| Payment Terms | MoneyGram,Western Union,T/T,D/P,D/A,L/C |
| Supply Ability | 100 |
| Delivery Time | 2 weeks |
| Packaging Details | wooden box |
| Basic Configuration | Displacement Step Adjustment Increment |
| Pressure Control | Pressure Compensation Hysteresis Value |
| Brand Name | Rexroth |
| Model Number | PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 |
| Certification | ISO |
| Place of Origin | Germany |
View Detail Information
Explore similar products
PV7-1X/16-20RE01MC5-16WG PV7-1X/10-20RE01MW0-10WH PV7-1X/63-94RE07KD0-08 Rexroth
PV7-1X/63-94RE07MC0-08-P80Q114 PV7-1X/40-45RE37MC5-16WH PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH PV7-1X/63-71RE07KC0-16 PV7-1X/10-20RE01MC3-10 German
PV7-1X/16-20RE01MN0-16 PV7-1X/25-45RE01MW0-08WH PV7-1X/63-71RE07MN0-16 Hydraulic
Product Specification
| Payment Terms | MoneyGram,Western Union,T/T,D/P,D/A,L/C | Supply Ability | 100 |
| Delivery Time | 2 weeks | Packaging Details | wooden box |
| Basic Configuration | Displacement Step Adjustment Increment | Pressure Control | Pressure Compensation Hysteresis Value |
| Brand Name | Rexroth | Model Number | PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 |
| Certification | ISO | Place of Origin | Germany |
| High Light | Rexroth vane pump PV7 series ,Pilot operated vane pump Germany ,Imported Rexroth PV7 hydraulic pump | ||
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany
| Parameter/Property Category | Direct-Acting (PV7-A) Series | Pilot-Operated (PV7-C/D/N/W) Series | Unit | Remarks |
| Model Range | PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 | PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 | #VALUE! | 1X/2X=component series; 06/14/20=frame size |
| Displacement per Revolution | 10–25 | 14–150 | cm³/rev | Displacement varies by specific model suffix |
| Max. Continuous Working Pressure | 100 | 160 | bar | PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar |
| Max. Peak Pressure | 120 | 200 | bar | Short-term (≤5s) overload only |
| Speed Range | 600–2800 | 600–3600 | rpm | Higher speed for smaller displacement models |
| Max. Flow Rate (at 1800 rpm) | 36 | 270 | l/min | Calculated at rated displacement |
| Volumetric Efficiency (Rated Condition) | ≥90% | ≥92% | % | At 160 bar, 1800 rpm, ISO VG 46 oil |
| Total Efficiency (Nominal Operation) | ≥80% | ≥82% | % | Includes mechanical & volumetric efficiency |
| Suction Pressure Range | 1 | -0.8 to +1 | bar | Absolute pressure: 0.2–1.1 bar |
| Fluid Compatibility | Mineral oil (HLP), synthetic oil (HETG/HEES) | Mineral oil (HLP), synthetic oil (HETG/HEES) | - | Use FKM seals for synthetic fluids |
| Fluid Viscosity Range | 10–1000 (operation); 2–1500 (start-up) | 10–1000 (operation); 2–1500 (start-up) | mm²/s | Optimal: 16–160 mm²/s |
| Fluid Temperature Range | -20 to +80 | -20 to +80 | °C | Storage: -40 to +90 °C |
| Noise Level (1 m Distance, Rated Operation) | ≤63 | ≤65 | dB(A) | Pilot-operated models have optimized noise reduction |
| Mounting Standard | ISO 3019-2 flange | ISO 3019-2 flange | - | Optional foot mounting for some models |
| Shaft Connection | ISO 4162 splined shaft | ISO 4162 splined shaft | - | Keyed shaft available on request |
| Seal Material | NBR (standard); FKM (optional) | NBR (standard); FKM (optional) | - | NBR for mineral oil; FKM for synthetic oil |
![]()
| PV7-1X/100-150RE07KC0-08 |
| PV7-1X/100-150RE07MD5-08 |
| PV7-1X/25-45RE01MC0-08-P25Q50 |
| PV7-1X/40-71RE37MC5-08 |
| PV7-1X/10-14RE01KD0-16 |
| PV7-1X/16-20RE01MC0-16-P120 |
| PV7-1X/100-150RE07MW0-08WH |
| PV7-1X/16-20RE01MC5-16WG |
| PV7-1X/10-20RE01MW0-10WH |
| PV7-1X/63-94RE07KD0-08 |
| PV7-1X/63-71RE07MW0-16WH |
| PV7-1X/63-71RE07MC7-16WH |
| PV7-1X/40-45RE37MC0-16 |
| PV7-1X/63-94RE07MC0-08-P80Q114 |
| PV7-1X/40-45RE37MC5-16WH |
| PV7-1X/10-14RE01KN0-16 |
| PV7-1X/25-30RE01MC5-16WH |
| PV7-1X/63-71RE07KC0-16 |
| PV7-1X/10-20RE01MC3-10 |
| PV7-1X/16-20RE01MN0-16 |
| PV7-1X/25-45RE01MW0-08WH |
| PV7-1X/63-71RE07MN0-16 |
| PV7-1X/63-71RE07KD0-16 |
| PV7-1X/16-20RE01MC8-16 |
| PV7-1X/40-71RE37MW0-08WH |
| PV7-1X/40-45RE37MD0-16-P50Q36 |
| PV7-1X/40-45RE37MC7-16WG |
| PV7-1X/100-118RE07MN5-16 |
| PV7-1X/25-45RE01MC7-08WG |
| PV7-1X/63-71RE07MC7-16 |
| PV7-1X/100-150RE07MC3-08 |
| PV7-1X/40-45RE37KC0-16 |
| PV7-1X/63-94RE07MC5-08 |
| PV7-1X/16-20RE01MC0-16-P60Q26 |
| PV7-1X/16-20RE01MC5-16 |
| PV7-1X/40-71RE37MC5-08WG |
| PV7-1X/25-45RE01MC7-08 |
| PV7-1X/25-30RE01MW5-16WH |
| PV7-1X/10-20RE01MD0-10 |
| PV7-1X/63-71RE07MD0-16-Q90 |
| PV7-1X/16-30RE01MC3-08 |
| PV7-1X/100-150RE07MC7-08 |
| PV7-1X/100-118RE07MN0-16 |
| PV7-1X/10-20RE01MC5-10 |
| PV7-1X/25-30RE01MC5-16WH-A234 |
| PV7-1X/100-150RE07MC5-08WH |
| PV7-1X/25-30RE01MW0-16WH |
| PV7-1X/10-20RE01MC7-10WH |
| PV7-1X/25-45RE01MC5-08 |
| PV7-1X/40-45RE37MC8-16 |
| PV7-1X/16-20RE01MW0-16WH |
| PV7-1X/16-20RE01MC3-16-P50Q25 |
| PV7-1X/100-118RE07KC0-16 |
| PV7-1X/40-71RE37MC5-08WH |
| PV7-1X/100-118RE07MC6-16 |
| PV7-1X/40-71RE37MC3-08 |
| PV7-1X/40-71RE37MC7-08WH |
| PV7-1X/10-14RE01MW0-16WH |
| PV7-1X/10-20RE01MC3-10-A497 |
| PV7-1X/16-20RE01MC3-16 |
| PV7-1X/16-20RE01MC5-16WH |
| PV7-1X/63-71RE07MC3-06-A460 |
| PV7-1X/16-30RE01MC5-08WH |
| PV7-1X/10-14RE01MC0-16-P100 |
| PV7-1X/63-94RE07MC5-08WH |
| PV7-1X/10-14RE01MC3-16 |
| PV7-1X/40-45RE37MD0-16 |
| PV7-1X/100-118RE07MC7-16WH |
| PV7-1X/25-45RE01MC5-08WH |
| PV7-1X/16-20RE01MC0-16 |
| PV7-1X/63-71RE07MC5-16WG |
| PV7-1X/63-71RE07KC3-16 |
| PV7-1X/10-20RE01MC5-10WH |
| PV7-1X/16-20RE01MC7-16 |
| PV7-1X/10-14RE01MC7-16 |
| PV7-1X/63-94RE07MC0-08 |
| PV7-1X/16-20RE01MC0-16-P100Q29 |
| PV7-1X/25-30RE01MC0-16-P100Q36 |
| PV7-1X/40-45RE37MW5-16WH |
FAQ:
Six
Q: What is the recommended range for the Standby Pressure Trigger Threshold?
A: Set it to 20–50% of the rated working pressure to activate low-power standby mode efficiently.
Seven
Q: Can the Maximum Working Pressure Dynamic Limit exceed the pump’s rated pressure?
A: No, this limit must never exceed the rated pressure specified in the Rexroth PV7 Technical Manual.
Eight
Q: How does adjusting the Pressure Relief Response Delay help the system?
A: A longer delay suppresses hydraulic shock and pressure surges, ensuring smoother system operation.
Nine
Q: What happens if the Pressure Compensation Hysteresis Value is set too low?
A: The pressure control system will become overly sensitive, leading to frequent pressure fluctuations.
Ten
Q: When will the Low-Pressure Leakage Alarm Threshold trigger an alert?
A: It triggers an alarm when the system pressure drops below the threshold during long-term idle operation, indicating potential leakage.
Flow Regulation
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...
Get in touch with us
Leave a Message, we will call you back quickly!