China R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth manual speed control valve
China R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth manual speed control valve

  1. China R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth manual speed control valve

R983032399 2FRM6A36-2X/10QRV-IN001 Rexroth manual speed control valve

  1. MOQ: 1
  2. Price:
  3. Get Latest Price
Delivery Time 2 weeks
Adjustable Flow Range​ 0.5 – 10 L/min​ (Code /10Q = max. flow 10 L/min)
Payment Terms Western Union,T/T,D/P,D/A,L/C
Packaging Details wooden box
Throttle Direction​ A → A₁​ (Meter-In); Free return A₁ → A via integrated check ("A" version)
Max. Drain Pressure (Y-port)​ 160 bar​ (recommend zero backpressure to tank)
Supply Ability 100
Nominal Size​ NG6 (D03 / ISO 4401-03-02-0-05)​
Max. Operating Pressure (P-port)​ 315 bar​
Brand Name Rexroth
Place of Origin Germany
Model Number R983032399 2FRM6A36-2X/10QRV-IN001
Certification ISO

View Detail Information

Inquiry by Email Get Latest Price
Chat online Now Ask for best deal
  1. Product Details
  2. Company Details

Product Specification

Delivery Time 2 weeks Adjustable Flow Range​ 0.5 – 10 L/min​ (Code /10Q = max. flow 10 L/min)
Payment Terms Western Union,T/T,D/P,D/A,L/C Packaging Details wooden box
Throttle Direction​ A → A₁​ (Meter-In); Free return A₁ → A via integrated check ("A" version) Max. Drain Pressure (Y-port)​ 160 bar​ (recommend zero backpressure to tank)
Supply Ability 100 Nominal Size​ NG6 (D03 / ISO 4401-03-02-0-05)​
Max. Operating Pressure (P-port)​ 315 bar​ Brand Name Rexroth
Place of Origin Germany Model Number R983032399 2FRM6A36-2X/10QRV-IN001
Certification ISO
High Light Rexroth manual speed control valveRexroth hydraulic control valveRexroth valve with warranty

Parameter Category

Parameter

Specification

General Information

Brand / Model

Rexroth (Germany), 2FRM6A36-2X/10QRV


Order Code (Material No.)

R983032399


Valve Type

2-way Pressure-Compensated Flow Control Valve (Sandwich Plate)

Performance Parameters

Nominal Size

NG6 (D03 / ISO 4401-03-02-0-05)


Max. Operating Pressure (P-port)

315 bar


Max. Drain Pressure (Y-port)

160 bar​ (recommend zero backpressure to tank)


Adjustable Flow Range

0.5 – 10 L/min​ (Code /10Q = max. flow 10 L/min)


Throttle Direction

A → A₁​ (Meter-In); Free return A₁ → A via integrated check ("A" version)


Compensation

Integrated pressure compensator (keeps ∆P across orifice constant, typ. 3–5 bar)

Mechanical Interface

Mounting Style

Sandwich Plate​ (installed between NG6 directional valve and subplate)


Mounting Bolts

4 × M5 (ISO 4762, Grade 10.9), torque ~8–10 Nm cross pattern


Adjustment Type

Spindle with Scale & Lock Nut ("36" code) + Protective Cap


Drain Requirement

External drain port Y​ → Tank (dedicated line, zero backpressure)


Weight

Approx. 1.4 kg

Media & Environment

Seal Material

FKM (Viton®)​ — suffix V


Compatible Fluids

Mineral Oils (HL/HLP), HFC (Water Glycol), HFD (Phosphate Ester — with FKM)


Operating Temp. Range

-20°C to +80°C​ (with FKM seals)


Fluid Cleanliness

ISO 4406 17/15/12​ or cleaner (fine orifice — tighter filtration required)


Special Note

IN001​ = Internal Inspection Lot Reference (no functional difference)

