China factories

Chat Now Send Email
China factory - Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

  • China ,Fujian
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot
China PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot

  1. China PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot
  2. China PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot

PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16 Pilot

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms MoneyGram,Western Union,T/T,D/P,D/A,L/C
Supply Ability 100
Delivery Time 2 weeks
Packaging Details wooden box
Basic Configuration Displacement Step Adjustment Increment
Pressure Control Pressure Compensation Hysteresis Value
Brand Name Rexroth
Model Number PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16
Certification ISO
Place of Origin Germany

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms MoneyGram,Western Union,T/T,D/P,D/A,L/C Supply Ability 100
Delivery Time 2 weeks Packaging Details wooden box
Basic Configuration Displacement Step Adjustment Increment Pressure Control Pressure Compensation Hysteresis Value
Brand Name Rexroth Model Number PV7-1X/63-71RE07MW0-16WH PV7-1X/63-71RE07MC7-16WH PV7-1X/40-45RE37MC0-16
Certification ISO Place of Origin Germany
High Light Rexroth vane pump PV7 seriesPilot operated vane pump GermanyImported Rexroth PV7 hydraulic pump

PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH    
PV7-1X/40-45RE37MC0-16 Pilot operated Rexroth vane pump PV7 series imported from Germany

Parameter/Property Category Direct-Acting (PV7-A) Series Pilot-Operated (PV7-C/D/N/W) Series Unit Remarks
Model Range PV7-1X/06-10RA01MA0-10, PV7-2X/20-25RA01MA0-10 PV7-1X/14-20RE01MC0-16, PV7-1X/100-118RE07KD0-16 #VALUE! 1X/2X=component series; 06/14/20=frame size
Displacement per Revolution 10–25 14–150 cm³/rev Displacement varies by specific model suffix
Max. Continuous Working Pressure 100 160 bar PV7-A: ≤100 bar; PV7-C/D/N/W: ≤160 bar
Max. Peak Pressure 120 200 bar Short-term (≤5s) overload only
Speed Range 600–2800 600–3600 rpm Higher speed for smaller displacement models
Max. Flow Rate (at 1800 rpm) 36 270 l/min Calculated at rated displacement
Volumetric Efficiency (Rated Condition) ≥90% ≥92% % At 160 bar, 1800 rpm, ISO VG 46 oil
Total Efficiency (Nominal Operation) ≥80% ≥82% % Includes mechanical & volumetric efficiency
Suction Pressure Range 1 -0.8 to +1 bar Absolute pressure: 0.2–1.1 bar
Fluid Compatibility Mineral oil (HLP), synthetic oil (HETG/HEES) Mineral oil (HLP), synthetic oil (HETG/HEES) - Use FKM seals for synthetic fluids
Fluid Viscosity Range 10–1000 (operation); 2–1500 (start-up) 10–1000 (operation); 2–1500 (start-up) mm²/s Optimal: 16–160 mm²/s
Fluid Temperature Range -20 to +80 -20 to +80 °C Storage: -40 to +90 °C
Noise Level (1 m Distance, Rated Operation) ≤63 ≤65 dB(A) Pilot-operated models have optimized noise reduction
Mounting Standard ISO 3019-2 flange ISO 3019-2 flange - Optional foot mounting for some models
Shaft Connection ISO 4162 splined shaft ISO 4162 splined shaft - Keyed shaft available on request
Seal Material NBR (standard); FKM (optional) NBR (standard); FKM (optional) - NBR for mineral oil; FKM for synthetic oil

PV7-1X/100-150RE07KC0-08
PV7-1X/100-150RE07MD5-08
PV7-1X/25-45RE01MC0-08-P25Q50
PV7-1X/40-71RE37MC5-08
PV7-1X/10-14RE01KD0-16
PV7-1X/16-20RE01MC0-16-P120
PV7-1X/100-150RE07MW0-08WH
PV7-1X/16-20RE01MC5-16WG
PV7-1X/10-20RE01MW0-10WH
PV7-1X/63-94RE07KD0-08
PV7-1X/63-71RE07MW0-16WH
PV7-1X/63-71RE07MC7-16WH
PV7-1X/40-45RE37MC0-16
PV7-1X/63-94RE07MC0-08-P80Q114
PV7-1X/40-45RE37MC5-16WH
PV7-1X/10-14RE01KN0-16
PV7-1X/25-30RE01MC5-16WH
PV7-1X/63-71RE07KC0-16
PV7-1X/10-20RE01MC3-10
PV7-1X/16-20RE01MN0-16
PV7-1X/25-45RE01MW0-08WH
PV7-1X/63-71RE07MN0-16
PV7-1X/63-71RE07KD0-16
PV7-1X/16-20RE01MC8-16
PV7-1X/40-71RE37MW0-08WH
PV7-1X/40-45RE37MD0-16-P50Q36
PV7-1X/40-45RE37MC7-16WG
PV7-1X/100-118RE07MN5-16
PV7-1X/25-45RE01MC7-08WG
PV7-1X/63-71RE07MC7-16
PV7-1X/100-150RE07MC3-08
PV7-1X/40-45RE37KC0-16
PV7-1X/63-94RE07MC5-08
PV7-1X/16-20RE01MC0-16-P60Q26
PV7-1X/16-20RE01MC5-16
PV7-1X/40-71RE37MC5-08WG
PV7-1X/25-45RE01MC7-08
PV7-1X/25-30RE01MW5-16WH
PV7-1X/10-20RE01MD0-10
PV7-1X/63-71RE07MD0-16-Q90
PV7-1X/16-30RE01MC3-08
PV7-1X/100-150RE07MC7-08
PV7-1X/100-118RE07MN0-16
PV7-1X/10-20RE01MC5-10
PV7-1X/25-30RE01MC5-16WH-A234
PV7-1X/100-150RE07MC5-08WH
PV7-1X/25-30RE01MW0-16WH
PV7-1X/10-20RE01MC7-10WH
PV7-1X/25-45RE01MC5-08
PV7-1X/40-45RE37MC8-16
PV7-1X/16-20RE01MW0-16WH
PV7-1X/16-20RE01MC3-16-P50Q25
PV7-1X/100-118RE07KC0-16
PV7-1X/40-71RE37MC5-08WH
PV7-1X/100-118RE07MC6-16
PV7-1X/40-71RE37MC3-08
PV7-1X/40-71RE37MC7-08WH
PV7-1X/10-14RE01MW0-16WH
PV7-1X/10-20RE01MC3-10-A497
PV7-1X/16-20RE01MC3-16
PV7-1X/16-20RE01MC5-16WH
PV7-1X/63-71RE07MC3-06-A460
PV7-1X/16-30RE01MC5-08WH
PV7-1X/10-14RE01MC0-16-P100
PV7-1X/63-94RE07MC5-08WH
PV7-1X/10-14RE01MC3-16
PV7-1X/40-45RE37MD0-16
PV7-1X/100-118RE07MC7-16WH
PV7-1X/25-45RE01MC5-08WH
PV7-1X/16-20RE01MC0-16
PV7-1X/63-71RE07MC5-16WG
PV7-1X/63-71RE07KC3-16
PV7-1X/10-20RE01MC5-10WH
PV7-1X/16-20RE01MC7-16
PV7-1X/10-14RE01MC7-16
PV7-1X/63-94RE07MC0-08
PV7-1X/16-20RE01MC0-16-P100Q29
PV7-1X/25-30RE01MC0-16-P100Q36
PV7-1X/40-45RE37MW5-16WH

FAQ:

Six
Q: What is the recommended range for the Standby Pressure Trigger Threshold?
A: Set it to 20–50% of the rated working pressure to activate low-power standby mode efficiently.

Seven
Q: Can the Maximum Working Pressure Dynamic Limit exceed the pump’s rated pressure?
A: No, this limit must never exceed the rated pressure specified in the Rexroth PV7 Technical Manual.

Eight
Q: How does adjusting the Pressure Relief Response Delay help the system?
A: A longer delay suppresses hydraulic shock and pressure surges, ensuring smoother system operation.

Nine
Q: What happens if the Pressure Compensation Hysteresis Value is set too low?
A: The pressure control system will become overly sensitive, leading to frequent pressure fluctuations.

Ten
Q: When will the Low-Pressure Leakage Alarm Threshold trigger an alert?
A: It triggers an alarm when the system pressure drops below the threshold during long-term idle operation, indicating potential leakage.

Flow Regulation

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Total Annual:

    1 million-10 millon

  • Employee Number:

    >50

  • Ecer Certification:

    Verified Supplier

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...

+ Read More

Get in touch with us

  • Reach Us
  • Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
  • Nan'an, Fujian Province, China
  • https://www.electrichydpump.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement