China 35mm Standard Kilowatt Hour Meter 3 Phase Four Wire DIN Rail , Active & Reactive
China 35mm Standard Kilowatt Hour Meter 3 Phase Four Wire DIN Rail , Active & Reactive

  1. China 35mm Standard Kilowatt Hour Meter 3 Phase Four Wire DIN Rail , Active & Reactive

35mm Standard Kilowatt Hour Meter 3 Phase Four Wire DIN Rail , Active & Reactive

  1. MOQ: 1pc
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T or western Union
Supply Ability 10000pcs per month
Delivery Time 5-30 working days after receiving payment
Packaging Details standard export carton
Wire Four
Basic Current 5A
Max Current 5A
Year of Manufacture 2016
Customzation Yes
Dimension 125*88*73mm
Brand Name YOMIN
Model Number YEM421JC
Certification CE/ROHS
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T or western Union Supply Ability 10000pcs per month
Delivery Time 5-30 working days after receiving payment Packaging Details standard export carton
Wire Four Basic Current 5A
Max Current 5A Year of Manufacture 2016
Customzation Yes Dimension 125*88*73mm
Brand Name YOMIN Model Number YEM421JC
Certification CE/ROHS Place of Origin China
High Light din rail watt hour meter din rail energy meter

 

35mm Standard Three Phase Four Wire DIN Rail Energy Meter , Active & Reactive KWH Meter

 

Product Description

 

Model YEM421JC three phase four wire electronic DIN rail active and reactive integration energy meter is a kind of new style three phase four wire active energy meter, it adopt micro-electronics technique, and imported large scale integrate circuit, use advanced technique of digital and SMT techniques, etc. The meter completely accord with relevant technical requirements of class 1 three phase active energy meter stipulated in international standard IEC 62053-21 and class 2 three phase reactive energy meter stipulated in international standard IEC 62053-23. It can accurate and directly measure 50Hz or 60Hz active and reactive energy consumption from three phase four wire AC electricity net, it can display total energy consumption by step motor type impulse register. This meter has seven digits LCD displays shows active energy. It has following features: good reliability, small volume, light weight, specious nice appearance, convenient installation, etc.

 

Specification

 

Model

Accuracy

Reference Voltage

Current Specification

Starting Current

Insulation Performance

YEM421JC

Active class 1

Reactive class 2

3x127/220V

3x230/400V

5(30)A

10(60)A

20(100)A

0.02A

0.04A

0.08A

AC voltage 4kv for 1 min, 1.2/50us waveform impulse voltage 6kv

* If you need different reference voltage or current specification, please advisory our sales personnel.

 

Competitive Advantage

 

1. 35mm standard DIN rail installation, complying with standard DIN EN50022. Or front board installed (mounting holes center distance 63 mm), users can choose any one by themselves.

 

2. Ten pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.

 

3. 7 digits LCD display, 6+1 digits(999999. 1kWh),may select 5+2 digits display. (Please specified when ordering)

 

4. Standard configuration one port of active pulse output passive and one port of reactive pulse output passive(polarity),The output rate are 0.01, 0.1, 1, 10kWh or kvarh/Pulse. Users can choose any one by themselves. May select one port of active pulse output passive and one port of reactive pulse output passive (nonpolarity). And contact with all kind of AMR system conveniently,Complying with standard IEC 62053-31 and DIN 43864. (Please specified when ordering)

 

5. Five LED instructions power supply state and signal of active energy impulse and reactive energy impulse.

 

6. Automatic detection the direction of the flow of load current. And instructions by one LED.

 

7. Single direction three components measure three phase four wire active and reactive energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21and IEC 62053-23.

 

8. Standard configuration type S wiring (Inlet from top, outlet from bottom), directly connect operation, may select use CT (Product Configuration code is IC) and PT&CT (Product Configuration code is HC) for operation.

 

9. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is JF).

 

Dimension

 

      

 

Wiring Diagram

                             

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Trading Company

  • Year Established:

    2002

  • Total Annual:

    30000000-40000000

  • Employee Number:

    200~300

  • Ecer Certification:

    Site Member

Established in 2002, YUEQING YOMIN ELECTRIC CO., LTD(before named Zhengjiang Yomin Electric Co., Ltd , founded in 1996) is a manufacturer and exporter specialized in the research, development and production and service of different kinds of Single-phase and three-phase mechanical watt-hour meter, lo... Established in 2002, YUEQING YOMIN ELECTRIC CO., LTD(before named Zhengjiang Yomin Electric Co., Ltd , founded in 1996) is a manufacturer and exporter specialized in the research, development and production and service of different kinds of Single-phase and three-phase mechanical watt-hour meter, lo...

+ Read More

Get in touch with us

  • Reach Us
  • YUEQING YOMIN ELECTRIC CO., LTD
  • Qiaoqian Industry Area, Liushi Town, Yueqing City, Zhejiang Province, China
  • https://www.electric-energymeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement