China Industrial Servo Inverter VFD 0-400Hz Adjustable Speed Full Protection For Pumps
China Industrial Servo Inverter VFD 0-400Hz Adjustable Speed Full Protection For Pumps

  1. China Industrial Servo Inverter VFD 0-400Hz Adjustable Speed Full Protection For Pumps
  2. China Industrial Servo Inverter VFD 0-400Hz Adjustable Speed Full Protection For Pumps
  3. China Industrial Servo Inverter VFD 0-400Hz Adjustable Speed Full Protection For Pumps

Industrial Servo Inverter VFD 0-400Hz Adjustable Speed Full Protection For Pumps

  1. MOQ:
  2. Price:
  3. Get Latest Price
Payment Terms ,MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability 500-10000 per Month
Delivery Time 5 Days
Packaging Details Carton and plywood box packaging
Control Mode SVC/VF/FVC
Power Phase Number Single/ Three Phase
Power 5.5-800KW
Brand Name ZFENG
Model Number ZF900 Series
Certification CE、CB、CCC、ISO9001、ISO14001、ISO45001、EN61439、EN61000

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms ,MoneyGram,Western Union,T/T,D/P,D/A,L/C Supply Ability 500-10000 per Month
Delivery Time 5 Days Packaging Details Carton and plywood box packaging
Control Mode SVC/VF/FVC Power Phase Number Single/ Three Phase
Power 5.5-800KW Brand Name ZFENG
Model Number ZF900 Series Certification CE、CB、CCC、ISO9001、ISO14001、ISO45001、EN61439、EN61000
High Light 400Hz Industrial Servo VFDAdjustable Speed Industrial Servo VFDPumps Industrial Servo VFD

Industrial Servo Inverter VFD: 0-400Hz Adjustable Speed, Full Protection For Pumps & Fans


1. Core Features

  • Wide Speed Range (0-400Hz)
    • Enables precise speed control for low-speed (e.g., gentle fan rotation) and high-speed (e.g., centrifugal pump acceleration) applications.
    • Supports soft start/stop to reduce mechanical stress and energy consumption.
  • Full Motor Protection Suite
    • Overload Protection: Automatically trips if current exceeds rated capacity (e.g., 150% overload for 1 minute).
    • Overvoltage/Undervoltage Protection: Safeguards against voltage surges (e.g., lightning strikes) or drops (e.g., grid instability).
    • Overheating Protection: Monitors IGBT temperature and shuts down if thermal limits are exceeded.
    • Phase Loss Protection: Detects missing phases (e.g., L1, L2, L3) and prevents motor burnout.
    • Ground Fault Protection: Isolates the system during insulation failures to prevent electric shocks.
  • Optimized for Pumps & Fans
    • PID Control: Adjusts motor speed in real-time to maintain constant pressure (pumps) or airflow (fans), reducing energy waste by up to 30%.
    • Sleep/Wake Function: Automatically powers down pumps/fans during idle periods (e.g., nighttime) and restarts when demand resumes.
    • Dry Run Protection: For pumps, detects low liquid levels and stops the motor to prevent damage.

2. Technical Specifications

Parameter Details
Input Voltage Single-phase 220V or three-phase 380V ±15% (50/60Hz)
Output Frequency 0–400Hz (adjustable via keypad/remote control)
Control Modes V/F, Sensorless Vector Control (SVC), Torque Control
Enclosure Rating IP20 (indoor) or IP55 (outdoor/dusty environments)
Communication RS485 (Modbus RTU), optional Profibus-DP/EtherCAT
Display LED/LCD screen showing frequency, current, fault codes, and operating status


3. Key Applications

  • Centrifugal Pumps
    • Challenge: Throttling valves waste energy when reducing flow.
    • Solution: VFD adjusts pump speed to match demand, cutting power use by 40% (e.g., HVAC cooling towers).
  • Axial Flow Fans
    • Challenge: Fixed-speed fans cause noisy operation and excessive airflow.
    • Solution: VFD ramps down fan speed during low-demand periods (e.g., nighttime ventilation), reducing noise by 10dB.
  • Water Treatment Systems
    • Challenge: Manual control leads to inconsistent chemical dosing.
    • Solution: VFD integrates with flow meters and PID loops to maintain precise dosing rates (e.g., chlorine injection pumps).

4. FAQs

  • Q: Can this VFD handle single-phase motors?
    A: No, it requires three-phase motors. For single-phase applications, use a phase converter or a dedicated single-phase VFD.

  • Q: How often should I perform maintenance?
    A: Check cooling fans and heat sinks every 6 months. Replace capacitors every 5–7 years.

  • Q: Is IP55 necessary for indoor use?
    A: Not required, but IP55 models resist dust and accidental water splashes, extending lifespan in workshops.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter,Seller

  • Year Established:

    2004

  • Total Annual:

    10000000-15000000

  • Employee Number:

    60~100

  • Ecer Certification:

    Verified Supplier

GuangDong Zhufeng Electric Co.,LTD established in 2004, is a national high-tech and energy save enterprise with approval by National Development and Reform Commission. Focusing on the development and production and sale of products of “energy saving and control speed and variable speed” ... GuangDong Zhufeng Electric Co.,LTD established in 2004, is a national high-tech and energy save enterprise with approval by National Development and Reform Commission. Focusing on the development and production and sale of products of “energy saving and control speed and variable speed” ...

+ Read More

Get in touch with us

  • Reach Us
  • Guangdong Zhufeng Electric Co., Ltd.
  • NO.2,JINGHU AVENUE, HUADU DISTRICT, GUANGZHOU CITY, GUANGDONG PROVINCE
  • https://www.drivesvfd.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement