Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
R983032412 2FRM6B36-2X/6QRV-IN001 Speed Control Valve
Pressure-compensated flow control valve manufactured by Rexroth in Germany. This 2-way throttle check valve maintains constant flow despite pressure fluctuations, featuring adjustable orifice with pressure-compensated spool for precise flow control.
Technical Specifications
Full Part Number
R983032412 (IN001 = individual inspection suffix)
Base Model
2FRM 6 - B36 - 2X / 6QRV
Valve Type
2-way throttle check valve with pressure compensator - flow control maintaining constant flow despite pressure fluctuations
Nominal Size (NG)
6 - sandwich mounting per ISO 6263 / NG6 (DIN 24340 Form C)
6 L/min (fine-to-medium metering - Q range typically 0.1-6 L/min)
Max. Operating Pressure
315 bar (ports A & B)
Cracking Pressure (Reverse Check)
approx. 0.5 bar (standard free-return)
Mounting Pattern
NG6 sandwich (4× M5 bolts), between directional valve & subplate
Seal Material
NBR (standard, code V - for mineral oil HL/HLP, HFC)
Hydraulic Fluid
Mineral oil HL, HLP per DIN 51524; HFC (water-glycol); HLPD, HVLP, HVLPD
Fluid Temperature Range
-30 °C to +80 °C (NBR seals)
Viscosity Range
10-800 mm²/s
Weight (approx.)
1.23 kg
Body Material
Steel / cast iron, zinc-plated
Related Products
R900423253
2FRM10-30/16LV
R900423254
2FRM10-31/2L
R900423255
2FRM10-31/25L
R900423256
2FRM10-31/25LB
R900423258
2FRM10-33/5L
R900423259
2FRM10-3X/5LB
R900423261
2FRM10-30/50LB
R900423271
2FRM16-30/60L
R900424034
2FRM16-3X/160LBV
R900424037
2FRM10-30/25Q
R900424673
2FRM10-30/10Q
R900424732
2FRM10-30/5Q
R900424831
2FRM10-3X/2Q
R900424887
2FRM10-31/10L
R900424893
2FRM10-2X/16L
R900424898
2FRM10-31/50LBV
R900424902
2FRM16-30/160LB
R900424903
2FRM16-3X/60LB
R900424904
2FRM16-30/60LV
R900424905
2FRM16-3X/100L
R900424906
2FRM16-3X/160L
Frequently Asked Questions
Q1: Is this a simple throttle / needle valve?
No. A simple needle valve lets flow vary with pressure difference. The 2FRM is pressure-compensated - the built-in compensator spool keeps the set flow essentially constant despite load or supply pressure changes (provided ≥~15 bar ΔP across compensator).
Q2: What does "B36 /6QRV" mean?
B36 = NG6 sandwich, rotary knurled knob with scale (0-max reference) + locking setscrew - adjustable by hand
/6 = maximum adjustable flow = 6 L/min (medium-fine version; also available: /1.5, /3, /10, /16, /25, /32)
Q = flow controlled in A→B direction
R = free reverse flow B→A via check valve
V = NBR seals (standard)
Q3: How do I set the flow?
Loosen the lock setscrew, turn the knurled knob clockwise to increase flow, counterclockwise to decrease. The knob has a relative scale - use a flow meter to correlate to actual L/min. Retighten the lock setscrew after setting.
Q4: How is it mounted?
As a sandwich (stackable) valve between a directional control valve and the NG6 subplate, same bolt pattern as ZDR/Z2FS sandwiches (4× M5). Observe the arrow on the valve body - A→B = controlled/metered flow, B→A = free return.
Q5: Does it work both ways?
No - one direction is pressure-compensated metered flow (A→B), the opposite direction (B→A) is free return through the check valve (no flow control, minimal pressure drop ~0.5 bar). For bidirectional flow control use two 2FRM valves.
Q6: Minimum pressure requirement?
The pressure compensator typically needs min. ~15 bar differential pressure across the compensator to regulate properly. Supply pressure must exceed the highest load pressure + ~15-20 bar + line losses.
Q7: Common faults & causes?
Flow varies with load pressure: compensator spool stuck (contamination) - check oil filtration (ISO 4406 18/16/13 or better); or insufficient ΔP across compensator
No flow / very low at max knob: valve installed backwards, or compensator/spool jammed
Cannot reach set flow / unstable: partially clogged orifice, cold-start high viscosity - flush system
Excessive heat: normal for flow controls - P_drop × Q = heat; ensure supply pressure isn't unnecessarily high above load requirement
Q8: Fluid & seal compatibility?
NBR seals = mineral oil (HL/HLP) & HFC (water-glycol). For HEES/HETG biodegradable oils or HFD phosphate ester → specify FKM (Viton) seal variant.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...