| Payment Terms | MoneyGram,Western Union,T/T,D/A,D/P,L/C |
| Supply Ability | 100 |
| Delivery Time | 2 weeks |
| Packaging Details | wooden box |
| Fuel | Gasoline |
| Condition | New |
| Origin | China |
| Maximum Pressure | 315 bar |
| Mounting Type | Flange Mounting |
| Weight | 8.5 kg - 45 kg |
| Hs Code | 8413503190 |
| Pressure | Standard, High Pressure |
| Pressure Rating | 280 bar |
| Brand Name | Rexroth |
| Model Number | 4WRZ10W6-25-7X/6EG24N9K4/D3M 4WRZ10W6-25-7X/6EG24N9K4/M 4WRZ10E3-85-7X/6EG24N9TK4/D3M |
| Certification | ISO |
| Place of Origin | German |
View Detail Information
Explore similar products
Rexroth Proportional Directional Valve 4WRA Series with 280 bar Nominal Pressure
German Rexroth Proportional Hydraulic Directional Valve 4WRA Series with 30 l
German Original Rexroth Proportional Directional Valve with 280 bar Maximum
REXROTH Proportional Directional Valve with Direct-Operated Design and Spring
Product Specification
| Payment Terms | MoneyGram,Western Union,T/T,D/A,D/P,L/C | Supply Ability | 100 |
| Delivery Time | 2 weeks | Packaging Details | wooden box |
| Fuel | Gasoline | Condition | New |
| Origin | China | Maximum Pressure | 315 bar |
| Mounting Type | Flange Mounting | Weight | 8.5 kg - 45 kg |
| Hs Code | 8413503190 | Pressure | Standard, High Pressure |
| Pressure Rating | 280 bar | Brand Name | Rexroth |
| Model Number | 4WRZ10W6-25-7X/6EG24N9K4/D3M 4WRZ10W6-25-7X/6EG24N9K4/M 4WRZ10E3-85-7X/6EG24N9TK4/D3M | Certification | ISO |
| Place of Origin | German | ||
| High Light | Rexroth hydraulic proportional valve ,German Rexroth solenoid valve ,Rexroth directional valve with warranty | ||
4WRZ10W6-25-7X/6EG24N9K4/D3M
4WRZ10W6-25-7X/6EG24N9K4/M
4WRZ10E3-85-7X/6EG24N9TK4/D3M Imported original proportional valve, German Rexroth directional solenoid valve
| Processing & Customization | yes | type | proportional valve |
| material | cast steel | model | 4WRZ10W6-25-7X/6EG24N9K4/D3M 4WRZ10W6-25-7X/6EG24N9K4/M 4WRZ10E3-85-7X/6EG24N9TK4/D3M |
| brand | REXROTH | Scope of Application | hydraulic system |
| Product Alias | Proportional directional valve | Applicable Medium | oil products |
| Applicable Temperature | Normal temperature (℃) ℃ | Nominal Pressure | Normal pressure (MPa) MPa |
| Nominal Diameter | 6-way diameter (mm) mm | Installation type | Threaded installation |
| Operating Temperature | room temperature | Type (channel location) | Straight through type |
![]()
| 4WRZ10W9-25-7X/6EG24N9EK4/M |
| 4WRZ10W9-25-7X/6EG24N9K4/D3M |
| 4WRZ10W9-25-7X/6EG24N9K4/M |
| 4WRZ10W8-85-7X/6EG24N9ETK4/M |
| 4WRZ10W8-85-7X/6EG24N9EK4/D3M |
| 4WRZ10W8-85-7X/6EG24N9EK4/M |
| 4WRZ10W8-85-7X/6EG24N9K4/D3M |
| 4WRZ10E50-70/6EG24N9TK4/M |
| 4WRZ10W6-25-7X/6EG24N9EK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9K4/D3M |
| 4WRZ10W8-50-7X/6EG24N9EK4/M |
| 4WRZ10W8-50-7X/6EG24N9K4/D3M |
| 4WRZ10W8-50-7X/6EG24N9K4/M |
| 4WRZ10W8-25-7X/6EG24N9EK4/M |
| 4WRZ10W8-25-7X/6EG24N9K4/D3M |
| 4WRZ10W8-25-7X/6EG24N9K4/M |
| 4WRZ10W6-85-7X/6EG24N9TK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9TK4/M |
| 4WRZ10W6-85-7X/6EG24N9ETK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9ETK4/M |
| 4WRZ10W6-85-7X/6EG24N9EK4/D3M |
| 4WRZ10W6-85-7X/6EG24N9EK4/M |
| 4WRZ10W6-85-7X/6EG24N9K4/M |
| 4WRZ10W6-25-7X/6EG24N9EK4/M |
| 4WRZ10W6-50-7X/6EG24N9TK4/D3M |
| 4WRZ10W6-50-7X/6EG24N9TK4/M |
| 4WRZ10W6-50-7X/6EG24N9ETK4/D3M |
| 4WRZ10W6-50-7X/6EG24N9ETK4/M |
| 4WRZ10W6-50-7X/6EG24N9EK4/D3M |
| 4WRZ10W6-50-7X/6EG24N9EK4/M |
| 4WRZ10W6-50-7X/6EG24N9K4/D3M |
| 4WRZ10W6-50-7X/6EG24N9K4/M |
| 4WRZ10W6-25-7X/6EG24N9TK4/D3M |
| 4WRZ10W6-25-7X/6EG24N9TK4/M |
| 4WRZ10W6-25-7X/6EG24N9ETK4/D3M |
| 4WRZ10W6-25-7X/6EG24N9ETK4/M |
| 4WRZ10W8-85-7X/6EG24N9K4/M |
| 4WRZ10W6-25-7X/6EG24N9K4/D3M |
| 4WRZ10W6-25-7X/6EG24N9K4/M |
| 4WRZ10E3-85-7X/6EG24N9TK4/D3M |
| 4WRZ10E3-85-7X/6EG24N9ETK4/D3M |
| 4WRZ10E3-85-7X/6EG24N9ETK4/M |
| 4WRZ10E3-85-7X/6EG24N9EK4/D3M |
| 4WRZ10E3-85-7X/6EG24N9EK4/M |
| 4WRZ10E3-85-7X/6EG24N9K4/D3M |
| 4WRZ10E3-85-7X/6EG24N9K4/M |
| 4WRZ10E3-50-7X/6EG24N9TK4/D3M |
| 4WRZ10E3-50-7X/6EG24N9TK4/M |
| 4WRZ10E3-50-7X/6EG24N9ETK4/D3M |
| 4WRZ10E3-50-7X/6EG24N9ETK4/M |
| 4WRZ10E3-50-7X/6EG24N9EK4/D3M |
| 4WRZ10E3-50-7X/6EG24N9EK4/M |
| 4WRZ10E3-50-7X/6EG24N9K4/M |
| 4WRZ10E3-50-7X/6EG24N9K4/D3M |
| 4WRZ10E3-25-7X/6EG24N9EK4/M |
| 4WRZ10E3-25-7X/6EG24N9K4/D3M |
| 4WRZ10E3-25-7X/6EG24N9K4/M |
| -4WRZ10E1-85-7X/6EG24N9TK4/M |
| 4WRZ10E1-85-7X/6EG24N9ETK4/D3M |
| 4WRZ10E1-85-7X/6EG24N9ETK4/M |
| 4WRZ10E1-85-7X/6EG24N9EK4/D3M |
| 4WRZ10E1-85-7X/6EG24N9EK4/M |
| 4WRZ10E1-85-7X/6EG24N9K4/D3M |
| 4WRZ10E1-85-7X/6EG24N9K4/M |
| 4WRZ10E1-50-7X/6EG24N9TK4/D3M |
| 4WRZ10E1-85-7X/6EG24N9TK4/D3M |
| 4WRZ10E3-85-7X/6EG24N9TK4/M |
| 4WRZ10E1-50-7X/6EG24N9EK4/M |
| 4WRZ10E85-7X/6EG24N9ETK4/D3M |
| 4WRZ10E1-50-7X/6EG24N9ETK4/D3M |
| 4WRZ10E1-50-7X/6EG24N9ETK4/M |
| 4WREE10WA75-2X/G24K31/F1V |
| 4WREE10WA50-2X/G24K31/F1V |
| 4WREE10WA25-2X/G24K31/F1V |
| 4WREE10EA75-2X/G24K31/F1V |
| 4WREE10EA25-2X/G24K31/F1V |
| 4WREE10W1-75-2X/G24K31/F1V |
| 4WRZ10E50-7X/6EG24N9TK4/D3M |
| 4WRZ10E85-7X/6EG24N9K4/D3M |
| 4WRZ10E85-7X/6EG24N9EK4/M |
| 4WRZ10E85-7X/6EG24N9EK4/D3M |
| 4WRZ10E85-7X/6EG24N9TK4/M |
| 4WRZ10E1-25-7X/6EG24N9EK4/M |
| 4WRZ10E85-7X/6EG24N9TK4/D3M |
| 4WRZ10E1-25-7X/6EG24N9K4/D3M |
| 4WRZ10E1-25-7X/6EG24N9EK4/D3M |
| 4WRZ10E1-50-7X/6EG24N9K4/D3M |
| 4WRZ10E85-7X/6EG24N9K4/M |
| 4WRZ10E85-7X/6EG24N9ETK4/M |
| 4WRZ10E1-50-7X/6EG24N9K4/M |
| 4WRZ10E1-50-7X/6EG24N9EK4/D3M |
| 4WREE10W1-25-2X/G24K31/F1V |
FAQ:
1. Q: How to calibrate the spool position feedback of the 4WRZ10?
A: Use the manufacturer’s calibration software (e.g., Rexroth IndraWorks) or external tools to adjust the zero point and full-scale output, ensuring alignment between the electrical signal and spool travel.
2. Q: What is the recommended filter fineness for the hydraulic system with 4WRZ10?
A: A minimum filter fineness of 10 μm (β10 ≥ 75) is required to protect the valve’s precision components from contamination.
3. Q: Can the 4WRZ10 be mounted in a manifold?
A: Yes, it is compatible with manifold mounting (ISO 4401 manifolds) for space-saving and centralized hydraulic system designs.
4. Q: How to prevent leakage at the hydraulic connections?
A: Use O-rings or flat gaskets (compatible with hydraulic fluid) and ensure proper port cleaning before assembly; avoid over-tightening bolts.
5. Q: What is the correct way to connect the drain port (if applicable)?
A: The drain port (marked “R” or “L”) should be connected to the tank with minimal backpressure (< 3 bar) to ensure proper solenoid cooling and seal lubrication.
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...
Get in touch with us
Leave a Message, we will call you back quickly!