High purity raw material preparation, minimal decomposition products, and good stability of plating solution
The surface quickly becomes bright, with excellent brightness, high and uniform surface flatness, and strong coverage ability in low current density areas
Specialized for hanging plating, clear type, easy to chrome, stable process, and convenient maintenance of plating solution
Suitable for single-layer direct nickel or multi-layer nickel processes with high anti-corrosion performance requirements
Fast brightening, excellent leveling, and high coating fullness.
Good flexibility and high adhesion.
Stable bath, long service cycle, low operating cost.
Plating Solution Formula
Item
Unit
Range
Nickel Sulfate
g/L
200–300
Nickel Chloride
g/L
45–60
Boric Acid
g/L
40–50
High-Speed Nickel Softener
mL/L
5–8
High-Speed Nickel Brightener
mL/L
0.3–0.5
Wetting Agent
mL/L
1–2
Temperature
℃
50–60
pH
-
4.2–4.8
Cathode Current Density
A/dm²
2–6
3. Solution Preparation
Fill a spare tank with half the working volume of water; heat to ~55°C.
Add nickel sulfate and nickel chloride; stir to dissolve completely.