| Payment Terms | Western Union,T/T,D/P,D/A,L/C |
| Delivery Time | 2 weeks |
| Solenoid Voltage | 24 V DC (G24) |
| Supply Ability | 100 |
| Max. Operating Pressure (P-port) | 350 bar |
| Packaging Details | wooden box |
| Max. Flow Rate (Qmax) | approx. 250 L/min (Size 10 DB/DBW series) |
| Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Body Material | Cast iron / steel, zinc-plated |
| Certification | ISO |
| Place of Origin | German |
| Model Number | R900924381 DBW10B1-5X/350-6EG24N9K4 |
| Brand Name | German |
View Detail Information
Explore similar products
R901411433 4WRPEH10C4B100L-3X/M/24A1 German Rexroth hydraulic proportional valve
R900549534 4WE6HA6X/EG24N9K4 Rexroth electromagnetic directional valve
R901507310 4WRPEH10C3B100L-3X/M/24F1 Proportional directional valve from Rexroth
R900553670 4WE6HB6X/EG24N9K4 Hydraulic directional valve solenoid valve Rexroth
Product Specification
| Payment Terms | Western Union,T/T,D/P,D/A,L/C | Delivery Time | 2 weeks |
| Solenoid Voltage | 24 V DC (G24) | Supply Ability | 100 |
| Max. Operating Pressure (P-port) | 350 bar | Packaging Details | wooden box |
| Max. Flow Rate (Qmax) | approx. 250 L/min (Size 10 DB/DBW series) | Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Body Material | Cast iron / steel, zinc-plated | Certification | ISO |
| Place of Origin | German | Model Number | R900924381 DBW10B1-5X/350-6EG24N9K4 |
| Brand Name | German | ||
| High Light | Rexroth hydraulic overflow valve ,German made electromagnetic valve ,DBW10B1-5X hydraulic valve | ||
|
Parameter |
Value |
|---|---|
|
Part Number |
R900924381 |
|
Model |
DBW 10 - B1 - 5X / 350 - 6EG24N9K4 |
|
Valve Type |
Pilot-operated pressure relief valve with integrated solenoid unloading (DBW series) |
|
Nominal Size (NG) |
10 — subplate mounting per ISO 6264 / NG10 |
|
Function |
Pressure limiting at set value + solenoid-actuated system unloading (energize → P→T open, system near 0 bar) |
|
Adjustment Type |
B1 = Hexagon socket setscrew with protective cap (Allen key adjustable; B-version has different pilot damping orifice vs A1) |
|
Component Series |
5X (series 50–59, dimensionally interchangeable) |
|
Max. Adjustable Relief Pressure |
350 bar (adjustment range typically 5–350 bar) |
|
Max. Operating Pressure (P-port) |
350 bar |
|
Max. Flow Rate (Qmax) |
approx. 250 L/min (Size 10 DB/DBW series) |
|
Pilot Oil |
Internal pilot supply, internal pilot drain (standard DBW) |
|
Solenoid Type |
Wet-pin DC solenoid |
|
Solenoid Voltage |
24 V DC (G24) |
|
Electrical Connection |
Plug-in socket per EN 175301-803 Form A (K4 = mating plug sold separately) |
|
Manual Override |
N9 = concealed push-button manual override on coil |
|
Seal Material |
NBR (standard, for mineral oil HL/HLP, HFC) |
|
Hydraulic Fluid |
Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD |
|
Fluid Temperature Range |
-30 °C to +80 °C (NBR seals) |
|
Viscosity Range |
10–800 mm²/s |
|
Weight (approx.) |
3.2 kg |
|
Body Material |
Cast iron / steel, zinc-plated |
![]()
| R900020154 VT3002-1-2X/48F |
| 0811405106 VT-MSPA2-525-1X/V0 |
| 0811405061 VT-VRRA1-537-2X/V0 |
| 0811405063 VT-VRRA1-527-2X/V0/2STV |
| R901057058 VT-VRPA1-150-1X/V0/0 |
| R901439036 VT-MSPA1-2X/F5/000/000 |
| R901439037 VT-MSPA2-2X/A5/000/000 |
| R901439038 VT-MSPA2-2X/F5/000/000 |
| R900579497 VT-5035-1X |
| 0811405140 VT-MACAS-500-1X/V0/I |
| R900217318 VT-SWMAK-1-1X/V0/0 |
| R901049737 VT-VETSY-1-1X/1-2-1-1-0/ |
| 0811405119 VT-VRPA2-527-10/V0/RTP |
| R900214081 VT-VSPA2-50-10/T1 |
| R900952202 VT-VRPA1-50-1X |
| R900703811 VT-DFP-A-2X/G24K0/0/V |
| R900913443 4WRA6W15-2X/G24N9K4/V |
| R900902095 4WRA6W30-2X/G24N9K4/V |
| R900902537 4WRA6W1-30-2X/G24N9K4/V |
| R901015613 4WRAE6E30-2X/G24K31/F1V |
| R900974817 4WRAE6W1-30-2X/G24K31/F1V |
| R901036556 4WRE6V16-2X/G24K4/V-822 |
| R901496427 4WREE6E16-3X/V/24A1 |
| R901496443 4WREE6E16-3X/V/24F1 |
| R901496435 4WREE6E32-3X/V/24F1 |
| R901496448 4WREE6E1-32-3X/V/24F1 |
| R901496437 4WREE6W16-3X/V/24A1 |
| R901523727 4WREE6W16-3X/V/24F1 |
| R901496451 4WREE6W1-16-3X/V/24F1 |
| R901496438 4WREE6W32-3X/V/24F1 |
| R901496432 4WREE6W32-3X/V/24A1 |
| R901496441 4WREE6W1-32-3X/V/24F1 |
| R901517458 4WREE6V1-32-3X/M/24F1 |
| R900954064 4WRA10EA60-2X/G24K4/V |
| R900902097 4WRA10E60-2X/G24N9K4/V |
| R900907650 4WRA10W60-2X/G24N9K4/V |
| R900954083 4WRAE10E60-2X/G24K31/A1V |
| R900965674 4WRAE10E60-2X/G24K31/F1V |
| R900954089 4WRAE10W1-60-2X/G24K31/A1V |
| R900949757 4WRAE10W1-60-2X/G24N9K31/F1V |
| R900927231 4WREE10E50-2X/G24K31/A1V |
| R900927230 4WREE10E75-2X/G24K31/A1V |
| R900949806 4WREE10W50-2X/G24K31/F1V |
| R900927233 4WREE10W75-2X/G24K31/A1V |
| R900948360 4WREE10W75-2X/G24K31/F1V |
| R900962405 4WREE10W1-25-2X/G24K31/F1V |
| R900965185 4WREE10W1-50-2X/G24K31/F1V |
| R900927234 4WREE10W1-75-2X/G24K31/A1V |
| R900976119 4WREE10W1-75-2X/G24K31/F1V |
| R900924607 4WREE10V75-2X/G24K31/A1V |
| R900617269 4WREE10V75-2X/G24K31/F1V |
| R900617676 4WRZE10E85-7X/6EG24N9ETK31/A1D3M |
| R900751838 4WRZE10W6-50-7X/6EG24N9EK31/F1D3M |
| R900765029 4WRZE10W6-85-7X/6EG24N9ETK31/A1D3M |
| R901188943 4WRZE16E-150-7X/6EG24N9EK31/A1D3M |
| R900765378 4WRZE16E1-150-7X/6EG24N9K31/A1M |
| R900753984 4WRZE16E1-150-7X/6EG24N9ETK31/F1M |
| R900953885 4WRZ16W6-150-7X/6EG24N9K4/D3V |
| R900727999 4WRZE16W6-150-7X/6EG24N9ETK31/F1D3M |
| R900700633 4WRZE16W8-150-7X/6EG24N9ETK31/A1D3M |
| R901051825 4WRZE16W8-150-7X/6EG24N9K31/F1D3M |
| R900757605 4WRZE16W8-150-7X/6EG24N9EK31/F1D3M |
| R900721116 4WRZE16W8-150-7X/6EG24N9ETK31/F1D3M |
| R900958570 4WRZ25W6-325-7X/6EG24N9K4/D3M |
| R900244765 4WRZ25W6-325-7X/6EG24N9ETK4/D3M |
| R901072891 4WRZE25W6-325-7X/6EG24N9K31/F1D3M |
Q1: What is the difference between A1 and B1 versions (DBW10A1 vs DBW10B1)?
Both are subplate-mounted pilot relief valves with solenoid unload and identical adjustment method (hex socket + cap). The B1 version has a different pilot-stage damping orifice — it provides slightly different dynamic response (pressure overshoot/settling) vs A1. Pressure range, flow rating, solenoid, and mounting are identical. A1 is the general-purpose default; B1 is selected when system stability/damping tuning is required.
Q2: Is this direct-acting or pilot-operated?
It is a pilot-operated (two-stage) relief valve with solenoid unloading. A pilot stage controls the main spool for stable high-flow relief; the integrated solenoid can command the valve to dump system pressure to tank.
Q3: How do I adjust the relief pressure?
With system depressurized, remove the protective cap, turn the setscrew with an Allen key — clockwise to increase, counterclockwise to decrease. Factory preset is typically near minimum of the spring range. Reinstall cap and verify with a pressure gauge. The solenoid does NOT change the set pressure.
Q4: What is the solenoid logic?
Standard: Solenoid DE-energized = relief active at set pressure. Solenoid ENERGIZED = system unloaded (P connected to T, near tank pressure). Confirm this matches your control logic before wiring.
Q5: Which subplate and electrical connector are needed?
Subplate: standard NG10 (ISO 6264) with P and T ports (G 1/2" or M18×1.5 on subplate), four M10 bolts @ ~35–40 N·m.
Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (–) polarity markings.
Q6: Common faults & causes?
Solenoid clicks but system does NOT unload: pilot orifice clogged, main spool stuck, no coil current (check ~18–28 Ω), manual override jammed.
Pressure won't reach set value / creeps early: wrong spring (not /350), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain).
Coil overheats / burnt smell: overvoltage (>10% above 24V), wrong voltage coil fitted, or mechanical damage — replace only with correct G24 wet-pin coil.
Chatter / unstable: air in system, high T-backpressure, worn pilot seat — bleed air first.
Q7: Does T-port backpressure affect set pressure?
Yes — this model has internal pilot drain. Backpressure at T adds 1:1 to the relief setpoint. If your tank line has >5 bar sustained backpressure, consider the DBW…Y version (external pilot drain to separate tank line).
Q8: Fluid & seal compatibility?
NBR seals = mineral oil (HL/HLP) & HFC (water-glycol). For HEES/HETG biodegradable oils or HFD phosphate ester → specify FKM (Viton) seal variant. Maintain oil cleanliness per ISO 4406 code 18/16/13 or better.
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...
Get in touch with us
Leave a Message, we will call you back quickly!