| Payment Terms | T/T |
| Supply Ability | 50 sets/month |
| Delivery Time | 5-10 working days |
| Packaging Details | carton |
| Test voltage range | 0-600V |
| Test current range | 5mA-20A |
| Power factor | -1.000~1.000 |
| Power freqency | 0.5Hz~ 100KHz |
| Accuracy | ±0.2% |
| Input | AC100V ~ 240V, 50Hz/60Hz |
| Brand Name | Pego Electronics |
| Model Number | HP510 |
| Certification | CNAS Calibration Certificate |
| Place of Origin | China |
View Detail Information
Explore similar products
IEC60332-1 Single Wire Flammability Test Apparatus 45 Degree Burner Angle
Manual Electrical Safety Test Equipment Stainless Steel Inclined Plane Device
Cold Bend Test Apparatus SUS304 Electrical Safety Test Equipment
1.1m Length Luminaire / Short Circuit Test Chain 63%Cu 37%Zn Material IEC60598-1
Product Specification
| Payment Terms | T/T | Supply Ability | 50 sets/month |
| Delivery Time | 5-10 working days | Packaging Details | carton |
| Test voltage range | 0-600V | Test current range | 5mA-20A |
| Power factor | -1.000~1.000 | Power freqency | 0.5Hz~ 100KHz |
| Accuracy | ±0.2% | Input | AC100V ~ 240V, 50Hz/60Hz |
| Brand Name | Pego Electronics | Model Number | HP510 |
| Certification | CNAS Calibration Certificate | Place of Origin | China |
| High Light | 0.2 Grade Accuracy Digital Power Meter ,0.5Hz to 1000KHz Bandwidth Power Analyzer ,5" IPS LCD Display Electrical Parameter Measuring Instrument | ||
This is a multifunctional digital power meter for measuring the power of single - phase (1P/2W) AC and DC power supplies. The test frequency range of this product can reach DC 0.5Hz - 100kHz. It uses a 5" IPS LCD display screen, has a 5 - digit measurement display, enables simultaneous measurement of multiple parameters, and possesses high - precision measurement capability. At the same time, it has functions such as waveform display (voltage/current/power), integral measurement function, measurement and analysis of each harmonic (measurement at 50/60Hz meets the requirements of IEC61000 - 4 - 7), external sensor input terminals, and various communication interfaces to assist users in achieving clear, convenient and accurate power measurement.
|
Input indicators |
|||
|
Item |
Voltage |
Current |
|
|
Input type |
Floating input via resistor divider |
Direct input or sensor input |
|
|
Input impedance |
Approx. 2MΩ |
Direct input:: Approx. 500mΩ (200mA and below range) Approx. 50mΩ (0.5A and above range) Sensor input: about 100KΩ |
|
|
Measurement range (RMS) |
15V, 30V, 60V, 150V, 300V, 600V |
Direct input: 5mA, 10mA, 20mA, 50mA, 100mA, 200mA, 0.5A, 1A, 2A, 5A, 10A, 20A Sensor input: 50mV, 100mV, 200mV, 500mV, 1V, 2V, 5V, 10V |
|
|
Maximum continuous input |
1.5kV Peak or 1kV RMS, whichever is smaller |
30A Peak or 20A RMS, whichever is smaller (200mA and below) 100A Peak or 30A RMS, whichever is smaller (0.5A and above) |
|
|
Voltage and current accuracy |
|||
|
Item |
Specification |
||
|
DC |
±(0.1% reading + 0.2% range) |
||
|
0.5Hz ≤ f < 45Hz |
±(0.1% reading + 0.2% range) |
||
|
45Hz ≤ f ≤ 66Hz |
±(0.1% reading + 0.05% range) |
||
|
66Hz < f ≤ 1kHz |
±(0.1% reading + 0.2% range) |
||
|
1kHz < f ≤ 10kHz |
±[(0.07×f)% reading + 0.3% range] |
||
|
Temperature coefficient |
5 to 18°C or 28 to 40°C: Add ±0.03% of reading. |
||
|
When the power filter is on |
<45Hz: add 0.5% of the reading; 45~66Hz: add 0.2% of the count |
||
|
Crest Factor Impact |
The range error when the crest factor is 6 is twice the range error when the crest factor is 3. |
||
|
Effect of temperature change after zero calibration or range change |
Add 0.02%/°C of range to DC voltage accuracy. Add the following values to DC current accuracy: 200mA and below range: 5uA/°C; 0.5A and above range: 500uA/°C. External sensor input: 1mV/°C. |
||
|
Active power measurement accuracy |
|||
|
Item |
Specification |
||
|
Measurement conditions |
Temperature: 23±5℃ Humidity: 30~75%RH (no condensation) After 30 minutes of preheating Input waveform: stable DC or sine wave Common mode voltage: 0V Crest factor: 3 Power filter: OFF Frequency filter: On to measure ≤200Hz voltage or current Zero calibration after measuring range change |
||
|
DC |
±(0.1% reading + 0.2% range) |
||
|
0.5Hz ≤ f < 45Hz |
±(0.3% reading + 0.2% range) |
||
|
45Hz ≤ f ≤ 66Hz |
±(0.1% reading + 0.05% range) |
||
|
66Hz < f ≤ 1kHz |
±(0.2% reading + 0.2% range) |
||
|
1kHz < f ≤ 10kHz |
±(0.1% reading + 0.3% range) ±[0.067×(f-1)% reading] |
||
|
10kHz < f ≤ 100kHz |
±(0.5% reading + 0.5% range) ±[0.09×(f-10)% reading] |
||
|
Temperature coefficient |
5~18℃ or 28~40℃: add ±0.03% of reading.
|
||
|
When the power filter is on |
<45Hz: add 1% of reading; 45~66Hz: add 0.3% of count. |
||
|
Crest Factor Impact |
The range error when the peak factor is 6 is twice the range error when the peak factor is 3. |
||
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Trading Company
Year Established:
2014
Ecer Certification:
Verified Supplier
Pego Electronics is founded by PEGO GROUP in 2011, a professional high-tech enterprise engaged in developing, marketing and service for electronic test equipment. Our business scope includes IP testing equipment, dust chamber, pendulum and vertical impact testing equipment, flame test apparatus,&nbs... Pego Electronics is founded by PEGO GROUP in 2011, a professional high-tech enterprise engaged in developing, marketing and service for electronic test equipment. Our business scope includes IP testing equipment, dust chamber, pendulum and vertical impact testing equipment, flame test apparatus,&nbs...