Payment Terms | ,L/C,T/T |
Supply Ability | 100KM/Week |
Delivery Time | 7-30 days based on different qty |
Packaging Details | Rolls, Wooden Drums, Steel Drums, Reels or customized |
Usage | Access Control System |
Insulation | XLPE PE PVC |
Voltage | 0.6/1kV |
Length | Customized |
Conductor Material | Copper |
Packing | Neutral Carton Packing or Customized |
Brand Name | Zhongdong |
Certification | ISO9001, CE, CCC, RoHS, VDE, cUL, CSA |
Place of Origin | Hebei,China |
View Detail Information
Explore similar products
1 Core 0.6kv 1kv Fire Proof Cable Copper Conductor XLPE Insulated Fire Resistant
Steel Wire Armoured Fire Resistant Cable 0.6 1.0kV Two Core Heat Proof
0.6 KV 1KV Halogen Free Fire Resistant Cable Indoor Outdoor Electrical Cable
0.6/1kV Fire Resistant Power Cable CU/ XLPE/ PVC 07V-Z IEC 60332-3C IEC 60331
Product Specification
Payment Terms | ,L/C,T/T | Supply Ability | 100KM/Week |
Delivery Time | 7-30 days based on different qty | Packaging Details | Rolls, Wooden Drums, Steel Drums, Reels or customized |
Usage | Access Control System | Insulation | XLPE PE PVC |
Voltage | 0.6/1kV | Length | Customized |
Conductor Material | Copper | Packing | Neutral Carton Packing or Customized |
Brand Name | Zhongdong | Certification | ISO9001, CE, CCC, RoHS, VDE, cUL, CSA |
Place of Origin | Hebei,China |
Halogen-Free Flame-Resistant Cable NXXH N2XH-J N2XH-O
1. N2XH Cable Series
Core Applications:
Petrochemical processing units (reactor jackets, distillation columns)
Steel mill conveyor systems (blast furnace zones, rolling mills)
Aerospace engine compartment wiring
Technical Characteristics:
Continuous service temperature: -40°C to +250°C
Halogen-free flame retardant (IEC 60332-3C compliant)
Oil/fuel resistance (per ASTM D471)
Cross-linked polyethylene (XLPE) insulation
2. N2XH-J Cable Model
Specialized Features:
Mechanically enhanced jacket for vibration-prone applications
EMI shielding (85dB attenuation @ 1GHz)
Flexible multi-conductor design (up to 50 cores)
Typical Deployment:
Automotive testing rigs (powertrain dynamometers)
Semiconductor wafer processing equipment
High-speed rail signal transmission
3. N2XH-O Cable Model
Unique Advantages:
Oxygen-free copper conductors (99.99% purity)
Radiation-resistant properties (10^6 Gy tolerance)
Moisture-blocking layers for marine applications
Critical Use Cases:
Nuclear facility control circuits
Deep-sea ROV tether systems
Cryogenic plant instrumentation
1. N2XH Cable Structure
Conductor: Typically composed of high-purity copper or aluminum, annealed for flexibility and low resistance.
Insulation: Cross-linked polyethylene (XLPE) insulation provides excellent thermal resistance (up to 90°C) and dielectric strength.
Shielding: A concentric copper tape or braid shield minimizes electromagnetic interference (EMI).
Jacket: Thermoplastic or thermosetting material (e.g., PVC or LSZH) offers abrasion resistance and flame retardancy.
2. N2XH-J Cable Structure
Conductor: Similar to NXXH but may include additional stranding for enhanced flexibility.
Insulation: XLPE with higher dielectric breakdown voltage, suitable for industrial high-voltage applications.
Armor: Steel-wire or tape armor protects against mechanical stress (e.g., rodent damage or crushing).
Outer Jacket: Reinforced with fiberglass or aramid yarn for tensile strength in harsh environments.
3. N2XH-O Cable Structure
Conductor: Copper with silver plating for improved conductivity in corrosive environments.
Insulation: Silicone rubber insulation for extreme temperature resilience (-60°C to +200°C).
Shielding: Dual-layer shielding (aluminum foil + copper braid) for superior EMI protection.
Jacket: Fluoropolymer (e.g., PTFE) resists UV, chemicals, and moisture, ideal for outdoor installations.