R983032407 2FRM6B36-2X/0.6QRV-IN001
R983032408 2FRM6B36-2X/1.5QMV-IN001
R983032409 2FRM6B36-2X/1.5QRV-IN001
R983032421 2FRM6B36-2X/3QMV-IN001
R983032410 2FRM6B36-2X/3QRV-IN001
R983032411 2FRM6B36-2X/6QMV-IN001
R983032412 2FRM6B36-2X/6QRV-IN001
R983032413 2FRM6B36-2X/10QMV-IN001
R983032414 2FRM6B36-2X/10QRV-IN001
R983032415 2FRM6B36-2X/16QMV-IN001
R983032416 2FRM6B36-2X/16QRV-IN001
R983032417 2FRM6B36-2X/25QMV-IN001
R983032418 2FRM6B36-2X/25QRV-IN001
R983032419 2FRM6B36-2X/32QMV-IN001
R983032420 2FRM6B36-2X/32QRV-IN001

R900205577 2FRM6B36-3X/0,2QMV
R900205509 2FRM6B36-3X/10QRV
R900205514 2FRM6B36-3X/32QMV
R900209927 2FRM6B76-34/10QRV
R900205521 2FRM6B76-3X/16QMV
R900205523 2FRM6B76-3X/25QMV
R900205510 2FRM6B36-3X/16QMV
R900216559 2FRM6A76-3X/16QMV
R900205512 2FRM6B36-3X/25QMV
R900986124 2FRM6A36-3X/32QMV
R900205517 2FRM6B36-3X/3QRV
R900205515 2FRM6B36-33/32QRV
R900205519 2FRM6B36-32/6QRV
R900205511 2FRM6B36-33/16QRV
R900205513 2FRM6B36-32/25QRV
R900205508 2FRM6B36-3X/10QMV

FAQ — Frequently Asked Questions

Q1: What is the difference between "A" and "B" versions of 2FRM6?

A:

  • 2FRM6A…​ = Throttling in A → A₁​ direction (meter-in on Port A side). Stacked between directional valve and subplate on the A-port.

  • 2FRM6B…​ = Throttling in B → B₁​ direction (meter-in on Port B side).

    For independent speed control on both extend and retract, one A-version and one B-version are typically stacked. The reverse flow always passes through a free-flow check valve with no restriction.

Q2: Why is an external drain (Y port) required and what if I don't connect it?

A:​ The pressure compensator spool​ needs a tank-pressure reference. The Y port must be plumbed directly to the reservoir with zero backpressure. If Y is blocked or sees backpressure, the compensator cannot regulate → flow becomes pressure-sensitive and unstable. Never omit or plug the Y port on a 2FRM valve.

Q3: How is this different from a Z2FS6 needle throttle valve?

A:​ The 2FRM6 has a pressure compensator​ maintaining constant ∆P across the metering orifice, so set flow stays constant despite load pressure changes​ on P or A ports. A Z2FS6 is a simple needle throttle — flow varies with ∆P. Use 2FRM when consistent actuator speed under varying load is critical; use Z2FS for basic, cost-sensitive throttling.

Q4: What does the "10Q" flow code mean in practice?

A:/10Q​ sets the maximum adjustable flow to 10 L/min​ (usable range approx. 0.5–10 L/min). Select the Q-code matching your required max flow — a smaller Q-range (/1.5Q, /3Q, /6Q) gives finer adjustment resolution. If your application needs >10 L/min on NG6, consider NG10 (2FRM10). Do not exceed the rated max or the orifice will be fully open with no regulation.

Q5: Why FKM (Viton) seals — is NBR not enough?

A:​ The V suffix = FKM seals, required for:

  • Temperatures above +70°C (up to +80°C)

  • Water glycol (HFC)​ or phosphate ester (HFD)​ fire-resistant fluids

    For standard mineral oil (HL/HLP) at normal temps, NBR is acceptable. The FKM version (this part R983032399) offers broader fluid compatibility and higher temp rating — select based on your actual hydraulic fluid.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Total Annual:

    1 million-10 millon

  • Employee Number:

    >50

  • Ecer Certification:

    Verified Supplier

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...

+ Read More

Get in touch with us

  • Reach Us
  • Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
  • Nan'an, Fujian Province, China
  • https://www.electrichydpump.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement