| Payment Terms | T/T, Western Union |
| Supply Ability | 50 sets per day |
| Delivery Time | 3 work days |
| Packaging Details | wooden package |
| Explosion Proof Grade | Exia II CT5Ga, Exd II BT5Gb |
| Connection Form | Stabndard:DIN2501 standard flange |
| Port | Shenghai/ Shenzhen |
| Display Type | Analog |
| Installation Height | 350mm |
| Output | 4-20mA |
| Scale Units | L/min |
| Precision Class | 1.5 |
| Applicable Medium | Gas, Liquid |
| Exportation | Two-wire System 4~20MA |
| Measurement Range | 0-100 L/min |
| Connection | Flange |
| Flow Direction | Bottom to Top |
| Warranty | 18 months |
| Temperature Rating | Max. 100°C |
| Brand Name | INSTE |
| Model Number | INSTE H250 |
| Place of Origin | Jiangsu, China |
View Detail Information
Explore similar products
High Accuracy Explosion Proof Metal Tube Rotameter For Water Liquid Medium Gas
LCD Display DN15-50 Digital Metal Tube Rotameter High Accuracy
Stable Rotary DN80 Metal Tube Flowmeter With Long Service Life
4-20mA Precise DN150 Metal Rotameter Low Maintenance
Product Specification
| Payment Terms | T/T, Western Union | Supply Ability | 50 sets per day |
| Delivery Time | 3 work days | Packaging Details | wooden package |
| Explosion Proof Grade | Exia II CT5Ga, Exd II BT5Gb | Connection Form | Stabndard:DIN2501 standard flange |
| Port | Shenghai/ Shenzhen | Display Type | Analog |
| Installation Height | 350mm | Output | 4-20mA |
| Scale Units | L/min | Precision Class | 1.5 |
| Applicable Medium | Gas, Liquid | Exportation | Two-wire System 4~20MA |
| Measurement Range | 0-100 L/min | Connection | Flange |
| Flow Direction | Bottom to Top | Warranty | 18 months |
| Temperature Rating | Max. 100°C | Brand Name | INSTE |
| Model Number | INSTE H250 | Place of Origin | Jiangsu, China |
| High Light | DN150 Metal Tube Rotameter ,DN150 metal tube flowmeter ,Accurate Metal Tube Rotameter | ||
Advanced Metal Tube Rotameter Magnetic Coupling System Design Accurate DN150
The Advanced DN150 Metal Tube Rotameter is a heavy-duty variable area flow meter engineered for high-volume industrial flow measurement. Specifically designed for DN150 (6-inch) pipelines, this meter utilizes a sophisticated non-contact magnetic coupling system to provide accurate and real-time flow data for liquids, gases, and steam in the most demanding environments.
Constructed with a robust all-metal body, the DN150 series eliminates the risks associated with glass tube meters, making it the ideal choice for high-pressure, high-temperature, and hazardous industrial applications.
| Measuring range |
Water (20ºC) 16~150000 l/h. Air(0.1013MPa 20ºC) 0.5~4000 m3/h. |
| Range ratio | 10:1(Special type 20:1). |
| Accuracy class | 2.5(Special type 1.5% or 1.0%). |
| Working pressure |
DN15~DN50 PN16MPa (Special type 25MPa). DN80~DN150 PN10MPa (Special type 16MPa). Pressure rating of jacket 1.6MPa. |
| Medium temperature |
Normalized type -80ºC~+220ºC. High-temperature type 300ºC. Lined with FEP type ≤85ºC. |
| Ambient temperature |
-40ºC~+120ºC(Remote display without LCD≤85ºC). (Remote display with LCD≤70ºC). |
| Dielectric viscosity |
1/4" NPT, 3/8" NPT 1/2" NPT≤5mPa.s 3/4" NPT,1" NPT ≤250mPa.s |
| Output |
Standard signal: two-wire system 4 ~ 20mA (with HART communication). Standard signal: three-wire system 0 ~ 10mA. Alarm signal:1.Two-way relay output. 2.One-way or two-approach switches . Pulse signal output: 0-1KHz isolated output. |
| Process connection |
Standard type:24VDC±20%. AC type:220VAC(85~265VAC) (optional). |
| Connection mode |
Flange Thread Tri-clamp |
| Levels of protection | IP65/IP67. |
| Ex-mark | Intrinsically safe:ExiaIICT3~6. Exd type:ExdIICT4~6. |
Features
1. Robust all-metal structure design.
2. Suitable for gas and liquid measurement in various industries.
3. Cone-shape measuring tube design,which has wide measuring range and good linearity.
4. Wetted parts material are optional: SS304, SS316L, FEP, Hastelloy C, Titanium.
5. Adopt advanced magnetic coupling system design, improve the accuracy and stability.
6. The upper row displays the instantaneous flow, the lower row displays the total flow.
7. For the digital LCD display type, the flow range of the instantaneous flow can be corrected onsite based on the different measuring medium.
8. It adopts advanced six level data backup technology,data of total flow can be saved automatically when power-off,(the total flow sending period id 0.3s).
9. Besides AC/DC power supply, it supports battery power supply function.
10. No need to open the cover, it can be operated by a magnetic pen; the key operation function is also available.
11. Through the HART protocol, you can use the handheld operator or host computer software to perform partial or full configuration operations on the flowmeter.
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
10000000-20000000
Employee Number:
100~120
Ecer Certification:
Verified Supplier
About Us Established in 2016, INSTE is a leading manufacturer of high-quality industrial instruments, specializing in pressure gauges, flow meters, temperature sensors, control valves, etc. With decades of expertise, we are committed to delivering reliable, accurate, and durable soluti... About Us Established in 2016, INSTE is a leading manufacturer of high-quality industrial instruments, specializing in pressure gauges, flow meters, temperature sensors, control valves, etc. With decades of expertise, we are committed to delivering reliable, accurate, and durable soluti...
Get in touch with us
Leave a Message, we will call you back quickly!