Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
{"title":"German Rexroth Industrial Hydraulic Piston Pump with 12 Months Warranty 100%","imgUrl":"https:\/\/img.chinax.com\/nimg\/c5\/22\/7b29d922c10b11ac94ce0beec2ac-200x200-1\/german_rexroth_industrial_hydraulic_piston_pump_with_12_months_warranty_100_25_tested_great_performance_and_threaded_or_flanged_in.jpg","attrs":{"Brand Name":"Rexroth","Model Number":"A2FO90\/61R-PAB05 A2FO90\/61L-PAB05 A2FO90\/61R-PBB05 A2FO90\/61R-VBB05 A2FO90\/61R-VQDN55","Certification":"ISO","Place of Origin":"German"}}
{"title":"A4VSO71EO1\/30L-PPB13N00 A4VSO71LR2\/30L-PPB25N00 German piston bar axial","imgUrl":"https:\/\/img.chinax.com\/nimg\/35\/dd\/d32d0532f1879d4c55968ff91d80-200x200-1\/a4vso71eo1_2f30l_ppb13n00_a4vso71lr2_2f30l_ppb25n00_german_piston_bar_axial_excavator_motor_rexroth_brand_new_original_warranty_fo.jpg","attrs":{"Brand Name":"Rexroth","Model Number":"A4VSO71EO1\/30L-PPB13N00 A4VSO71LR2\/30L-PPB25N00","Certification":"ISO9001","Place of Origin":"German"}}
{"title":"German Rexroth ISO9001 Certified Piston Pump for Mobile and Industrial Hydraulic","imgUrl":"https:\/\/img.chinax.com\/nimg\/73\/0e\/c4fe575b539956cb89a167a3ff3d-200x200-1\/german_rexroth_iso9001_certified_piston_pump_for_mobile_and_industrial_hydraulic_systems_with_clockwise_or_counterclockwise_rotati.jpg","attrs":{"Brand Name":"Rexroth","Model Number":"A2FO107\/61R-NBD55 A2FO107\/61R-PPB05 A2FO107\/61R-VPB05 A2FO107\/61R-VSD55 A2FO107\/61L-VSD55","Certification":"ISO","Place of Origin":"German"}}
DFR is a combined pressure-flow control with load sensing (LS).
Pressure Control: Limits system pressure to a set maximum (like a relief valve).
Flow Control (LS): The pump automatically adjusts its swashplate angle to deliver only the flow required by the actuators, maintaining a constant pressure differential (Δp) across the control orifice. This results in significant energy savings compared to constant flow pumps.
Can I mount an additional pump on the back?
No. The code N00 in VPA12N00 explicitly indicates no through-drive. The shaft does not extend through the rear cover, so you cannot mount a second pump (gear or piston) on the back of this unit. If you need a tandem pump configuration, you must order a variant with a through-drive code (e.g., ending in K...).
What are the critical installation precautions?
Case Drain (L ports): This pump has two case drain ports. They must be connected separately to tank with minimal backpressure (max 2-3 bar). Do not tee them into the main return line. This is critical for flushing heat and preventing seal/bearing failure.
Suction Conditions: Ensure inlet pressure at port S is ≥ -0.8 bar (absolute) to avoid cavitation. Use short, large-diameter suction lines.
Rotation: Confirm motor rotation matches the pump's "R" (clockwise) designation. Running backwards can destroy the pump.
Why is my pump noisy or overheating?
Noise: Usually caused by cavitation. Check suction filter, inlet line for leaks, or oil viscosity being too high at startup.
Overheating: Often due to excessive case pressure (blocked or undersized case drain line) or operating for long periods at high pressure with small displacement (high power loss).
How do I adjust the pressure and flow settings?
The DFR control has two adjustment screws (usually under caps on the control housing):
Pressure Limiter: Sets the maximum system pressure (clockwise to increase).
Flow Controller (LS Δp): Sets the pressure differential for load sensing (typically set to 10-20 bar).
Always adjust under controlled conditions with a pressure gauge.
Is an external relief valve still needed?
Yes. While the DFR control limits pressure, it is not a safety valve. You must install a separate system relief valve (e.g., a DB/DBW type) in the main line as a safety backup against control failure.
What is the difference between DFR and DRS?
DFR: Typically used in industrial applications with explicit pressure/flow control.
DRS: Often used in mobile applications with a stronger emphasis on load sensing. The functional principle is very similar, but the control response and internal pilot circuitry may differ.
Disclaimer: For precise installation and commissioning, always refer to the official Rexroth technical data sheet RE 25700 for A10VSO Series 31 pumps.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...