Payment Terms | MoneyGram,Western Union,T/T,D/P,D/A,L/C |
Supply Ability | 100 |
Delivery Time | 2 weeks |
Packaging Details | wooden box |
+85267220981 | |
Yli97584@gmail.com | |
Shaft Diameter | 25 mm |
Origin | Germany |
Theory | Rotary Pump |
Seal Type | Lip seal |
Warranty | Free Warranty |
Pressure | High Pressure |
Shaft Type | Keyed |
Power | Electric |
Rotation | 0.2-cp can be transported in reverse |
Brand Name | Rexroth |
Model Number | PGH4-2X/063RE07VE4 PGH4-2X/063RR07VU2 PGH4-2X/063LE07VU2 PGH4-2X/063LR07VU2 PGH4-2X/080RE07VU2 |
Certification | ISO |
Place of Origin | German |
View Detail Information
Explore similar products
German Rexroth Industrial High-Pressure Hydraulic Gear Pump 280 Bar with
Rexroth A4VSO180 Piston Pump 3000 rpm High Pressure for Hydraulics
A10VO71DFRI/31R-PSC64K02-S0225 A10VSO71FR1/31R-PPA12N00 Hydraulic Piston Pump
Rexroth A10VSO Hydraulic Piston Pump 280 Bar High Pressure
Product Specification
Payment Terms | MoneyGram,Western Union,T/T,D/P,D/A,L/C | Supply Ability | 100 |
Delivery Time | 2 weeks | Packaging Details | wooden box |
+85267220981 | Yli97584@gmail.com | ||
Shaft Diameter | 25 mm | Origin | Germany |
Theory | Rotary Pump | Seal Type | Lip seal |
Warranty | Free Warranty | Pressure | High Pressure |
Shaft Type | Keyed | Power | Electric |
Rotation | 0.2-cp can be transported in reverse | Brand Name | Rexroth |
Model Number | PGH4-2X/063RE07VE4 PGH4-2X/063RR07VU2 PGH4-2X/063LE07VU2 PGH4-2X/063LR07VU2 PGH4-2X/080RE07VU2 | Certification | ISO |
Place of Origin | German | ||
High Light | Steel Mill Hydraulic Gear Pump ,Industrial Metallurgy Gear Pump ,Quantitative Rexroth Gear Pump |
PGH4-2X/063RE07VE4
PGH4-2X/063RR07VU2
PGH4-2X/063LE07VU2
PGH4-2X/063LR07VU2
PGH4-2X/080RE07VU2 Steel mill industrial metallurgy German Rexroth hydraulic pump quantitative high-pressure gear pump
+85267220981 | yli97584@gmail.com | ||
Brand Name | Rexroth | Place of Origin | Germany |
Warranty | 12 Months | Video outgoing-inspection | Provided |
Machinery Test Report | Provided | Application | Machinery Repair Shops |
Material | Iron | Condition | Oringal |
Type | PGH4-2X/063RE07VE4 PGH4-2X/063RR07VU2 PGH4-2X/063LE07VU2 PGH4-2X/063LR07VU2 PGH4-2X/080RE07VU2 | Quality | 100% Tested Great Performance |
Certification | ISO | Feature | Long Life Low Noise |
Function | Filter Diesel Oil | Power | Hydraulic Power |
Payment Term | T/T 100% |
PGH5-2X/160RE07VU2 | PGH4-2X/050RE11VE4 | PGH3-1X/016RF07MK0 |
PGH5-2X/125RR11VU2 | PGH4-2X/040RE11VU2 | PGH3-1X/016RE07ME4 |
PGH5-2X/125RE11VU2 | PGH4-2X/032RR11VU2 | PGH3-1X/016LE07MU2 |
PGH5-2X/125RE11VE4 | PGH4-2X/032RE11VU2 | PGH3-1X/010RE07MU2 |
PGH5-2X/100RE11VE4 | PGH4-2X/032RE11VE4 | PGH2-X/008LR07VU2 |
PGH5-2X/100LF11VK0 | PGH4-2X/025RE11VU2 | PGH2-X/008LE07VU2 |
PGH5-2X/080RR18VU2 | PGH4-2X/025RE11VU2 | PGH2-X/006RE07VU2 |
PGH5-2X/080RE11VE4 | PGH4-2X/025RE11VE4 | PGH2-X/005RR07VU2 |
PGH5-2X/063RR11VU2 | PGH4-2X/020RE11WU2 | PGH2-2X/008RR07WU2 |
PGH5-2X/063RE11VU2 | PGH4-2X/020RE11VU2 | PGH2-2X/008RE07WU2 |
PGH5-2X/063RE11VE4 | PGH4-2X/020LR18VU2 | PGH2-2X/008RE07VU2 |
PGH5-21/160RE07VU2 | PGH4-21/050RE11VE4 | PGH2-2X/008LR07VU2 |
PGH5-21/125RE11VE4 | PGH4-21/040RE11VU2 | PGH2-2X/008LE07VU2 |
PGH5-21/080RE11VU2 | PGH4-21/032RE11VE4 | PGH2-2X/006RE07VU2 |
PGH4-3X/050RE11VU2 | PGH4-21/025RE11VU2 | PGH2-2X/005RR07VU2 |
PGH4-3X/020RR11VU2 | PGH3-2X/016RE07VU2 | PGH2-2X/005RE07VU2 |
PGH4-2X/100RE07VU2 | PGH3-2X/013RR07VU2 | PGH2-1X/006RE07MU2 |
PGH4-2X/080RF07VK0 | PGH3-2X/013RE07VU2 | PGH2-1X/006RE07ME4 |
PGH4-2X/080LF47VK0 | PGH3-2X/011RE07VU2 | PGH2-1X/005RE07MU2 |
PGH4-2X/063RE07VE4 | PGH3-2X/011LR07VU2 | PGH2-1X/005LE07MU2 |
PGH4-2X/050RE11VU2 | PGH3-2X/011LE07VU2 |
FAQ:
What precautions should be taken during the installation of PGH Series Gear Pumps?
• Ensure the pump’s rotational direction matches the system’s requirements (reverse rotation can cause internal component damage).
• Keep the suction line length within 1 meter and avoid sharp bends to prevent insufficient oil suction.
• Tighten the flange bolts to the torque specified in the manual (typically 18-22 N·m for standard models) to avoid oil leakage or housing deformation.
3. How to resolve abnormal noise from a PGH Series Gear Pump during operation?
First, check if the hydraulic oil level is too low (topping up to the standard level if needed); second, inspect for air bubbles in the oil circuit (bleeding the system to remove air); finally, check if the bearing is worn (replacing the bearing if there is excessive radial play).
4. How often should maintenance be performed on PGH Rexroth Gear Pumps?
For general industrial applications, routine inspection (checking oil level, temperature, and leakage) should be conducted monthly; oil change and filter replacement are recommended every 6 months or after 2000 hours of operation; a comprehensive disassembly and inspection of the pump should be carried out every 2-3 years.
5. Can PGH Rexroth Gear Pumps be used in high-temperature environments for a long time?
No. The maximum allowable long-term operating temperature of PGH Rexroth Gear Pumps is 80°C. Prolonged use in environments exceeding this temperature will accelerate the aging of internal seals and bearings, significantly reducing the pump's service life and even causing sudden failures.
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...
Get in touch with us
Leave a Message, we will call you back quickly!