How does the DR Pressure Control (Pressure Cut-Off) work?
The DR control maintains a constant system pressure by changing the swashplate angle. When the system pressure reaches the spring-set value on the DR valve, the control mechanism acts to reduce the pump's displacement, delivering only the flow required to maintain the set pressure. This functionality is sometimes referred to as "Pressure Cut-Off" in some pump literature. It's important to note that a system safety valve is still essential because the DR control's response is relatively slow compared to sudden pressure shocks; the safety valve handles transient pressure spikes.
What is the difference between DRG and DP control types?
Both DRG and DP are forms of constant pressure control, but they are designed for different appliions:
DRG (Remote Pressure Control): Allows the pressure setpoint for the pump to be adjusted remotely via an external pressure control valve.
DP (Multi-Pump Parallel Pressure Control): Specifically designed for systems where multiple pumps work in parallel. It contains an additional element (a variable orifice, valve 5) that mechanically links to the swangle. This design automatically compensates for differences between pumps, ensuring they share the load equally and operate at the same swashplate angle when working together at the set pressure. The DP control has a larger control deviation (~6.5 bar) compared to DRG (~3 bar).
Why might multiple A4VSO DR pumps in parallel cause system vibration?
When multiple pumps with standard DR controls are set to the same pressure and run in parallel, slight inherent differences in their response characteristics and pressure settings can cause them to not reduce displacement (cut off) at exactly the same time and rate. This lack of synchronization can lead to interactions between the pumps, resulting in pressure fluctuations and potentially causing severe pipeline vibration.
Bearing: Features a specially designed, long-life, high-precision full roller bearing
Shaft: Through-shaft design allows for mounting additional pumps to form a multi-pump group
For more information about this product, please contact us via WhatsApp at +85267220981 or email at Yli97584@gmail.com.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...