| Supply Ability | 100 |
| Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Payment Terms | Western Union,D/P,T/T,D/A,L/C |
| Max. Operating Pressure (Secondary port) | 315 bar |
| Pilot Oil Drain | Y = External pilot drain (separate Y‑port to tank — isolates set pressure from T‑line backpressure) |
| Viscosity Range | 10–800 mm²/s |
| Max. Flow Rate (Qmax) | approx. 60 L/min (Size 6 ZDR) |
| Packaging Details | wooden box |
| Delivery Time | 2 weeks |
| Model Number | R900410855 ZDR6DA2-4X/210Y |
| Brand Name | Rexroth |
| Certification | ISO |
| Place of Origin | Germany |
View Detail Information
Explore similar products
R901411433 4WRPEH10C4B100L-3X/M/24A1 German Rexroth hydraulic proportional valve
R900549534 4WE6HA6X/EG24N9K4 Rexroth electromagnetic directional valve
R901507310 4WRPEH10C3B100L-3X/M/24F1 Proportional directional valve from Rexroth
R900553670 4WE6HB6X/EG24N9K4 Hydraulic directional valve solenoid valve Rexroth
Product Specification
| Supply Ability | 100 | Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Payment Terms | Western Union,D/P,T/T,D/A,L/C | Max. Operating Pressure (Secondary port) | 315 bar |
| Pilot Oil Drain | Y = External pilot drain (separate Y‑port to tank — isolates set pressure from T‑line backpressure) | Viscosity Range | 10–800 mm²/s |
| Max. Flow Rate (Qmax) | approx. 60 L/min (Size 6 ZDR) | Packaging Details | wooden box |
| Delivery Time | 2 weeks | Model Number | R900410855 ZDR6DA2-4X/210Y |
| Brand Name | Rexroth | Certification | ISO |
| Place of Origin | Germany | ||
| High Light | Rexroth hydraulic pressure valve ,R900410855 pressure valve ,ZDR6DA2-4X/210Y hydraulic valve | ||
|
Parameter |
Value |
|---|---|
|
Part Number |
R900410855 |
|
Model |
ZDR 6 - DA2 - 4X / 210Y |
|
Valve Type |
Direct-acting, 3‑way pressure reducing valve (sandwich / stackable) |
|
Nominal Size (NG) |
6 — sandwich mounting per ISO 5781 / NG6 (DIN 24340 Form E) |
|
Function |
Reduces & maintains pressure in secondary circuit to set value; 3‑way action (excess dumps via external drain) |
|
Adjustment Type |
DA2 = Rotary hand knob with protective cap (hand‑adjustable, no tool) |
|
Component Series |
4X (series 40–49, dimensionally interchangeable) |
|
Max. Adjustable Reduced Pressure |
210 bar (adj. range typically 4–210 bar) |
|
Max. Operating Pressure (Primary P‑port) |
315 bar |
|
Max. Operating Pressure (Secondary port) |
315 bar |
|
Max. Flow Rate (Qmax) |
approx. 60 L/min (Size 6 ZDR) |
|
Pilot Oil Drain |
Y = External pilot drain (separate Y‑port to tank — isolates set pressure from T‑line backpressure) |
|
Seal Material |
NBR (standard, code omitted = NBR, for mineral oil HL/HLP, HFC) |
|
Hydraulic Fluid |
Mineral oil HL, HLP per DIN 51524; HFC (water‑glycol); HLPD, HVLP, HVLPD |
|
Fluid Temperature Range |
-30 °C to +80 °C (NBR seals) |
|
Viscosity Range |
10–800 mm²/s |
|
Weight (approx.) |
1.7 kg |
|
Body Material |
Steel / cast iron, zinc‑plated |
![]()
| R910927083 A A10VSO100 DFR1/31R-PPA12K02 |
| R910983124 A A10VSO100 DFR1/31R-PPA12KB3 |
| R910984741 A A10VSO100 DFR1/31R-PPA12KB4 |
| R910985609 A A10VSO100 DFR1/31R-PPA12KB5 |
| R902403231 A A10VSO100 DFR1/31R-PPA12KB6 |
| R910922744 A A10VSO100 DFR1/31R-PPA12N00 |
| R902418759 A A10VSO100 DFR1/31R-PSA12KB4 |
| R910971805 A A10VSO100 DFR1/31R-PSA12KB6 |
| R910949826 A A10VSO100 DFR1/31R-PSA12N00 |
| R910922681 A A10VSO100 DR /31L-VPA12N00 |
| R910968839 A A10VSO100 DR /31R-PPA12K04 |
| R910916809 A A10VSO100 DR /31R-VPA12N00 |
| R910943447 A A10VSO100 DRG /31R-PPA12N00 |
| R902420121 A A10VSO100 DRG /31R-VPA12K25 |
| R910930899 A A10VSO100 DRG /31R-VPA12N00 |
| R902448357 A A10VSO100 DRG /32R-VPB12N00 |
| R902454561 A A10VSO100 DRS/32R-VPB22U99 |
| R910968510 A A10VSO140 DFLR/31L-PPB12N00 |
| R910972152 A A10VSO140 DFLR/31R-PPB12K02 |
| R910935974 A A10VSO140 DFLR/31R-PPB12N00 |
| R902429793 A A10VSO140 DFLR/31R-VPB12N00 |
| R910921188 A A10VSO140 DFR /31L-PPB12N00 |
| R910933808 A A10VSO140 DFR /31R-PPB12K02 |
| R910939165 A A10VSO140 DFR /31R-PPB12K26 |
| R902410448 A A10VSO140 DFR /31R-PPB12KB4 |
| R910997710 A A10VSO140 DFR /31R-PPB12KB5 |
| R902416467 A A10VSO140 DFR /31R-PPB12KB6 |
| R902416466 A A10VSO140 DFR /31R-PPB12KB7 |
| R910939192 A A10VSO140 DFR /31R-PPB12N00 |
| R910993952 A A10VSO140 DFR /31R-PSB12N00 |
| R910931693 A A10VSO140 DFR /31R-VPB12N00 |
| R910947401 A A10VSO140 DFR1/31R-PPB12K01 |
| R910927126 A A10VSO140 DFR1/31R-PPB12K02 |
| R902433789 A A10VSO140 DFR1/31R-PPB12K07 |
| R910983963 A A10VSO140 DFR1/31R-PPB12KB3 |
| R910983738 A A10VSO140 DFR1/31R-PPB12KB4 |
| R910990335 A A10VSO140 DFR1/31R-PPB12KB5 |
| R910988742 A A10VSO140 DFR1/31R-PPB12KB6 |
| R910921546 A A10VSO140 DFR1/31R-PPB12N00 |
| R910967783 A A10VSO140 DFR1/31R-PPB12N00 -SO516 |
| R902459592 A A10VSO140 DFR1/31R-VPB12 |
| R902465624 A A10VSO140 DFR1/31R-VPB12K07 |
| R902431114 A A10VSO140 DFR1/31R-VPB12KB3 |
| R910927737 A A10VSO140 DR /31L-PPB12N00 |
| R910942862 A A10VSO140 DR /31L-VPB12N00 |
| R910936874 A A10VSO140 DR /31R-PPB12K02 |
| R910960029 A A10VSO140 DR /31R-PPB12K24 |
| R910922983 A A10VSO140 DR /31R-PPB12N00 |
| R910934519 A A10VSO140 DRG /31R-PPB12K01 |
| R910932852 A A10VSO140 DRG /31R-PPB12N00 |
| R902465472 A A10VSO140 DRS /32R-VPB22U99 |
| R910961074 A A10VSO140 FHD /31R-PPB12N00 |
Q1: Is ZDR a relief valve / overflow valve?
No. A relief valve (DB/DBD) limits upstream/system pressure; a pressure reducing valve (ZDR) maintains a lower, constantpressure in a downstream (secondary) circuit. If inlet (primary) pressure drops below the set reduced pressure, the ZDR opens fully and passes flow unregulated — it does not limit pump pressure.
Q2: What does "DA2 /210Y" mean?
DA2 = NG6 sandwich, rotary hand knob with protective cap (hand‑adjustable).
/210 = spring stage, max. adjustable reduced pressure = 210 bar (medium stage; /75 low, /150 low‑med, /315 high).
Y = external pilot drain — pilot oil returns via separate Y‑port to tank, not via the sandwich T‑channel.
Q3: How do I adjust the reduced pressure?
With the secondary circuit under flow, lift/remove the cap and turn the rotary knob clockwise to increase, counterclockwise to decrease. Verify with a pressure gauge at the secondary port — the knob has no calibrated scale. Factory preset is typically near minimum; always fine‑tune under operating flow if possible.
Q4: How is the valve mounted?
As a sandwich (stackable) valve between a directional control valve and the NG6 subplate. Uses NG6 DIN 24340 Form E / ISO 5781 bolt pattern. Sandwich port IDs: P = primary (high pressure from pump / P‑port of subplate), A (or B) = reduced secondary pressure to actuator, T = tank return, Y = external pilot drain to tank (must be plumbed!).
Q5: Why specify the "Y" (external drain) version?
If the T‑line in the valve stack has >2–3 bar backpressure, an internally drained ZDR's set reduced pressure will increase by the amount of T‑backpressure. The Y‑version drains the pilot independently to tank, keeping the set reduced pressure stable. Always use Y‑version if T‑backpressure is present or uncertain.
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...
Get in touch with us
Leave a Message, we will call you back quickly!