| Delivery Time | 2 weeks |
| Supply Ability | 100 |
| Solenoid Voltage | 24 V DC (G24) |
| Viscosity Range | 10–800 mm²/s |
| Packaging Details | wooden box |
| Payment Terms | Western Union,T/T,D/P,D/A,L/C |
| Max. Adjustable Relief Pressure | 200 bar (adjustment range typically 4–200 bar) |
| Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Max. Operating Pressure (P-port) | 350 bar |
| Place of Origin | German |
| Brand Name | Rexroth |
| Certification | ISO |
| Model Number | R900923103 DBW10B1-5X/200-6EG24N9K4 |
View Detail Information
Explore similar products
R901411433 4WRPEH10C4B100L-3X/M/24A1 German Rexroth hydraulic proportional valve
R900549534 4WE6HA6X/EG24N9K4 Rexroth electromagnetic directional valve
R901507310 4WRPEH10C3B100L-3X/M/24F1 Proportional directional valve from Rexroth
R900553670 4WE6HB6X/EG24N9K4 Hydraulic directional valve solenoid valve Rexroth
Product Specification
| Delivery Time | 2 weeks | Supply Ability | 100 |
| Solenoid Voltage | 24 V DC (G24) | Viscosity Range | 10–800 mm²/s |
| Packaging Details | wooden box | Payment Terms | Western Union,T/T,D/P,D/A,L/C |
| Max. Adjustable Relief Pressure | 200 bar (adjustment range typically 4–200 bar) | Fluid Temperature Range | -30 °C to +80 °C (NBR seals) |
| Max. Operating Pressure (P-port) | 350 bar | Place of Origin | German |
| Brand Name | Rexroth | Certification | ISO |
| Model Number | R900923103 DBW10B1-5X/200-6EG24N9K4 | ||
| High Light | Rexroth hydraulic overflow valve ,Rexroth electromagnetic valve 6EG24N9K4 ,DBW10B1-5X hydraulic valve with warranty | ||
|
Parameter |
Value |
|---|---|
|
Part Number |
R900923103 |
|
Model |
DBW 10 - B1 - 5X / 200 - 6EG24N9K4 |
|
Valve Type |
Pilot-operated pressure relief valve with integrated solenoid unloading (DBW series) |
|
Nominal Size (NG) |
10 — subplate mounting per ISO 6264 / NG10 |
|
Function |
Pressure limiting at set value + solenoid-actuated system unloading (energize → P→T open, system near 0 bar) |
|
Adjustment Type |
B1 = Hexagon socket with protective cap (Allen key adjustable — same adjustment style as A1, different internal throttling orifice for damping characteristics) |
|
Component Series |
5X (series 50–59, dimensionally interchangeable) |
|
Max. Adjustable Relief Pressure |
200 bar (adjustment range typically 4–200 bar) |
|
Max. Operating Pressure (P-port) |
350 bar |
|
Max. Flow Rate (Qmax) |
approx. 250 L/min (Size 10 DB/DBW series) |
|
Pilot Oil |
Internal pilot supply, internal pilot drain (standard DBW) |
|
Solenoid Type |
Wet-pin DC solenoid |
|
Solenoid Voltage |
24 V DC (G24) |
|
Electrical Connection |
Plug-in socket per EN 175301-803 Form A (K4 = mating plug sold separately) |
|
Manual Override |
N9 = concealed push-button manual override on coil |
|
Seal Material |
NBR (standard, for mineral oil HL/HLP, HFC) |
|
Hydraulic Fluid |
Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD |
|
Fluid Temperature Range |
-30 °C to +80 °C (NBR seals) |
|
Viscosity Range |
10–800 mm²/s |
|
Weight (approx.) |
3.15 kg |
|
Body Material |
Cast iron / steel, zinc-plated |
![]()
| R900955032 DBW10A1-5X/50-6EG24N9K4 |
| R901080866 DBW10A1-5X/50-6EW230N9K4 |
| R901075331 DBW10A1-5X/100-6EG24N9K4 |
| R900778046 DBW10A1-5X/100-6EW230N9K4 |
| R900936408 DBW10A1-5X/100S6EG24N9K4R12 |
| R900768339 DBW10A1-5X/100S6EW230N9K4R12 |
| R900978199 DBW10A1-5X/100U6EG24N9K4 |
| R900731691 DBW10A1-5X/100XYU6EG24N9K4 |
| R900941174 DBW10A1-5X/200-6EG24N9K4 |
| R901014775 DBW10A1-5X/200-6EW230N9K4 |
| R900775538 DBW10A1-5X/200U6EW230N9K4 |
| R900965477 DBW10A1-5X/315-6EG24N9K4 |
| R900969379 DBW10A1-5X/315-6EW230N9K4 |
| R901220053 DBW10A1-5X/315S6EG24N9K4R12 |
| R901019708 DBW10A1-5X/315U6EG24N9K4 |
| R901206203 DBW10A1-5X/315U6EW230N9K4 |
| R901076401 DBW10A1-5X/315Y6EG24N9K4 |
| R900770685 DBW10A1-5X/350-6EG24N9K4 |
| R901081986 DBW10A1-5X/350S6EG24N9K4R12 |
| R900731666 DBW10A2-5X/50-6EG24N9K4 |
| R900709700 DBW10A2-5X/50S6EG24N9K4R12 |
| R900618742 DBW10A2-5X/50YS6EG24N9K4R12 |
| R900966799 DBW10A2-5X/50XY6EW230N9K4 |
| R900948450 DBW10A2-5X/100-6EG24N9K4 |
| R900919570 DBW10A2-5X/100-6EW230N9K4 |
| R900952229 DBW10A2-5X/100U6EG24N9K4 |
| R900744546 DBW10A2-5X/100U6EW230N9K4 |
| R900936176 DBW10A2-5X/100U6EW230N9K4V |
| R900967954 DBW10A2-5X/100X6EG24N9K4 |
