China R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M Pilot operated proportional
China R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M Pilot operated proportional

  1. China R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M Pilot operated proportional

R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M Pilot operated proportional

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms Western Union,T/T,D/P,D/A,L/C
Supply Ability 100
Delivery Time 2 weeks
Packaging Details wooden box
Rated Flow​ 200 L/min​ (at Δp = 10 bar per control land)
Max. Flow​ Approx. 460 L/min​
Supply Voltage​ 24V DC​ (18...35 VDC)
Control Signal​ ±10 V DC​ (Analog voltage input, /A1​ suffix)
Feedback​ Electrical spool position feedback (LVDT)​
Brand Name Rexroth
Model Number R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M
Certification ISO
Place of Origin Germany

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union,T/T,D/P,D/A,L/C Supply Ability 100
Delivery Time 2 weeks Packaging Details wooden box
Rated Flow​ 200 L/min​ (at Δp = 10 bar per control land) Max. Flow​ Approx. 460 L/min​
Supply Voltage​ 24V DC​ (18...35 VDC) Control Signal​ ±10 V DC​ (Analog voltage input, /A1​ suffix)
Feedback​ Electrical spool position feedback (LVDT)​ Brand Name Rexroth
Model Number R900727361 4WRKE16E-200L-3X/6EG24EK31/A1D3M Certification ISO
Place of Origin Germany
High Light Rexroth proportional directional control valveRexroth hydraulic valve with warrantyPilot operated hydraulic control valve

Parameter

Specification

Order Number

R900727361

Model

4WRKE16E-200L-3X/6EG24EK31/A1D3M

Type

Pilot-operated, 2-stage proportional directional valve

Function

4/3-way (3 positions, 4 ports), spring-centered

Spool Type

E (Linear characteristic, with electrical position feedback)

Nominal Size

NG16​ (CETOP 7)

Max. Operating Pressure

P, A, B: 350 bar

Rated Flow

200 L/min​ (at Δp = 10 bar per control land)

Max. Flow

Approx. 460 L/min

Electronics

Integrated On-Board Electronics (OBE)

Supply Voltage

24V DC​ (18...35 VDC)

Control Signal

±10 V DC​ (Analog voltage input, /A1​ suffix)

Feedback

Electrical spool position feedback (LVDT)

Pilot Oil Supply

External (X)

Pilot Oil Return

External (Y)

Manual Override

No

Pressure Reducing Valve

Yes (D3, ZDR 6 DP0-4X/40YM)

Seal Material

NBR (M)

Electrical Connector

7-pin plug (DIN EN 175201-804, K31)

Mounting Interface

ISO 4401-07-07-0-05 (CETOP 7 subplate)

Suitable Media

Mineral oils (HL, HLP), HETG, HEES, HEPG, HFDU, HFDR

Media Temperature

-20°C to +80°C​ (optimal 40–50°C)

Viscosity Range

20 to 380 mm²/s

Weight

Approx. 11.2 kg

4WRZE16E1-150-72/6EG24EK31/A1M
4WRZE16E1-150-72/6EG24ETK31/A1D3M
4WRZE16E1-150-72/6EG24ETK31/A1M
4WRZE16E1-150-72/6EG24K31/A1M
4WRZE16E1-150-72/6EG24N9EK31/A1D3M
4WRZE16E1-150-72/6EG24N9EK31/A1D3V
4WRZE16E1-150-72/6EG24N9EK31/A1M
4WRZE16E1-150-72/6EG24N9ETK31/A1D3V
4WRZE16E1-150-72/6EG24N9K31/A1D3M
4WRZE16E1-150-72/6EG24N9K31/A1M
4WRZE16E1-150-72/6EG24N9K31/A1V
4WRZE16E1-150-72/6EG24NJEK31/F1D3M
4WRZE16E150-72/6EG24EK31/A1D3M
4WRZE16E150-72/6EG24EK31/A1V
4WRZE16E150-72/6EG24ETK31/A1D3M
4WRZE16E150-72/6EG24ETK31/A1D3V
4WRZE16E150-72/6EG24ETK31/A1M
4WRZE16E150-72/6EG24K31/A1D3M
4WRZE16E150-72/6EG24K31/A1M
4WRZE16E150-72/6EG24N9EK31/A1D3M
4WRZE16E150-72/6EG24N9EK31/A1D3V
4WRZE16E150-72/6EG24N9EK31/A1M
4WRZE16E150-72/6EG24N9EK31/F1D3M
4WRZE16E150-72/6EG24N9ETK31/A1D3M
4WRZE16E150-72/6EG24N9ETK31/A1D3V
4WRZE16E150-72/6EG24N9ETK31/A1V
4WRZE16E150-72/6EG24N9K31/A1D3M
4WRZE16E150-72/6EG24N9K31/A1D3V
4WRZE16E150-72/6EG24N9K31/A1M
4WRZE16E150-72/6EG24N9K31/A1V
4WRZE16E150-72/6EG24TK31/A1M
4WRZE16E3-150-72/6EG24EK31/A1D3M
4WRZE16E3-150-72/6EG24N9TK31/A1M
4WRZE16EA150-72/6EG24ETK31/A1M
4WRZE16EA150-72/6EG24K31/A1D3M
4WRZE16EA150-72/6EG24K31/A1M
4WRZE16EA150-72/6EG24K31/F1V
4WRZE16EA150-72/6EG24N9ETK31/A1D3M
4WRZE16EB150-72/6EG24EK31/A1D3V
4WRZE16W6 150-72/6EG24K31/A1M
4WRZE16W6-100-72/6EG24ETK31/A1D3M
4WRZE16W6-100-72/6EG24ETK31/A1D3V
4WRZE16W6-100-72/6EG24ETK31/F1D3V
4WRZE16W6-100-72/6EG24K31/A1M
4WRZE16W6-100-72/6EG24K31/F1D3M
4WRZE16W6-100-72/6EG24N9ETK31/A1D3M
4WRZE16W6-100-72/6EG24N9ETK31/A1M
4WRZE16W6-100-72/6EG24N9ETK31/F1D3M
4WRZE16W6-100-72/6EG24N9ETK31/F1D3V
4WRZE16W6-100-72/6EG24N9K31/A1M
4WRZE16W6-100-72/6EG24N9K31/F1D3M
4WRZE16W6-100-72/6EG24N9K31/F1V
4WRZE16W6-100-72/6EG24N9TK31/F1D3M
4WRZE16W6-150-72/6EG24EK31/A1D3M
4WRZE16W6-150-72/6EG24EK31/A1M
4WRZE16W6-150-72/6EG24EK31/A1V
4WRZE16W6-150-72/6EG24EK31/F1D3M
4WRZE16W6-150-72/6EG24ETK31/A1D3M
4WRZE16W6-150-72/6EG24ETK31/A1M
4WRZE16W6-150-72/6EG24ETK31/F1D3M
4WRZE16W6-150-72/6EG24K31/A1D3M
4WRZE16W6-150-72/6EG24K31/A1V
4WRZE16W6-150-72/6EG24K31/F1D3M
4WRZE16W6-150-72/6EG24N9EK31/A1D3M
4WRZE16W6-150-72/6EG24N9EK31/A1M
4WRZE16W6-150-72/6EG24N9EK31/A1V
4WRZE16W6-150-72/6EG24N9EK31/F1D3M
4WRZE16W6-150-72/6EG24N9EK31/F1D3V
4WRZE16W6-150-72/6EG24N9EK31/F1V
4WRZE16W6-150-72/6EG24N9ETK31/A1D3M
4WRZE16W6-150-72/6EG24N9ETK31/A1D3V

FAQ:

  1. Pilot Oil Configuration (/6EG24EK31)

    This valve uses external pilot oil supply (X port) and external pilot oil return (Y port). You must provide clean, filtered pilot oil to the X port (25–315 bar) and ensure the Y port drains directly to the tank with minimal backpressure (max 10 bar).

  2. Control Signal (/A1)

    The /A1​ suffix indicates a ±10 V voltage input. This is ideal for high-precision control systems (e.g., servo controllers) where fine resolution and fast signal response are required.

  3. Integrated Pressure Reducing Valve (/D3)

    The /D3​ option includes an integrated ZDR 6​ pressure reducing valve. It ensures the pilot stage receives a stable, reduced pressure (typically around 40 bar), protecting the sensitive pilot valve from high and fluctuating main system pressures.

  4. Critical Installation Notes

    • Drain Line:​ The external pilot drain (Y port) must be connected directly to the tank with a dedicated line. Backpressure on Y must be < 10 bar.

    • Cleanliness:​ Maintain high oil cleanliness (recommended NAS 1638 Class 8 or ISO 4406 20/18/15 for the main stage).

    • Pilot Supply:​ Provide clean, regulated pilot pressure to the X port.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Total Annual:

    1 million-10 millon

  • Employee Number:

    >50

  • Ecer Certification:

    Verified Supplier

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...

+ Read More

Get in touch with us

  • Reach Us
  • Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
  • Nan'an, Fujian Province, China
  • https://www.electrichydpump.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement