China 630A Mechanism Vacuum Circuit Breaker For Arc Interruption
China 630A Mechanism Vacuum Circuit Breaker For Arc Interruption

  1. China 630A Mechanism Vacuum Circuit Breaker For Arc Interruption
  2. China 630A Mechanism Vacuum Circuit Breaker For Arc Interruption
  3. China 630A Mechanism Vacuum Circuit Breaker For Arc Interruption

630A Mechanism Vacuum Circuit Breaker For Arc Interruption

  1. MOQ: >=1 Pieces
  2. Price: Negotiation
  3. Get Latest Price
Supply Ability 100 Piece/Pieces per Month
Packaging Details EXPORTING PACKING
Standard IEC
Rated Current 630A,1250A, 1600A
Rated Voltage 12KV
Mechanical life 10000
Usage RING UNIT CARBINET
Port NINGBO
Brand Name XK
Model Number ZN63-12/630A
Certification ISO9001 / GB / IEC
Place of Origin Zhejiang, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Supply Ability 100 Piece/Pieces per Month Packaging Details EXPORTING PACKING
Standard IEC Rated Current 630A,1250A, 1600A
Rated Voltage 12KV Mechanical life 10000
Usage RING UNIT CARBINET Port NINGBO
Brand Name XK Model Number ZN63-12/630A
Certification ISO9001 / GB / IEC Place of Origin Zhejiang, China
High Light 630A Vacuum Circuit BreakerMechanism Vacuum Circuit BreakerArc Interruption Vacuum Circuit Breaker

Hot sale 12KV 50HZ permanent magnetic mechanism three-phase vacuum circuit breaker

Item Unit Data
Rated voltage KV 12
Rated frequency HZ 50
Rated insulation level 1min Power frequency withstand voltage KV 42(fracture 48)
Peak Lightning lmpulse Withstand voltage KV 75(fracture 84)
Rated Breaking Current KA 20 25 31.5 40
Rated Current A 630 630 1250 1600 1250 1600
1250 1250 2000 2500 2000 2500
Rated short time withstand current KA
20
25
31.5
40
Rated peak withstand current KA
50
63
80
100
Rated short circuit breaking current KA
50
63
80
100
Rated continous time under short circuit current S 4
Secondary power frequncy withstand voltage V 2000V

 

Product Description

 

Vacuum Arc Stability:

In a 50 Hz ac circuit the current passes through zero value 100 times in a second (i.e., once every 10 ms). It is desirable that the current is interrupted when it is passing through zero value, otherwise overvoltage will be induced due to current chopping. Therefore, for successful arc interruption it is necessary that the arc be stable for half-cycle duration and particularly that it continues to exist at currents approaching zero.

The arc stability is found to depend upon:

(i) The contact material and its vapour pressure and

(ii) Circuit parameters such as voltage, current, capacitance and inductance.

In low current circuits most of the evaporation takes place at discrete points, called the cathode spots, while at higher currents the evaporation takes place from cathode and anode spots. In addition to these sources gas is added to the enclosure of the contacts when it is stripped from other parts of the enclosure because of high temperature and impinging metal vapour.

Vapour pressure and arc stability are found to be interrelated. The higher the vapour pressure at lower temperature, the better is the stability of the arc i.e., the longer the life time of the arc. There are certain metals like Zn, Bi, which provide such characteristics and are better electrode materials for vacuum circuit breakers. Besides the vapour pressure, the thermal conductivity of the metal also affects the current chopping level.

A good heat conducting metal will cool very rapidly and its contact surface temperature will fall. This will reduce the evaporation rate and the arc will be chopped because of insufficient vapour. On the other hand, a bad heat conductor will maintain its temperature and vaporization for a longer time and the arc will be more stable.


Shunting the contacts with different values of capacitance reduces the average life time of the arc. The higher the value of the capacitance, the lower is the average life time of the arc. An inductance in series, on the other hand increases the lifetime of the arc. Similarly, higher the system operating voltage, longer is the duration of the arc. This is because more restoring voltage is available to keep the arc alive. 

Related Products
 
Company Information

   

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2011

  • Total Annual:

    5M-10M

  • Employee Number:

    >100

  • Ecer Certification:

    Active Member

Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise specializing in developping, design, manufacture, sales, import and export of low voltage and high voltage electrical products.  Company main products: indoor and outdoor high voltage vacuum circuit breaker, load break switch... Zhejiang Xinkou Power Equipment Co.,Ltd, is a high-tech enterprise specializing in developping, design, manufacture, sales, import and export of low voltage and high voltage electrical products.  Company main products: indoor and outdoor high voltage vacuum circuit breaker, load break switch...

+ Read More

Get in touch with us

  • Reach Us
  • ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD
  • No.318 Shengli Road, Xixi Village, Huheng Industrial Zone, Yueqing City, Zhejiang Province.
  • https://www.dropout-fuse.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement