| Delivery Time | 2 weeks |
| Adjustable Flow Range | 0.5 – 10 L/min (Code /10Q = max. flow 10 L/min) |
| Payment Terms | Western Union,T/T,D/P,D/A,L/C |
| Packaging Details | wooden box |
| Throttle Direction | A → A₁ (Meter-In); Free return A₁ → A via integrated check ("A" version) |
| Max. Drain Pressure (Y-port) | 160 bar (recommend zero backpressure to tank) |
| Supply Ability | 100 |
| Nominal Size | NG6 (D03 / ISO 4401-03-02-0-05) |
| Max. Operating Pressure (P-port) | 315 bar |
| Brand Name | Rexroth |
| Place of Origin | Germany |
| Model Number | R983032399 2FRM6A36-2X/10QRV-IN001 |
| Certification | ISO |
View Detail Information
Explore similar products
R901411433 4WRPEH10C4B100L-3X/M/24A1 German Rexroth hydraulic proportional valve
R900549534 4WE6HA6X/EG24N9K4 Rexroth electromagnetic directional valve
R901507310 4WRPEH10C3B100L-3X/M/24F1 Proportional directional valve from Rexroth
R900553670 4WE6HB6X/EG24N9K4 Hydraulic directional valve solenoid valve Rexroth
Product Specification
| Delivery Time | 2 weeks | Adjustable Flow Range | 0.5 – 10 L/min (Code /10Q = max. flow 10 L/min) |
| Payment Terms | Western Union,T/T,D/P,D/A,L/C | Packaging Details | wooden box |
| Throttle Direction | A → A₁ (Meter-In); Free return A₁ → A via integrated check ("A" version) | Max. Drain Pressure (Y-port) | 160 bar (recommend zero backpressure to tank) |
| Supply Ability | 100 | Nominal Size | NG6 (D03 / ISO 4401-03-02-0-05) |
| Max. Operating Pressure (P-port) | 315 bar | Brand Name | Rexroth |
| Place of Origin | Germany | Model Number | R983032399 2FRM6A36-2X/10QRV-IN001 |
| Certification | ISO | ||
| High Light | Rexroth manual speed control valve ,Rexroth hydraulic control valve ,Rexroth valve with warranty | ||
|
Parameter Category |
Parameter |
Specification |
|---|---|---|
|
General Information |
Brand / Model |
Rexroth (Germany), 2FRM6A36-2X/10QRV |
|
Order Code (Material No.) |
R983032399 |
|
|
Valve Type |
2-way Pressure-Compensated Flow Control Valve (Sandwich Plate) |
|
|
Performance Parameters |
Nominal Size |
NG6 (D03 / ISO 4401-03-02-0-05) |
|
Max. Operating Pressure (P-port) |
315 bar |
|
|
Max. Drain Pressure (Y-port) |
160 bar (recommend zero backpressure to tank) |
|
|
Adjustable Flow Range |
0.5 – 10 L/min (Code /10Q = max. flow 10 L/min) |
|
|
Throttle Direction |
A → A₁ (Meter-In); Free return A₁ → A via integrated check ("A" version) |
|
|
Compensation |
Integrated pressure compensator (keeps ∆P across orifice constant, typ. 3–5 bar) |
|
|
Mechanical Interface |
Mounting Style |
Sandwich Plate (installed between NG6 directional valve and subplate) |
|
Mounting Bolts |
4 × M5 (ISO 4762, Grade 10.9), torque ~8–10 Nm cross pattern |
|
|
Adjustment Type |
Spindle with Scale & Lock Nut ("36" code) + Protective Cap |
|
|
Drain Requirement |
External drain port Y → Tank (dedicated line, zero backpressure) |
|
|
Weight |
Approx. 1.4 kg |
|
|
Media & Environment |
Seal Material |
FKM (Viton®) — suffix V |
|
Compatible Fluids |
Mineral Oils (HL/HLP), HFC (Water Glycol), HFD (Phosphate Ester — with FKM) |
|
|
Operating Temp. Range |
-20°C to +80°C (with FKM seals) |
|
|
Fluid Cleanliness |
ISO 4406 17/15/12 or cleaner (fine orifice — tighter filtration required) |
|
|
Special Note |
IN001 = Internal Inspection Lot Reference (no functional difference) |
![]()
| R983032407 2FRM6B36-2X/0.6QRV-IN001 |
| R983032408 2FRM6B36-2X/1.5QMV-IN001 |
| R983032409 2FRM6B36-2X/1.5QRV-IN001 |
| R983032421 2FRM6B36-2X/3QMV-IN001 |
| R983032410 2FRM6B36-2X/3QRV-IN001 |
| R983032411 2FRM6B36-2X/6QMV-IN001 |
| R983032412 2FRM6B36-2X/6QRV-IN001 |
| R983032413 2FRM6B36-2X/10QMV-IN001 |
| R983032414 2FRM6B36-2X/10QRV-IN001 |
| R983032415 2FRM6B36-2X/16QMV-IN001 |
| R983032416 2FRM6B36-2X/16QRV-IN001 |
| R983032417 2FRM6B36-2X/25QMV-IN001 |
| R983032418 2FRM6B36-2X/25QRV-IN001 |
| R983032419 2FRM6B36-2X/32QMV-IN001 |
| R983032420 2FRM6B36-2X/32QRV-IN001 |
| R900205577 2FRM6B36-3X/0,2QMV |
| R900205509 2FRM6B36-3X/10QRV |
| R900205514 2FRM6B36-3X/32QMV |
| R900209927 2FRM6B76-34/10QRV |
| R900205521 2FRM6B76-3X/16QMV |
| R900205523 2FRM6B76-3X/25QMV |
| R900205510 2FRM6B36-3X/16QMV |
| R900216559 2FRM6A76-3X/16QMV |
| R900205512 2FRM6B36-3X/25QMV |
| R900986124 2FRM6A36-3X/32QMV |
| R900205517 2FRM6B36-3X/3QRV |
| R900205515 2FRM6B36-33/32QRV |
| R900205519 2FRM6B36-32/6QRV |
| R900205511 2FRM6B36-33/16QRV |
| R900205513 2FRM6B36-32/25QRV |
| R900205508 2FRM6B36-3X/10QMV |
Q1: What is the difference between "A" and "B" versions of 2FRM6?
A:
2FRM6A… = Throttling in A → A₁ direction (meter-in on Port A side). Stacked between directional valve and subplate on the A-port.
2FRM6B… = Throttling in B → B₁ direction (meter-in on Port B side).
For independent speed control on both extend and retract, one A-version and one B-version are typically stacked. The reverse flow always passes through a free-flow check valve with no restriction.
Q2: Why is an external drain (Y port) required and what if I don't connect it?
A: The pressure compensator spool needs a tank-pressure reference. The Y port must be plumbed directly to the reservoir with zero backpressure. If Y is blocked or sees backpressure, the compensator cannot regulate → flow becomes pressure-sensitive and unstable. Never omit or plug the Y port on a 2FRM valve.
Q3: How is this different from a Z2FS6 needle throttle valve?
A: The 2FRM6 has a pressure compensator maintaining constant ∆P across the metering orifice, so set flow stays constant despite load pressure changes on P or A ports. A Z2FS6 is a simple needle throttle — flow varies with ∆P. Use 2FRM when consistent actuator speed under varying load is critical; use Z2FS for basic, cost-sensitive throttling.
Q4: What does the "10Q" flow code mean in practice?
A: /10Q sets the maximum adjustable flow to 10 L/min (usable range approx. 0.5–10 L/min). Select the Q-code matching your required max flow — a smaller Q-range (/1.5Q, /3Q, /6Q) gives finer adjustment resolution. If your application needs >10 L/min on NG6, consider NG10 (2FRM10). Do not exceed the rated max or the orifice will be fully open with no regulation.
Q5: Why FKM (Viton) seals — is NBR not enough?
A: The V suffix = FKM seals, required for:
Temperatures above +70°C (up to +80°C)
Water glycol (HFC) or phosphate ester (HFD) fire-resistant fluids
For standard mineral oil (HL/HLP) at normal temps, NBR is acceptable. The FKM version (this part R983032399) offers broader fluid compatibility and higher temp rating — select based on your actual hydraulic fluid.
Company Details
Business Type:
Manufacturer,Exporter
Total Annual:
1 million-10 millon
Employee Number:
>50
Ecer Certification:
Verified Supplier
Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha... Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd. has been established for many years and has now developed into an international trading company supplying various hydraulic machinery parts, oil pumps and valves. We are one of the few Chinese companies with multiple products and cha...