{"title":"Programmable Logic Controller Electronics Training Kits With Three Phase Four","imgUrl":"https:\/\/img.chinax.com\/nimg\/b5\/1f\/c5b38fcca566072a5a417c29dd34-200x200-1\/programmable_logic_controller_electronics_training_kits_with_three_phase_four.jpg","attrs":{"Type":"Electrical and electronic basis examination&training equipment series","End user":"Professional School,Secondary School","Payment Terms":"T\/T","Item name":"Primary electrical lighting skills assessment training device"}}
{"title":"PLC Training Equipment Electrical Trainer Kit Educational Experiment Box","imgUrl":"https:\/\/img.chinax.com\/nimg\/99\/a7\/80f1538d657504fe73ccae4d791e-200x200-1\/plc_training_equipment_electrical_trainer_kit_educational_experiment_box.jpg","attrs":{"Inputvoltage":"24V DC","Productname":"PLC Training Equipment","Certification":"ISO9001\/ISO45001\/ISO14001,TUV","Place of Origin":"HENAN,CHINA"}}
{"title":"Educational Versatile Electrical Training Box For C2000 Series Digital Signal","imgUrl":"https:\/\/img.chinax.com\/nimg\/e6\/0f\/f3a12a344bf6b305f1d3c31676e1-200x200-1\/educational_versatile_electrical_training_box_for_c2000_series_digital_signal_processor_and_power_conversion.jpg","attrs":{"Category":"Educational Training Equipment","Dimensions":"470*390*200mm","Function":"Laboratory equipment","Warranty":"1 year"}}
{"title":"Electrical And Electronics Training Equipment Safety For Practical Education","imgUrl":"https:\/\/img.chinax.com\/nimg\/8d\/01\/27097df79d66b5ab5b251d42683a-200x200-1\/electrical_and_electronics_training_equipment_safety_for_practical_education.jpg","attrs":{"Brand Name":"RUIMU","Model Number":"RM-G005A","Place of Origin":"Henan,China","Minimum Order Quantity":"1 Unit"}}
{"title":"Digital And Analog Breadboard Trainer Box With Centralized Modules Circuit Board","imgUrl":"https:\/\/img.chinax.com\/nimg\/1a\/55\/e347ce8857cf255c7996c1a97b49-200x200-1\/digital_and_analog_breadboard_trainer_box_with_centralized_modules_circuit_board.jpg","attrs":{"Warranty":"1 year","Purpose":"To provide hands-on training and practical experience","Material":"Metal","User Level":"Suitable for beginners to advanced students"}}
{"title":"Textbook Aligned Modular Power Electrical Training Kit Platform With Overload","imgUrl":"https:\/\/img.chinax.com\/nimg\/c6\/cd\/f64f151a74212f0953132b856134-200x200-1\/textbook_aligned_modular_power_electrical_training_kit_platform_with_overload_protection.jpg","attrs":{"Inputvoltagerange":"110V - 240V","Brand Name":"RM","Model Number":"RM-F102","Certification":"ISO9001\/ISO45001\/ISO14001,TUV"}}
{"title":"Three Phase Four Wire Input Electrical Laboratory Equipment For Hands On","imgUrl":"https:\/\/img.chinax.com\/nimg\/94\/ba\/db56b0bb35f5e90fdceead196f6d-200x200-1\/three_phase_four_wire_input_electrical_laboratory_equipment_for_hands_on_operation.jpg","attrs":{"Dimensions":"1700mm * 720mm * 1630mm","Material":"High-quality ABS plastic and metal components","Warrantyperiod":"1 year","Powersupply":"220V AC, 50Hz"}}
Input power supply: Three-phase four-wire (or three-phase five-wire) ~380V±10% 50Hz
Power supply output: Equipped with leakage protector, overload and short-circuit protection devices.
Three-phase four-wire 380V output with output voltage indicated by three voltmeters
~220V output through safety sockets
+24V/2A DC regulated power supply output
+5V/1A DC regulated power supply output
±12V/1A DC regulated power supply output
DC voltage: 0~10V adjustable output; DC current: 0~20mA adjustable output
Working environment: Temperature -10℃~+40℃, Relative humidity <85% (25℃), Altitude <400m
Device capacity: <1.5KVA
Weight: <110Kg
Overall dimensions: Not less than 1600mm*680mm*1600mm
Safety protection: Equipped with leakage current protection device, in compliance with national safety standards
III. Basic Configuration and Functional Parameters of the Training Device
The training device consists of a control panel, a training desk, a host training module, training units (including a wealth of simulated training objects of industrial field equipment), a frequency converter hanging box, a touch screen hanging box, etc.
(I) Training Desk
The frame of the training desk adopts an industrial aluminum profile structure, and the tabletop is a fireproof, waterproof and wear-resistant high-density board; it adopts an integrated design of computer desk and training desk. The lower part of the training desk is equipped with a drawer cabinet, a computer host cabinet, a keyboard tray, etc., with a firm structure and an elegant appearance. The overall dimensions are approximately 1600mm*680mm*1600mm.
(II) Control Panel Parameters
Input power supply: Three-phase four-wire (or three-phase five-wire) ~380V±10% 50Hz.
AC power supply output: Three-phase four-wire 380V output with output voltage indicated by three voltmeters, equipped with leakage protector, overload and short-circuit protection devices.
~220V output through safety sockets.
DC power supply output
(1) +24V/2A DC regulated power supply output;
(2) ±12V/1A DC regulated power supply output;
(3) +5V/1A DC regulated power supply output;
(4) Adjustable DC voltage: 0~10V adjustable output;
(5) Adjustable DC current: 0~20mA;
★5. Laboratory Safety Management Platform Software (Genuine software, copyright certificate verification and demonstration are required on the bidding site)
1) The power management terminal consists of a 2.8-inch TFT color LCD screen and a data acquisition module, which displays electrical parameters such as three-phase current, three-phase voltage, three-phase active power, three-phase reactive power, power factor and frequency of the experimental bench in real time.
2) A correct password is required to start the power supply when the power management terminal is booted to avoid misoperation by students;
3) After logging in with the correct password, you can set timed on/off, overvoltage alarm on/off, overvoltage alarm value, undervoltage alarm on/off, undervoltage alarm value, overcurrent alarm on/off, overcurrent alarm value, low balance alarm on/off.
4) After logging in, you can view alarm records, recharge electricity, clear remaining electricity, etc.; you can also change the login password, set the system time synchronization mode, and configure the network via hotspot;
5) The power switch status of the power management terminal can be inquired through the mobile APP, and the power supply of students' experimental benches can be turned on and off individually; the function of turning on or off the power supply of all experimental benches; the function of timing reservation for turning on and off the power supply of experimental benches.
6) The APP software displays device temperature, power consumption histogram, three-phase total active power, total reactive power, phase A active power, phase A reactive power, phase A power factor, phase B active power, phase B reactive power, phase B power factor, phase C active power, phase C reactive power, phase C power factor and grid frequency in real time.
7) The APP software can set overvoltage alarm on/off, overvoltage alarm value, undervoltage alarm on/off, undervoltage alarm value, overcurrent alarm on/off, overcurrent alarm value, low balance alarm on/off.
8) The APP software can recharge the electricity meter equipment.
9) The device can be shared with other members through the APP.
10) The operations of the APP software are synchronized to the power management terminal in real time.