| Performance | Q=275L/min @H=30m |
| Supply Ability | 10000pcs/month |
| Working voltage | DC 48V |
| Protection grade | IP 67 |
| Payment Terms | T/T,Western Union |
| Application | Coolant circulation system |
| Product name | PMSM brushless coolant pump |
| Material | Cast aluminum |
| Service life | More than 40000h |
| Type | Shield pump |
| System pressure rating | -0.9-10 Bar |
| Model no. | OWP-BL1500H-D3-1 |
| Model Number | OWP-BL2000H-D3-1 |
| Place of Origin | China |
| Brand Name | Bextreme Shell |
View Detail Information
Explore similar products
Product Specification
| Performance | Q=275L/min @H=30m | Supply Ability | 10000pcs/month |
| Working voltage | DC 48V | Protection grade | IP 67 |
| Payment Terms | T/T,Western Union | Application | Coolant circulation system |
| Product name | PMSM brushless coolant pump | Material | Cast aluminum |
| Service life | More than 40000h | Type | Shield pump |
| System pressure rating | -0.9-10 Bar | Model no. | OWP-BL1500H-D3-1 |
| Model Number | OWP-BL2000H-D3-1 | Place of Origin | China |
| Brand Name | Bextreme Shell | ||
| High Light | DC48V shielded centrifugal pump ,BLDC water pump for cooling systems ,centrifugal pump with liquid-to-air cooling | ||
The OWP-BL2000H-D3-1 is a horizontal single-stage centrifugal shielded electronic pump designed for Liquid-to-Air cooling systems and CDU applications.
It delivers 275 L/min flow rate at 30m head with DC48V power supply, featuring IP67 protection and cast aluminum wetted parts.
This pump integrates brushless permanent magnet synchronous motor technology, ensuring high efficiency and a service life of over 40,000 hours.
It supports deionized water and antifreeze media, with multiple protection functions for reliable operation in harsh environments.
Liquid-to-Air cooling systems and CDUs face critical challenges in high-power heat dissipation scenarios.
Leakage risks from traditional pumps threaten system safety, especially when handling expensive or sensitive cooling media.
Inefficient motors lead to high energy consumption and shortened service life, increasing operational costs.
Extreme temperature fluctuations (-40℃~60℃) and humidity (5~95%) demand robust environmental adaptability.
Lack of comprehensive protection functions often results in pump damage from dry running, overvoltage, or reverse connection.
The centrifugal shielded design eliminates leakage risks by integrating rotor and impeller in a sealed chamber.
Brushless permanent magnet synchronous motor achieves higher efficiency than conventional motors, reducing energy loss.
Constant flow control maintains stable cooling performance regardless of system pressure changes.
Multiple protection mechanisms prevent pump failure: reverse connection, dry running, overvoltage, overcurrent, overload and overtemperature protection.
Cast aluminum wetted parts offer excellent corrosion resistance and structural stability.
IP67 protection rating ensures reliable operation in dusty, humid, or water-exposed environments.
| Parameter | Details |
|---|---|
| Model | OWP-BL2000H-D3-1 |
| Product Type | Horizontal Single-Stage Centrifugal Shielded Electronic Pump |
| Rated Voltage | DC48V |
| Operating Voltage Range | DC42~58V |
| Protection Level | IP67 |
| Weight | 4.5Kg |
| Rated Power | 2500W |
| Flow & Head | 275 L/min @ 30m Head |
| Service Life | ≥40000h |
| Noise Level | ≤70dB (measured 1 meter away from pump) |
| System Pressure | -0.9Bar~10Bar |
| Maximum Applicable Altitude | ≤3000m |
| Operating Ambient Humidity | 5~95% |
| Ambient Temperature | -40℃~60℃ |
| Medium Temperature | -30℃~60℃ |
| Communication Method | RS485 |
| Wetted Component Material | Cast Aluminum |
| Inlet & Outlet | φ38mm inner flow diameter, φ64mm quick-install clamp chuck |
Adopt the standard ratio: 1.5 L/min flow corresponds to 1 KW heat dissipation capacity.
With the maximum available flow of 275 L/min, the pump can support hosts with heat load up to around 183 KW.
Select OWP-BL2000H-D3-1 for Liquid-to-Air systems or CDUs whose total heat dissipation ≤ 183 KW.
Check that the on-site power supply stays within DC42V ~ 58V working voltage range.
Avoid excessive voltage fluctuation which may trigger built-in electrical protection.
This pump is designed for deionized water and antifreeze only.
Confirm the coolant temperature stays within -30℃ ~ 60℃ during long-term operation.
Verify ambient temperature, humidity, altitude and system pressure match product specifications.
Do not use the pump beyond defined environmental boundaries to avoid shortened service life.
Match pipeline layout with φ64mm quick-install chuck interface.
Reserve sufficient installation space for the 4.5kg horizontal mounted pump.
Q: What is the production lead time of OWP-BL2000H-D3-1?
A: The standard lead time is 20 working days after formal order confirmation.
Q: Can this electronic coolant circulation pump accept customized modifications?
A: Yes, customized solutions are available according to your actual system requirements.
Q: What about warranty, service life and technical support?
A: The pump enjoys a 2-year warranty with a service life ≥40000 hours; our team offers fast-response technical support.
Company Details
Business Type:
Manufacturer
Year Established:
2016
Total Annual:
12,000,000-15,000,000
Employee Number:
150~220
Ecer Certification:
Verified Supplier
.gtr-container-a1b2c3 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; } .gtr-container-a1b2c3 p { font-size: 14px; margin-bottom: 16px; tex... .gtr-container-a1b2c3 { font-family: Verdana, Helvetica, "Times New Roman", Arial, sans-serif; color: #333; line-height: 1.6; padding: 16px; max-width: 100%; box-sizing: border-box; } .gtr-container-a1b2c3 p { font-size: 14px; margin-bottom: 16px; tex...
Get in touch with us
Leave a Message, we will call you back quickly!