| Payment Terms | T/T,Western Union |
| Supply Ability | 1000pcs/month |
| Delivery Time | 5-8 work days |
| Packaging Details | cartons + PE |
| Protectionclass | IP68 |
| Product Name | Electric Coolant Pump |
| Powersupply | DC 24V |
| Flowrate | 40 L/min @ Head is 17m |
| Pumpmaterial | Aluminum Alloy |
| Operatingtemperaturerange | -40°C to 85°C |
| Pumptype | Centrifugal |
| Productname | 5G Base Station Coolant Pumps |
| Operatingpressure | -0.02-0.3 MPa |
| Application | Cooling 5G base station equipment |
| Motorpower | 240W |
| Coolingmethod | Liquid Cooling |
| Noiselevel | ≤60 dB |
| Brand Name | Bextreme Shell |
| Model Number | OWP-BL43-426C |
| Certification | CE |
| Place of Origin | China |
View Detail Information
Explore similar products
High Flow 6000L/h 24V DC Electric Coolant Pump for Energy Storage Cooling with
24V 6 Bar High Lift Electric Coolant Pump for DC Fast Charging Gun Cooling with
DC 24V Brushless Water Pump for Cooling Purposes of Energy Storage Project With
24 VDC BLDC Water Pump with Long Service Life and Excellent Efficiency for
Product Specification
| Payment Terms | T/T,Western Union | Supply Ability | 1000pcs/month |
| Delivery Time | 5-8 work days | Packaging Details | cartons + PE |
| Protectionclass | IP68 | Product Name | Electric Coolant Pump |
| Powersupply | DC 24V | Flowrate | 40 L/min @ Head is 17m |
| Pumpmaterial | Aluminum Alloy | Operatingtemperaturerange | -40°C to 85°C |
| Pumptype | Centrifugal | Productname | 5G Base Station Coolant Pumps |
| Operatingpressure | -0.02-0.3 MPa | Application | Cooling 5G base station equipment |
| Motorpower | 240W | Coolingmethod | Liquid Cooling |
| Noiselevel | ≤60 dB | Brand Name | Bextreme Shell |
| Model Number | OWP-BL43-426C | Certification | CE |
| Place of Origin | China | ||
| High Light | 24V Electric Coolant Pumps ,240W Electric Coolant Pumps ,Centrifugal coolant electric pump | ||
Electric Coolant Pump OWP-BL43-426C: Ideal for 5G Base Transceiver Station Cooling
The OWP-BL43-426C Electric Coolant Pump is a high-performance, reliable solution designed to meet the demanding cooling needs of various industrial applications, with a primary focus on 5G Base Transceiver Stations (BTS). This pump combines advanced technology, robust construction, and versatile features to ensure efficient and stable operation in harsh environments.
Specification Parameters Table
| Parameter | Details |
|---|---|
| Power Input | 24VDC (18-32VDC) |
| Rated Power | 240W |
| Rated Flow Rate | 2400L/H @ H=17M |
| Max Flow | 5000L/H |
| Max Lift Head | 20M |
| Medium | Glycol (50-60%) + water, dielectric oil, mineral oil, electronic fluorinated solution, etc. |
| Connection Type | Flange Quick-Connect |
| Speed Regulation | PWM |
| Fault Feedback Signal | Available |
| IP Grade | IP68 |
| Noise Control | ≤60dB |
| Service Life | >20000hours |
| Weight | 2200g |
| Working Ambient Temperature | -40℃ to +85℃ (-40°F to +185°F) |
| Humidity | ≤90% |
| Connector Model | AMP282106-1 (Matched plug AMP282088-1) |
| Nozzle Size | 50.5mm (Flange) |
Application: 5G Base Transceiver Station Liquid Cooling
5G Base Transceiver Stations generate significant heat due to their high-power components and continuous operation, making effective cooling critical for maintaining performance and extending equipment lifespan. The OWP-BL43-426C Electric Coolant Pump plays a vital role in 5G BTS liquid cooling systems. Its ability to handle various coolants, including glycol-water mixtures and dielectric oils, makes it compatible with the most common cooling solutions used in 5G infrastructure.
With a rated flow rate of 2400L/H (up to 5000L/H max) and a max lift head of 20M, the pump ensures efficient circulation of coolant throughout the cooling loop, rapidly transferring heat away from sensitive 5G components like transceivers and power amplifiers. The wide working ambient temperature range (-40℃ to +85℃) and IP68 protection rating allow it to operate reliably in outdoor or indoor 5G BTS environments, regardless of extreme temperatures or moisture. Additionally, the pump’s low noise level (≤60dB) minimizes disruption in urban or residential areas where 5G stations are often located.
Key Advantages
PWM Regulation & Fault Feedback
![]()
Flow VS Head
![]()
Dimensions
![]()
![]()
Company Details
Business Type:
Manufacturer
Year Established:
2016
Total Annual:
12,000,000-15,000,000
Employee Number:
150~220
Ecer Certification:
Verified Supplier
.gtr-container-a1b2c3 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; } .gtr-container-a1b2c3 p { font-size: 14px; margin-bottom: 16px; tex... .gtr-container-a1b2c3 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; } .gtr-container-a1b2c3 p { font-size: 14px; margin-bottom: 16px; tex...
Get in touch with us
Leave a Message, we will call you back quickly!