China factories

Chat Now Send Email
China factory - Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.

  • China ,Fujian
  • Verified Supplier
  1. Home
  2. Products
  3. About Us
  4. Contact Us

Leave a Message

we will call you back quickly!

Submit Requirement
China R900924381 DBW10B1-5X/350-6EG24N9K4 German made original electromagnetic
China R900924381 DBW10B1-5X/350-6EG24N9K4 German made original electromagnetic

  1. China R900924381 DBW10B1-5X/350-6EG24N9K4 German made original electromagnetic

R900924381 DBW10B1-5X/350-6EG24N9K4 German made original electromagnetic

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Payment Terms Western Union,T/T,D/P,D/A,L/C
Delivery Time 2 weeks
Solenoid Voltage 24 V DC (G24)
Supply Ability 100
Max. Operating Pressure (P-port) 350 bar
Packaging Details wooden box
Max. Flow Rate (Qmax) approx. 250 L/min (Size 10 DB/DBW series)
Fluid Temperature Range -30 °C to +80 °C (NBR seals)
Body Material Cast iron / steel, zinc-plated
Certification ISO
Place of Origin German
Model Number R900924381 DBW10B1-5X/350-6EG24N9K4
Brand Name German

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union,T/T,D/P,D/A,L/C Delivery Time 2 weeks
Solenoid Voltage 24 V DC (G24) Supply Ability 100
Max. Operating Pressure (P-port) 350 bar Packaging Details wooden box
Max. Flow Rate (Qmax) approx. 250 L/min (Size 10 DB/DBW series) Fluid Temperature Range -30 °C to +80 °C (NBR seals)
Body Material Cast iron / steel, zinc-plated Certification ISO
Place of Origin German Model Number R900924381 DBW10B1-5X/350-6EG24N9K4
Brand Name German
High Light Rexroth hydraulic overflow valveGerman made electromagnetic valveDBW10B1-5X hydraulic valve

Rexroth DBW10B1-5X/350-6EG24N9K4 — Pilot-Operated Solenoid Relief Valve (P/N: R900924381)

Technical Data / Specifications

Parameter

Value

Part Number

R900924381

Model

DBW 10 - B1 - 5X / 350 - 6EG24N9K4

Valve Type

Pilot-operated pressure relief valve with integrated solenoid unloading (DBW series)

Nominal Size (NG)

10 — subplate mounting per ISO 6264 / NG10

Function

Pressure limiting at set value + solenoid-actuated system unloading​ (energize → P→T open, system near 0 bar)

Adjustment Type

B1 = Hexagon socket setscrew with protective cap (Allen key adjustable; B-version has different pilot damping orifice vs A1)

Component Series

5X (series 50–59, dimensionally interchangeable)

Max. Adjustable Relief Pressure

350 bar (adjustment range typically 5–350 bar)

Max. Operating Pressure (P-port)

350 bar

Max. Flow Rate (Qmax)

approx. 250 L/min (Size 10 DB/DBW series)

Pilot Oil

Internal pilot supply, internal pilot drain (standard DBW)

Solenoid Type

Wet-pin DC solenoid

Solenoid Voltage

24 V DC (G24)

Electrical Connection

Plug-in socket per EN 175301-803 Form A (K4 = mating plug sold separately)

Manual Override

N9 = concealed push-button manual override on coil

Seal Material

NBR (standard, for mineral oil HL/HLP, HFC)

Hydraulic Fluid

Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD

Fluid Temperature Range

-30 °C to +80 °C (NBR seals)

Viscosity Range

10–800 mm²/s

Weight (approx.)

3.2 kg

Body Material

Cast iron / steel, zinc-plated

R900020154  VT3002-1-2X/48F
0811405106  VT-MSPA2-525-1X/V0
0811405061  VT-VRRA1-537-2X/V0
0811405063  VT-VRRA1-527-2X/V0/2STV
R901057058  VT-VRPA1-150-1X/V0/0
R901439036  VT-MSPA1-2X/F5/000/000
R901439037  VT-MSPA2-2X/A5/000/000
R901439038  VT-MSPA2-2X/F5/000/000
R900579497  VT-5035-1X
0811405140  VT-MACAS-500-1X/V0/I
R900217318  VT-SWMAK-1-1X/V0/0
R901049737  VT-VETSY-1-1X/1-2-1-1-0/
0811405119  VT-VRPA2-527-10/V0/RTP
R900214081  VT-VSPA2-50-10/T1
R900952202  VT-VRPA1-50-1X
R900703811  VT-DFP-A-2X/G24K0/0/V
R900913443   4WRA6W15-2X/G24N9K4/V
R900902095   4WRA6W30-2X/G24N9K4/V
R900902537  4WRA6W1-30-2X/G24N9K4/V
R901015613   4WRAE6E30-2X/G24K31/F1V
R900974817   4WRAE6W1-30-2X/G24K31/F1V
R901036556   4WRE6V16-2X/G24K4/V-822
R901496427   4WREE6E16-3X/V/24A1
R901496443   4WREE6E16-3X/V/24F1
R901496435  4WREE6E32-3X/V/24F1
R901496448   4WREE6E1-32-3X/V/24F1
R901496437   4WREE6W16-3X/V/24A1
R901523727   4WREE6W16-3X/V/24F1
R901496451   4WREE6W1-16-3X/V/24F1
R901496438   4WREE6W32-3X/V/24F1
R901496432   4WREE6W32-3X/V/24A1
R901496441  4WREE6W1-32-3X/V/24F1
R901517458   4WREE6V1-32-3X/M/24F1 
R900954064   4WRA10EA60-2X/G24K4/V 
R900902097   4WRA10E60-2X/G24N9K4/V
R900907650   4WRA10W60-2X/G24N9K4/V
R900954083   4WRAE10E60-2X/G24K31/A1V
R900965674   4WRAE10E60-2X/G24K31/F1V
R900954089   4WRAE10W1-60-2X/G24K31/A1V
R900949757   4WRAE10W1-60-2X/G24N9K31/F1V
R900927231   4WREE10E50-2X/G24K31/A1V
R900927230   4WREE10E75-2X/G24K31/A1V
R900949806   4WREE10W50-2X/G24K31/F1V
R900927233   4WREE10W75-2X/G24K31/A1V
R900948360   4WREE10W75-2X/G24K31/F1V
R900962405   4WREE10W1-25-2X/G24K31/F1V
R900965185   4WREE10W1-50-2X/G24K31/F1V
R900927234   4WREE10W1-75-2X/G24K31/A1V
R900976119   4WREE10W1-75-2X/G24K31/F1V
R900924607   4WREE10V75-2X/G24K31/A1V
R900617269   4WREE10V75-2X/G24K31/F1V
R900617676 4WRZE10E85-7X/6EG24N9ETK31/A1D3M
R900751838 4WRZE10W6-50-7X/6EG24N9EK31/F1D3M
R900765029 4WRZE10W6-85-7X/6EG24N9ETK31/A1D3M
R901188943 4WRZE16E-150-7X/6EG24N9EK31/A1D3M
R900765378 4WRZE16E1-150-7X/6EG24N9K31/A1M
R900753984 4WRZE16E1-150-7X/6EG24N9ETK31/F1M
R900953885  4WRZ16W6-150-7X/6EG24N9K4/D3V 
R900727999 4WRZE16W6-150-7X/6EG24N9ETK31/F1D3M
R900700633 4WRZE16W8-150-7X/6EG24N9ETK31/A1D3M
R901051825 4WRZE16W8-150-7X/6EG24N9K31/F1D3M
R900757605 4WRZE16W8-150-7X/6EG24N9EK31/F1D3M
R900721116 4WRZE16W8-150-7X/6EG24N9ETK31/F1D3M
R900958570  4WRZ25W6-325-7X/6EG24N9K4/D3M
R900244765 4WRZ25W6-325-7X/6EG24N9ETK4/D3M
R901072891 4WRZE25W6-325-7X/6EG24N9K31/F1D3M

Frequently Asked Questions (FAQ)

Q1: What is the difference between A1 and B1 versions (DBW10A1 vs DBW10B1)?

Both are subplate-mounted pilot relief valves with solenoid unload and identical adjustment method (hex socket + cap). The B1 version has a different pilot-stage damping orifice​ — it provides slightly different dynamic response (pressure overshoot/settling) vs A1. Pressure range, flow rating, solenoid, and mounting are identical. A1 is the general-purpose default; B1 is selected when system stability/damping tuning is required.

Q2: Is this direct-acting or pilot-operated?

It is a pilot-operated (two-stage) relief valve with solenoid unloading. A pilot stage controls the main spool for stable high-flow relief; the integrated solenoid can command the valve to dump system pressure to tank.

Q3: How do I adjust the relief pressure?

With system depressurized, remove the protective cap, turn the setscrew with an Allen key — clockwise to increase, counterclockwise to decrease. Factory preset is typically near minimum of the spring range. Reinstall cap and verify with a pressure gauge. The solenoid does NOT change the set pressure.

Q4: What is the solenoid logic?

Standard: Solenoid DE-energized = relief active​ at set pressure. Solenoid ENERGIZED = system unloaded​ (P connected to T, near tank pressure). Confirm this matches your control logic before wiring.

Q5: Which subplate and electrical connector are needed?

  • Subplate: standard NG10 (ISO 6264)​ with P and T ports (G 1/2" or M18×1.5 on subplate), four M10 bolts @ ~35–40 N·m.

  • Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (–) polarity markings.

Q6: Common faults & causes?

  • Solenoid clicks but system does NOT unload:​ pilot orifice clogged, main spool stuck, no coil current (check ~18–28 Ω), manual override jammed.

  • Pressure won't reach set value / creeps early:​ wrong spring (not /350), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain).

  • Coil overheats / burnt smell:​ overvoltage (>10% above 24V), wrong voltage coil fitted, or mechanical damage — replace only with correct G24 wet-pin coil.

  • Chatter / unstable:​ air in system, high T-backpressure, worn pilot seat — bleed air first.

Q7: Does T-port backpressure affect set pressure?

Yes — this model has internal pilot drain. Backpressure at T adds 1:1 to the relief setpoint. If your tank line has >5 bar sustained backpressure, consider the DBW…Y version (external pilot drain to separate tank line).

Q8: Fluid & seal compatibility?

NBR seals = mineral oil (HL/HLP) & HFC (water-glycol). For HEES/HETG biodegradable oils or HFD phosphate ester → specify FKM (Viton) seal variant. Maintain oil cleanliness per ISO 4406 code 18/16/13 or better.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Total Annual:

    1 million-10 millon

  • Employee Number:

    >50

  • Ecer Certification:

    Verified Supplier

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...

+ Read More

Get in touch with us

  • Reach Us
  • Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
  • Nan'an, Fujian Province, China
  • https://www.electrichydpump.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement