| Delivery Time | 20 work days |
| Packaging Details | Cartons |
| Payment Terms | T/T |
| Supply Ability | 1000pcs/month |
| Operate Voltage | AC 380V |
| Model Number | OWP-BL3000H-A3-1 |
| Certification | CE |
| Brand Name | Bextreme Shell |
| Place of Origin | China |
View Detail Information
Explore similar products
24VDC BLDC Coolant Pump for Liquid-cooled System in Laser Cutting Equipment
Electric Coolant Pump OWP-BL43-426C: Ideal for Reflow Oven Liquid Cooling
High Performance 24V BLDC Coolant Pump for Electric Insulating Oil Circulation
Manufacturer 24V Electric Coolant Pump for Glycol Circulation
Product Specification
| Delivery Time | 20 work days | Packaging Details | Cartons |
| Payment Terms | T/T | Supply Ability | 1000pcs/month |
| Operate Voltage | AC 380V | Model Number | OWP-BL3000H-A3-1 |
| Certification | CE | Brand Name | Bextreme Shell |
| Place of Origin | China | ||
| High Light | centrifugal PMSM electronic coolant pump ,electric water pump for CDU ,coolant distribute unit water pump | ||
| Parameter Category | Specific Parameters | Value |
|---|---|---|
| Electrical Parameters | Rated Voltage | AC380V |
| Operating Voltage | AC380V | |
| Rated Power | 3000W | |
| Mechanical Parameters | Weight | 8Kg |
| Protection Level | IP67 | |
| System Pressure Range | -0.9Bar ~ 10Bar | |
| Inlet/Outlet Design | φ64mm Quick-Install Chuck | |
| Wetted Component Material | Cast Aluminum | |
| Environmental Parameters | Applicable Altitude | ≤5000m |
| Operating Environment Humidity | 5~95% | |
| Environment Temperature Range | -40℃ ~ 85℃ | |
| Media Parameters | Compatible Media | Deionized Water, Antifreeze |
| Medium Temperature Range | -40℃ ~ 85℃ | |
| Performance Parameters | Flow Rate at 25m Head | 400L/min |
| Service Life | ≥20000h | |
| Noise Level (1m Distance) | ≤70dB | |
| Communication Parameters | Communication Protocol | RS485 |
This product is exclusively tailored for Coolant Distribute Units (CDU), serving as the key power unit for coolant circulation in liquid cooling systems. The technical parameters of the OWP-BL3000H-A3-1 are precisely matched to the operational demands of CDU:
The compatibility with deionized water and antifreeze aligns with the common coolant types used in CDU systems, ensuring chemical stability and avoiding component corrosion. The wide temperature range (-40℃~85℃) enables reliable operation in both low-temperature outdoor installations and high-temperature industrial environments where CDU systems are typically deployed.
With a system pressure range of -0.9Bar to 10Bar, the pump adapts to the pressure fluctuations commonly encountered in CDU circulation loops, maintaining consistent flow output. The IP67 protection rating prevents dust and water ingress, a critical requirement for CDU units operating in harsh industrial settings.
The φ64mm quick-install chuck design facilitates rapid assembly and disassembly during CDU system installation or maintenance, improving operational efficiency. Additionally, the RS485 communication interface allows for real-time monitoring and control of the pump’s operating status, integrating seamlessly with CDU system management platforms.
CDU systems require coolant circulation solutions that prioritize heat dissipation efficiency, system adaptability, and long-term stability to ensure continuous operation of the associated cooling infrastructure. High heat load handling is a core demand, as CDU units are tasked with dissipating significant heat from industrial equipment or data center servers.
This necessitates a pump with sufficient flow rate and head to deliver coolant promptly across the circulation loop. Adaptability to diverse operating conditions is another key requirement, as CDU systems may be deployed in varying altitudes, humidity levels, and temperature extremes.
Stability and reliability are non-negotiable, as pump failures can lead to CDU system downtime and subsequent equipment overheating. Leak-proof performance is critical to protect sensitive components within the CDU and surrounding infrastructure.
Energy efficiency is also a growing industry focus, driving the demand for low-power-consumption pumps that reduce overall system operating costs. The OWP-BL3000H-A3-1 addresses these demands through its technical parameter configuration and structural design, aligning with the core needs of CDU applications.
The OWP-BL3000H-A3-1 operates based on the principle of centrifugal force generated by impeller rotation. When powered by the AC380V supply, the permanent magnet brushless synchronous motor drives the closed twisted impeller to rotate at high speed.
This rotation creates a pressure difference between the pump’s inlet and outlet: the low pressure at the inlet draws coolant (deionized water or antifreeze) into the pump chamber, while the centrifugal force generated by the impeller propels the coolant outward, generating the required head (up to 25m) to circulate the coolant through the CDU system.
The ultra-high-life friction pair material in the shaft system minimizes wear during high-speed rotation, extending the pump’s service life. The IP67 protection structure isolates the motor and internal components from external dust and moisture, ensuring stable operation in harsh environments.
The RS485 communication interface enables bidirectional data transmission between the pump and the CDU system controller, allowing for real-time monitoring of operating parameters (e.g., flow rate, temperature) and remote adjustments as needed. The φ64mm quick-install chuck facilitates secure and rapid connection to the CDU’s coolant pipelines, ensuring tight sealing and efficient fluid transfer.
Based on the industry convention of 1.5L/min flow rate corresponding to 1KW heat dissipation capacity, the OWP-BL3000H-A3-1’s maximum flow rate of 400L/min (at 25m head) provides a reference for 适配 CDU host heat dissipation systems.
Calculating the approximate heat load range: 400L/min ÷ 1.5L/(min·KW) ≈ 266.7KW. This suggests the pump is suitable for CDU systems with a host heat dissipation capacity ranging from approximately 260KW to 270KW.
It is important to note that this range is for reference only. Actual 适配 depends on specific CDU system configurations, including pipeline length, resistance, coolant type, and operating temperature. For systems with higher pipeline resistance or different coolant properties, the effective flow rate may vary, and adjustments to the selection should be made based on detailed system requirements.
Users are advised to conduct a comprehensive assessment of their CDU system’s heat load, pressure loss, and installation constraints to confirm the pump’s suitability.
Q1: What is the warranty period for the OWP-BL3000H-A3-1 electronic coolant circulation pump?
A1: Two years.
Q2: Can the OWP-BL3000H-A3-1 be customized to meet specific CDU system requirements?
A2: Yes, customization is supported.
Q3: What is the lead time for orders of the OWP-BL3000H-A3-1 pump?
A3: 20 working days.
Company Details
Business Type:
Manufacturer
Year Established:
2016
Total Annual:
12,000,000-15,000,000
Employee Number:
150~220
Ecer Certification:
Verified Supplier
Changzhou Bextreme Shell Motor Technology Co., Ltd. is a professional and pioneering manufacturing enterprise exclusively dedicated to the R&D, production, and sales of Brushless DC (BLDC) motor products. Since our establishment in 2016, we have remained deeply committed to advancing BLDC... Changzhou Bextreme Shell Motor Technology Co., Ltd. is a professional and pioneering manufacturing enterprise exclusively dedicated to the R&D, production, and sales of Brushless DC (BLDC) motor products. Since our establishment in 2016, we have remained deeply committed to advancing BLDC...
Get in touch with us
Leave a Message, we will call you back quickly!