Dimensions- Number of cores X cross-section | Design | Construction of the individual keep the handlers safe | The outer diameter | thickness of insulation | shell thickness | Resistance to keep the handlers safe at 20°C | Weight Cu | weight of cable |
rated | about | rated | rated | max. | about | |||
Nx mm² | nx mm | mm | mm | mm | Q/km | kg/km | kg/km | |
1×1,5 | RE | 1×1,38 | 54 | 138 | 15 | 1,210 | 15,403 | 43 |
1×4 | RE | 1×2,25 | 64 | 225 | 20 | 461 | 5,869 | 75 |
1×16 | RM | 7×1,70 | 91 | 500 | 36 | 115 | 1,464 | 202 |
1×25 | RM | 7×2,13 | 11 | 610 | 48 | 727 | 925 | 302 |
1×70 | RM | 19×2,17 | 15 | 1,010 | 84 | 268 | 341 | 745 |
1×95 | RM | 19×2,52 | 17 | 1,190 | 97 | 193 | 246 | 986 |
1×185 | RM | 37×2,52 | 23 | 1,620 | 172 | 991 | 126 | 1888 |
1×300 | RM | 61x2,50 | 28 | 2,060 | 234 | 601 | 77 | 2945 |
2×1,5 | RE | 1×1,38 | 9 | 138 | 38 | 1,210 | 15,403 | 120 |
2×2,5 | RE | 1×1,78 | 10 | 178 | 45 | 741 | 9,433 | 154 |
2×16 | RM | 7×1,70 | 16 | 500 | 106 | 115 | 1,464 | 563 |
2×25 | RM | 7×2,13 | 20 | 610 | 152 | 727 | 925 | 840 |
2×35 | RM | 7×2,52 | 22 | 720 | 179 | 524 | 667 | 1106 |
2×120 | RM | 37×2,03 | 36 | 1,300 | 423 | 153 | 195 | 3343 |
2x300 | RM | 61x2,50 | 55 | 2,060 | 939 | 601 | 77 | 8072 |
3×1,5 | RE | 1×1,38 | 9 | 138 | 44 | 1,210 | 15,403 | 135 |
3×2,5 | RE | 1×1,78 | 10 | 178 | 51 | 741 | 9,433 | 181 |
3×4 | RE | 1×2,25 | 11 | 225 | 60 | 461 | 5,869 | 242 |
3×10 | RE | 1×3,56 | 14 | 357 | 83 | 183 | 2,330 | 464 |
3×16 | RM | 7×1,70 | 17 | 500 | 122 | 115 | 1,464 | 697 |
N2XH | ||||||||
3×35 | RM | 7×2,52 | 23 | 720 | 208 | 524 | 667 | 1393 |
3×50 | RM | 19×1,83 | 26 | 830 | 256 | 387 | 493 | 1847 |
3×70 | RM | 19×2,17 | 31 | 1,010 | 343 | 268 | 341 | 2666 |
3×95 | RM | 19×2,52 | 36 | 1,190 | 417 | 193 | 246 | 3535 |
3×120 | RM | 37x2,03 | 38 | 1,300 | 474 | 153 | 195 | 4322 |
3×185 | RM | 37x2,52 | 48 | 1,620 | 740 | 991 | 126 | 6742 |
3×300 | RM | 61×2,50 | 59 | 2,060 | 1,079 | 601 | 77 | 10522 |
1. What is N2XH cable?
N2XH is a European standard (EN) halogen-free flame-retardant power cable, where "N" denotes non-spreading flame and "XH" indicates cross-linked polyethylene (XLPE) insulation. The J/O suffixes differentiate between rigid (Class 1) and flexible (Class 5) conductor versions.
2. Key features of N2XH-J/O cables?
Fire safety: FRNC (Flame Retardant Non-Corrosive) sheath reduces smoke/toxic gas emission during fire incidents
Material: Copper conductor + XLPE insulation + LSOH (Low Smoke Zero Halogen) sheath
Certification: CE/TUV certified, compliant with EN 60332-3, IEC 60754-1 standards
3. Typical applications?
Public buildings (hospitals, hotels)
Industrial plants (chemical/oil facilities)
Transport systems (metro, railways)
4. Voltage rating & temperature range?
Rated voltage: 0.6/1kV
Operating temp: -40°C to +90°C (fixed installation)
Short-circuit withstand: +250°C (5 sec max)
5. Installation precautions?
Minimum bending radius: 12× cable diameter
Avoid parallel routing with high-voltage cables (keep ≥300mm spacing)
Use proper glanding tools for shield termination
6. How to identify conductor classes?
N2XH-J: Class 1 solid conductor (rigid)
N2XH-O: Class 5 stranded conductor (flexible)
7. Advantage over PVC cables?
50% lower smoke density in fires (IEC 61034 test)
No corrosive halogen gases (IEC 60754-1 compliant)
8. Maintenance recommendations?
Annual insulation resistance test (>20MΩ·km)
Visual inspection for sheath damage in corrosive environments
Company Details
Business Type:
Manufacturer
Year Established:
2006
Total Annual:
150000000-200000000
Employee Number:
400~500
Ecer Certification:
Verified Supplier
Zhongdong Cable Co., Ltd. is a professional cables and wires manufacturer in China since 2006, the company covers an area of over 38000 square meters, 30 advanced cable production lines and 40 sets of testing equipment, we have a strong R&D ability with almost 100 Senior technical perso... Zhongdong Cable Co., Ltd. is a professional cables and wires manufacturer in China since 2006, the company covers an area of over 38000 square meters, 30 advanced cable production lines and 40 sets of testing equipment, we have a strong R&D ability with almost 100 Senior technical perso...
Get in touch with us
Leave a Message, we will call you back quickly!