| DC Output Voltage | 122.5 VDC (97-145 VDC adjustable) |
| Max Current Per Phase | 78 ARMS |
| Max AC Power | 18 kVA |
| Hold Up Time | >10 ms; VOUT > 41 VDC |
| AC Output Voltage | 230 VAC / 400 VAC 3 phase (Y) |
| Max DC Power | 14.4 kW |
View Detail Information
Explore similar products
60KA Lightning Outdoor Power Cabinet IP55 Data Communication Cabinets
Customizable Outdoor Electrical Cabinet with IP55/IP65/IP66 Protection, 60KA
48V 3000W Rectifier Module High Efficiency DC Power Supply for Telecom Systems
IP55 Outdoor Waterproof Electrical Cabinet 2000W Heat Dissipation
Product Specification
| DC Output Voltage | 122.5 VDC (97-145 VDC adjustable) | Max Current Per Phase | 78 ARMS |
| Max AC Power | 18 kVA | Hold Up Time | >10 ms; VOUT > 41 VDC |
| AC Output Voltage | 230 VAC / 400 VAC 3 phase (Y) | Max DC Power | 14.4 kW |
| High Light | 110 VDC Rectiverter Power Core ,18 KVA Rectiverter Power System ,1ph or 3ph Rectiverter Power Core | ||
The Eltek Rectiverter Power Core 110 VDC 18 kVA is a versatile power system that combines both AC and DC feeds into a single common unit. It provides AC backup power for 3-phase or single-phase AC loads, and 110 VDC power for DC loads and battery charging. Total output power for both AC and DC output is limited to a maximum of 24 kW, with AC and DC output limits configurable according to the attached load.
The 3-port converter simultaneously provides power for AC and DC loads. During mains outage, the Rectiverter 110/1200 HE feeds AC loads using energy stored in the battery. Part No. CIOR1207.1xxx.
| Max Current | 128 A | Max Capacity | 24 kW |
|---|---|---|---|
| Product Name | Rectiverter Power System | Hold Up Time | >10 ms; VOUT > 41 VDC |
| AC Output | 1 Phase or 3 Phase | Frequency Default | 50 Hz |
| Current Max Per Phase | 28 A | DC Output | 122.5 VDC / 97–145 VDC |
| DC Power | 14 kW Max | Output Features | Short Circuit Proof, Over Voltage Shutdown |
| Models / Ordering Information | 24 kW, 400 V 3ph | |
|---|---|---|
| Product Family | CIOR1207.1xxx | |
| AC Output Data | ||
| Voltage (default) / (adjustable range)1) | 230 VAC / 200–240 VAC; 400 VAC 3-phase (Y) / 346–415 VAC | |
| Frequency (default inverter mode) | 50 Hz (adaptive) | |
| Frequency (settable inverter mode) | 50 Hz, 60 Hz, or last synced 50/60 Hz (adaptive) | |
| Power maximum (continuous / overload <15 s) | 14.4 kW (18 kVA) / 24 kVA | |
| Current maximum/phase (continuous / overload <15 s) | 78 ARMS / 104.4 ARMS | 26 ARMS / 34.8 ARMS |
| Current (maximum) quick trip/phase (20 ms) | 384 A (6 × nominal) | 128 A (6 × nominal) |
| Hold up (voltage dips) before switching to battery | > 5 ms @ 14.4 kW load | |
| THD | < 1.5% at resistive load | |
| Output features | Fuse in L and N, Hot pluggable | |
| DC Output Data | ||
| Voltage (default) / (adjustable range) | 122.5 VDC / 97–145 VDC | |
| Power (maximum @ nominal input) | 14.4 kW2) | |
| Current (maximum @ VOUT ≤ 108 VDC) | 133 A2) | |
| Hold up time, maximum output power | >10 ms; VOUT > 41 VDC | |
| Output features | Short circuit proof, Over voltage shutdown, Bulk DC output connection to M8 bolt | |
| Input Data | ||
| AC Mains Input Voltage | (3-phase Y) 185–275 VAC; (single phase) 320–475 VAC; (3-phase Y) | |
| AC Current/phase (at nominal output voltage) | 84–144 ARMS4) | 28–48 ARMS4) |
| Frequency (default: sync range) | 47–53 & 57–63 Hz | |
| Frequency (settable: sync range) | 47–53 Hz, 57–63 Hz, or both (adaptive) | |
| Power Factor / THD | > 0.99 at 50% load or more / < 3.5% | |
| DC Voltage nominal / extended range (no overload)3) | 102–145 VDC / 90–102 VDC | |
| DC Current (maximum) | 150 A / 216 A during overload (15 s) | |
| Input features | Fuse in L and N, Hot pluggable, Varistor, Hot pluggable; AC input individual screw terminals 10 mm² for L1, L2, L3, or L1, L1, L1 + N & PE; Bulk DC input connection to M8 bolt; Bulk DC battery connection to M8 bolt | |
| Options | ||
| Control and monitoring (see Smartpack2 datasheet) | Smartpack2, including industrial basic & I/O monitor type 2 | |
| 1-pole AC distribution (L connection directly on MCB) | 1–18 pc, 2–20 A, C or B characteristics | 1–18 pc, 2–20 A, C or B characteristics |
| 3-pole AC distribution (L1–L3 connection directly on MCB) | — | 1–6 pc, 2–20 A, C or B characteristics |
1) Adjustable range depends on module type. 2) Maximum power and current depend on input voltage and load conditions. 3) Extended range operation without overload. 4) Depending on module type.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2025-04-02
Total Annual:
1000-1500
Employee Number:
50~100
Ecer Certification:
Verified Supplier
Shenzhen Zhongchen Huahui Technology Co., Ltd.Professional System Integration Solution Provider for Telecom, Power Utilities, Railway & Metro Who We Are Shenzhen Zhongchen Huahui Technology Co., Ltd. is a high-tech enterprise integrating advanced customized R&D, professional manufacturing, a... Shenzhen Zhongchen Huahui Technology Co., Ltd.Professional System Integration Solution Provider for Telecom, Power Utilities, Railway & Metro Who We Are Shenzhen Zhongchen Huahui Technology Co., Ltd. is a high-tech enterprise integrating advanced customized R&D, professional manufacturing, a...
Get in touch with us
Leave a Message, we will call you back quickly!