Analytical Industries Medical Oxygen Sensor Inc / AII PSR-11-75-KE8 For SLE-5000
Product Specification
| Payment Terms | T/T, Western Union | Supply Ability | 300pcs / week |
| Delivery Time | 2-3 work days | Packaging Details | 1pcs / box |
| color | white | material | plastic and metal |
| orignal code | 6850645 | package | box |
| weight | 25g | Electrical Connector | old plated slip rings |
| Brand Name | drager | Model Number | 6850645 |
| Certification | CE | Place of Origin | Germany |
| High Light | envitec oxygen sensor ,drager oxygen sensor ,6850645 O2 Sensor Cell | ||
Drager 6850645 medical oxygen sensor o2 cell / oxygen battery
Technical Specifications
| Measuring range | 0-100% | |||
| Accuracy | +/-2% of full scale | |||
| Signal output | 10-14mV | |||
| Linearity | +/-2% of full scale | |||
| Response T90 | 13 sec | |||
| Temp Coefficient | compensated | |||
| Shelf Life | 6 months | |||
| Humidity Non-condensing | 0-99% RH | |||
| Operating Temp | 0 to 40℃ | |||
| Recommended storage | 0 to 25℃ | |||
| Expected Life | 60 months | |||
| Warrangty | 18 months | |||
| Electrical Connector | gold plated slip rings | |||
| Measurement Range: | 0-100 % oxygen |
| Accuracy and Repeatability: | < 1 % vol. O2when calibrated at 100 % O2 |
| Zero Ofset: | < 0.5 % vol. O2in 100% N2, applied 5 minutes |
| Linearity Error: | < 3 % relative |
| Cross Interference: | < 0.5 % vol. O2response to: |
| 10 % CO2balance N2 | |
| 80% N2O balance N2 | |
| 7.5% Halothane balance N2 | |
| 7.5 % Isofurane balance N2 | |
| 7.5 % Enfurane balance N2 | |
| 9% Sevofurane balance N2 | |
| 20% Desfurane balance N2 | |
| Infuence of Humidity: | - 0.03 % rel. per % RH at 25C |
| Infuence of Pressure: | proportional to change in oxygen partial |
| pressure | |
| Infuence of Mechanical Shock: | < 1% relative after a fall from 1m |
| Operating Temperature: | 0 to 50C |
| Temperature Compensation: | built-in NTC compensation (see below) |
| Efect of Temperature | between +5 C and +25 C: 3 % relative error |
| Compensation (steady state): | between 0 C and +50 C: 8 % relative error |
| Operating Humidity: | 0-99 % RH non-condensing |
| Long Term Output Drift: | < 1 % vol oxygen per month |
| typically < - 15 % relative over lifetime | |
| Storage Temperature: | -20 to +50 C |
| Recommended Storage: | +5 to +15 C |
| Recommended Load: | 10 kOhms |
| Warm-Up Time: | < 30 minutes, after replacement of sensor |
| Weight: | approximately 28 grams |
| approximately 43 grams E61912 series |
![]()
![]()
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Agent,Exporter,Seller
Year Established:
2010
Total Annual:
1000000-5000000
Ecer Certification:
Verified Supplier
Shenzhen pray-med technology co.,ltd,is a collection of research, development, production and sales medical wire connector in the integration of high-tech enterprises, is a medical electronic instrument parts and material suppliers, products include disposable probe pulse blood oxygen saturation, re... Shenzhen pray-med technology co.,ltd,is a collection of research, development, production and sales medical wire connector in the integration of high-tech enterprises, is a medical electronic instrument parts and material suppliers, products include disposable probe pulse blood oxygen saturation, re...
Get in touch with us
Leave a Message, we will call you back quickly!