| Payment Terms | MoneyGram,Western Union,T/T,D/P,D/A,L/C |
| Supply Ability | 100 |
| Delivery Time | 2 weeks |
| Packaging Details | wooden box |
| Parameter Category | Parameter Name |
| Basic Configuration | Maximum Displacement Safety Ceiling* |
| Brand Name | Rexroth |
| Model Number | PV7-1X/16-20RE01MC5-16WG PV7-1X/10-20RE01MW0-10WH PV7-1X/63-94RE07KD0-08 |
| Certification | ISO |
| Place of Origin | Germany |
View Detail Information
Explore similar products
PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot
PV7-1X/63-94RE07MC0-08-P80Q114 PV7-1X/40-45RE37MC5-16WH PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH PV7-1X/63-71RE07KC0-16 PV7-1X/10-20RE01MC3-10 German
PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16 Hydraulic
Product Specification
| Payment Terms | MoneyGram,Western Union,T/T,D/P,D/A,L/C | Supply Ability | 100 |
| Delivery Time | 2 weeks | Packaging Details | wooden box |
| Parameter Category | Parameter Name | Basic Configuration | Maximum Displacement Safety Ceiling* |
| Brand Name | Rexroth | Model Number | PV7-1X/16-20RE01MC5-16WG PV7-1X/10-20RE01MW0-10WH PV7-1X/63-94RE07KD0-08 |
| Certification | ISO | Place of Origin | Germany |
| High Light | Rexroth PV7 vane pump ,German imported vane pump ,original stock vane pump | ||
PV7-1X/16-20RE01MC5-16WG
PV7-1X/10-20RE01MW0-10WH
PV7-1X/63-94RE07KD0-08 Rexroth Pilot PV7 Vane Pump Imported from Germany with Original Stock
| Question | Answer |
| What is the model range of the direct-acting PV7 series? | PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 |
| What is the model range of the pilot-operated PV7 series? | PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 |
| What does "1X/2X" represent in the PV7 model code? | It indicates the component series of the pump |
| What is the displacement per revolution range of the direct-acting PV7 series? | 10–25 cm³/rev |
| What is the displacement per revolution range of the pilot-operated PV7 series? | 14–150 cm³/rev |
| What is the maximum continuous working pressure of the direct-acting PV7 series? | 100 bar |
| What is the maximum continuous working pressure of the pilot-operated PV7 series? | 160 bar |
| What is the maximum peak pressure of the direct-acting PV7 series? | 120 bar (short-term overload ≤5s only) |
| What is the maximum peak pressure of the pilot-operated PV7 series? | 200 bar (short-term overload ≤5s only) |
| What is the speed range of the direct-acting PV7 series? | 600–2800 rpm (higher speed for smaller displacement models) |
| What is the speed range of the pilot-operated PV7 series? | 600–3600 rpm (higher speed for smaller displacement models) |
| What is the maximum flow rate of the direct-acting PV7 series at 1800 rpm? | 36 l/min (calculated at rated displacement) |
| What is the maximum flow rate of the pilot-operated PV7 series at 1800 rpm? | 270 l/min (calculated at rated displacement) |
| What is the volumetric efficiency of the direct-acting PV7 series under rated conditions? | ≥90% (at 160 bar, 1800 rpm, ISO VG 46 oil) |
| What is the volumetric efficiency of the pilot-operated PV7 series under rated conditions? | ≥92% (at 160 bar, 1800 rpm, ISO VG 46 oil) |
| What is the total efficiency of the direct-acting PV7 series under nominal operation? | ≥80% (includes mechanical & volumetric efficiency) |
| What is the total efficiency of the pilot-operated PV7 series under nominal operation? | ≥82% (includes mechanical & volumetric efficiency) |
| What is the suction pressure range of the PV7 series? | -0.8 to +1 bar (absolute pressure: 0.2–1.1 bar) |
| What types of hydraulic fluids are compatible with the PV7 series? | Mineral oil (HLP) and synthetic oil (HETG/HEES); use FKM seals for synthetic fluids |
| What is the fluid viscosity range for PV7 series operation? | 10–1000 mm²/s (operation); 2–1500 mm²/s (start-up); optimal range is 16–160 mm²/s |
| What is the fluid temperature range for PV7 series operation? | -20 to +80 °C (operation); -40 to +90 °C (storage) |
| What is the noise level of the direct-acting PV7 series at 1 m distance under rated operation? | ≤63 dB(A) |
| What is the noise level of the pilot-operated PV7 series at 1 m distance under rated operation? | ≤65 dB(A) |
| What is the mounting standard for the PV7 series? | ISO 3019-2 flange; optional foot mounting for some models |
| What type of shaft connection does the PV7 series use? | ISO 4162 splined shaft; keyed shaft available on request |
| What seal materials are available for the PV7 series? | NBR (standard, for mineral oil) and FKM (optional, for synthetic oil) |
| What is the weight range of the direct-acting PV7 series? | 8–12 kg (depends on displacement) |
| What is the weight range of the pilot-operated PV7 series? | 10–35 kg (depends on displacement and control type) |
![]()
| PV7-1X/100-150RE07MC0-08-A464 |
| PV7-1X/100-118RE07MD0-16 |
| PV7-1X/10-14RE01MN0-16 |
| PV7-1X/40-45RE37MC5-16 |
| PV7-1X/100-118RE07MC5-16 |
| PV7-1X/25-30RE01KC3-16 |
| PV7-1X/10-20RE01MC5-10WG |
| PV7-1X/25-30RE01MW0-16 |
| PV7-1X/16-20RE01MD3-16 |
| PV7-1X/16-20RE01MC0-16-P110 |
| PV7-1X/40-45RE37KD0-16-C3.1 |
| PV7-1X/63-71RE07MC5-16WH |
| PV7-1X/16-30RE01KC0-08 |
| PV7-1X/10-14RE01MD5-16 |
| PV7-1X/63-71RE07MC6-16 |
| PV7-1X/16-20RE01KD0-16 |
| PV7-1X/10-14RE01MW0-16 |
| PV7-1X/63-71RE07MC0-16-C3.1 |
| PV7-1X/16-30RE01MW0-08WH |
| PV7-1X/100-150RE07MC0-08-A446 |
| PV7-1X/25-30RE01MC5-16WG |
| PV7-1X/10-20RE01MC0-10-A497 |
| PV7-1X/100-150RE07KC0-08 |
| PV7-1X/100-150RE07MD5-08 |
| PV7-1X/25-45RE01MC0-08-P25Q50 |
| PV7-1X/40-71RE37MC5-08 |
| PV7-1X/10-14RE01KD0-16 |
| PV7-1X/16-20RE01MC0-16-P120 |
| PV7-1X/100-150RE07MW0-08WH |
| PV7-1X/16-20RE01MC5-16WG |
| PV7-1X/10-20RE01MW0-10WH |
| PV7-1X/63-94RE07KD0-08 |
| PV7-1X/63-71RE07MW0-16WH |
| PV7-1X/63-71RE07MC7-16WH |
| PV7-1X/40-45RE37MC0-16 |
| PV7-1X/63-94RE07MC0-08-P80Q114 |
| PV7-1X/40-45RE37MC5-16WH |
| PV7-1X/10-14RE01KN0-16 |
| PV7-1X/25-30RE01MC5-16WH |
| PV7-1X/63-71RE07KC0-16 |
| PV7-1X/10-20RE01MC3-10 |
| PV7-1X/16-20RE01MN0-16 |
| PV7-1X/25-45RE01MW0-08WH |
| PV7-1X/63-71RE07MN0-16 |
| PV7-1X/63-71RE07KD0-16 |
| PV7-1X/16-20RE01MC8-16 |
| PV7-1X/40-71RE37MW0-08WH |
| PV7-1X/40-45RE37MD0-16-P50Q36 |
| PV7-1X/40-45RE37MC7-16WG |
| PV7-1X/100-118RE07MN5-16 |
| PV7-1X/25-45RE01MC7-08WG |
| PV7-1X/63-71RE07MC7-16 |
| PV7-1X/100-150RE07MC3-08 |
| PV7-1X/40-45RE37KC0-16 |
| PV7-1X/63-94RE07MC5-08 |
| PV7-1X/16-20RE01MC0-16-P60Q26 |
| PV7-1X/16-20RE01MC5-16 |
| PV7-1X/40-71RE37MC5-08WG |
| PV7-1X/25-45RE01MC7-08 |
| PV7-1X/25-30RE01MW5-16WH |
| PV7-1X/10-20RE01MD0-10 |
| PV7-1X/63-71RE07MD0-16-Q90 |
| PV7-1X/16-30RE01MC3-08 |
| PV7-1X/100-150RE07MC7-08 |
| PV7-1X/100-118RE07MN0-16 |
| PV7-1X/10-20RE01MC5-10 |
| PV7-1X/25-30RE01MC5-16WH-A234 |
| PV7-1X/100-150RE07MC5-08WH |
| PV7-1X/25-30RE01MW0-16WH |
| PV7-1X/10-20RE01MC7-10WH |
| PV7-1X/25-45RE01MC5-08 |
| PV7-1X/40-45RE37MC8-16 |
| PV7-1X/16-20RE01MW0-16WH |
| PV7-1X/16-20RE01MC3-16-P50Q25 |
| PV7-1X/100-118RE07KC0-16 |
| PV7-1X/40-71RE37MC5-08WH |
| PV7-1X/100-118RE07MC6-16 |
| PV7-1X/40-71RE37MC3-08 |
| PV7-1X/40-71RE37MC7-08WH |
| PV7-1X/10-14RE01MW0-16WH |
| PV7-1X/10-20RE01MC3-10-A497 |
| PV7-1X/16-20RE01MC3-16 |
| PV7-1X/16-20RE01MC5-16WH |
| PV7-1X/63-71RE07MC3-06-A460 |
| PV7-1X/16-30RE01MC5-08WH |
| PV7-1X/10-14RE01MC0-16-P100 |
| PV7-1X/63-94RE07MC5-08WH |
| PV7-1X/10-14RE01MC3-16 |
FAQ:
One
Q: What is the allowable range for the Displacement Adjustment Range parameter?
A: It must be set within the factory-specified min-max displacement range of the Rexroth PV7 pump to avoid mechanical damage.
Two
Q: Why do I need to set the Nominal Displacement Calibration Offset?
A: This offset corrects deviations between the factory-calibrated displacement and the actual measured displacement in your system.
Three
Q: Can the Minimum Displacement Lock Threshold be adjusted after locking?
A: No, this threshold is locked after initial setting to ensure idle-load protection and prevent accidental adjustments.
Four
Q: What is the purpose of the Maximum Displacement Safety Ceiling?
A: It acts as a hard upper limit to prevent the pump from reaching displacement levels that cause overload and component wear.
Five
Q: How does the Displacement Step Adjustment Increment affect flow control?
A: A smaller increment enables finer flow regulation, which is ideal for applications requiring precise flow adjustments.
Pressure Control
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...
Get in touch with us
Leave a Message, we will call you back quickly!