| R900778745 DBW10A2-5X/100Y6EG24N9K4 |
| R900714015 DBW10A2-5X/100YU6EG24N9K4 |
| R900955622 DBW10A2-5X/200-6EG24NK4 |
| R900926249 DBW10A2-5X/200-6EG24N9K4 |
| R900934197 DBW10A2-5X/200-6EG24N9K4V |
| R900708837 DBW10A2-5X/200-6EW230N9K4 |
| R900618747 DBW10A2-5X/200S6EG24N9K4R12 |
| R900961079 DBW10A2-5X/200S6EW230N9K4R12V |
| R901075701 DBW10A2-5X/200U6EG24N9K4 |
| R901043847 DBW10A2-5X/200U6EW230N9K4 |
| R900971685 DBW10A2-5X/200X6EG24NK4 |
| R900971455 DBW10A2-5X/200X6EG24N9K4 |
| R901086790 DBW10A2-5X/200X6EW230N9K4 |
| R900909516 DBW10A2-5X/200Y6EG24N9K4 |
| R900916162 DBW10A2-5X/200Y6EW230N9K4 |
| R900721105 DBW10A2-5X/200YS6EG24N9K4R12 |
| R900758546 DBW10A2-5X/200YS6EG24N9K4R12V |
| R901120385 DBW10A2-5X/200YU6EG24N9K4 |
| R900941213 DBW10A2-5X/200XY6EG24N9K4 |
| R900926054 DBW10A2-5X/315-6EG24N9K4 |
| R900958973 DBW10A2-5X/315-6EG24N9K4V |
| R900922377 DBW10A2-5X/315-6EW230N9K4 |
| R900935532 DBW10A2-5X/315S6EG24N9K4R12 |
| R900954472 DBW10A2-5X/315S6EG24N9K4R12V |
| R901130713 DBW10A2-5X/315S6EW230N9K4R12 |
| R900781325 DBW10A2-5X/315U6EG24NK4 |
| R900741804 DBW10A2-5X/315U6EG24N9K4 |
| R900772250 DBW10A2-5X/315U6EW230N9K4 |
| R901243992 DBW10A2-5X/315US6EG24N9K4R12 |
| R900726914 DBW10A2-5X/315X6EG24N9K4 |
| R900920436 DBW10A2-5X/315Y6EG24N9K4 |
| R900956639 DBW10A2-5X/315Y6EG24N9K4V |
| R900937506 DBW10A2-5X/315Y6EW230N9K4 |
| R900765091 DBW10A2-5X/315YS6EG24N9K4R12 |
Q1: What is the difference between A1 and B1 versions (DBW10A1 vs DBW10B1)?
Both are subplate-mounted pilot relief valves with solenoid unload and same adjustment method (hex socket + cap). The B1 version has a different pilot-stage damping orifice — it provides slightly different dynamic response (pressure overshoot/settling) vs A1. Pressure range, flow rating, solenoid, and mounting are identical. Selection depends on system stability requirements; A1 is the more commonly stocked general-purpose version.
Q2: Is this direct-acting or pilot-operated?
It is a pilot-operated (two-stage) relief valve with solenoid unloading. A pilot stage controls the main spool for stable high-flow relief; the integrated solenoid can command the valve to dump system pressure to tank.
Q3: How do I adjust the relief pressure?
With system depressurized, remove the protective cap, turn the setscrew with an Allen key — clockwise to increase, counterclockwise to decrease. Factory preset is typically near minimum of the spring range. Reinstall cap and verify with a pressure gauge. The solenoid does NOT change the set pressure.
Q4: What is the solenoid logic?
Standard: Solenoid DE-energized = relief active at set pressure. Solenoid ENERGIZED = system unloaded (P connected to T, near tank pressure). Confirm this matches your control logic before wiring.
Q5: Which subplate and electrical connector are needed?
Subplate: standard NG10 (ISO 6264) with P and T ports (G 1/2" or M18×1.5 on subplate), four M10 bolts @ ~35–40 N·m.
Electrical: EN 175301-803 Form A (DIN 43650-A) 3-pin + PE connector, 24 V DC. If the plug has LED indication, observe (+) / (–) polarity markings.
Q6: Common faults & causes?
Solenoid clicks but system does NOT unload: pilot orifice clogged, main spool stuck, no coil current (check ~18–28 Ω), manual override jammed.
Pressure won't reach set value / creeps early: wrong spring (not /200), pilot damping hole blocked, contaminated pilot seat, excessive T-backpressure (internal pilot drain).
Coil overheats / burnt smell: overvoltage (>10% above 24V), wrong voltage coil fitted, or mechanical damage — replace only with correct G24 wet-pin coil.
Chatter / unstable: air in system, high T-backpressure, worn pilot seat — bleed air first.
Q7: Does T-port backpressure affect set pressure?
Yes — this model has internal pilot drain. Backpressure at T adds 1:1 to the relief setpoint. If your tank line has >5 bar sustained backpressure, consider the DBW…Y version (external pilot drain to separate tank line).
Q8: Fluid & seal compatibility?
NBR seals = mineral oil (HL/HLP) & HFC (water-glycol). For HEES/HETG biodegradable oils or HFD phosphate ester → specify FKM (Viton) seal variant. Maintain oil cleanliness per ISO 4406 code 18/16/13 or better.
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...
Get in touch with us