China ET 1 Sandwich Immunosorbent Assay Kit High Sensitive Mouse ELISA Kit 2 Hours
China ET 1 Sandwich Immunosorbent Assay Kit High Sensitive Mouse ELISA Kit 2 Hours

  1. China ET 1 Sandwich Immunosorbent Assay Kit High Sensitive Mouse ELISA Kit 2 Hours

ET 1 Sandwich Immunosorbent Assay Kit High Sensitive Mouse ELISA Kit 2 Hours

  1. MOQ: Negotiation
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms Western Union, T/T
Supply Ability In Stock
Delivery Time 1-3 business days, bulk order within one week
Packaging Details Wrapped with ice pack and styrofoam package
Assay Length 2 hours
Sample Serum,plasma,urine,tissue,cell culture supernatant
Discount Available
Quality CE, ISO
Assay Principle Sandwich
Bulk Order Yes
Brand Name BT Lab
Model Number Cat.No E0257Mo
Certification CE, ISO9001:2005, MSDS
Place of Origin Shanghai, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms Western Union, T/T Supply Ability In Stock
Delivery Time 1-3 business days, bulk order within one week Packaging Details Wrapped with ice pack and styrofoam package
Assay Length 2 hours Sample Serum,plasma,urine,tissue,cell culture supernatant
Discount Available Quality CE, ISO
Assay Principle Sandwich Bulk Order Yes
Brand Name BT Lab Model Number Cat.No E0257Mo
Certification CE, ISO9001:2005, MSDS Place of Origin Shanghai, China
High Light sandwich elisa kitrat elisa kit

ET 1 Sandwich Immunosorbent Assay Kit High Sensitive Mouse ELISA Kit 2 Hours Assay Length
​​

Cat.No E0257Mo

Standard Curve Range: 1ng/L - 400ng/L

Sensitivity: 0.43ng/L

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

*This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.
 

Intended Use

This sandwich kit is for the accurate quantitative detection of Mouse Endothelin 1 (also known as ET-1) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

 

Assay Principle

This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Mouse ET-1 antibody. ET-1 present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Mouse ET-1 Antibody is added and binds to ET-1 in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated ET-1 antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Mouse ET-1. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.
 

Precautions

  • Prior to use, the kit and sample should be warmed naturally to room temperature 30 minutes.
  • This instruction must be strictly followed in the experiment.
  • Once the desired number of strips has been removed, immediately reseal the bag to protect the remain from deterioration. Cover all reagents when not in use.
  • Make sure pipetting order and rate of addition from well-to-well when pipetting reagents.
  • Pipette tips and plate sealer in hand should be clean and disposable to avoid cross-contamination.
  • Avoid using the reagents from different batches together.
  • Substrate solution B is sensitive to light, don’t expose substrate solution B to light for a long time.
  • Stop solution contains acid. Please wear eye, hand and skin protection when using this material. Avoid contact of skin or mucous membranes with kit reagent.
  • The kit should not be used beyond the expiration date.

 

Reagent PreparationAll reagents should be brought to room temperature before use.Standard Reconstitute the 120μl of the standard (480ng/L) with 120μl of standard diluent to generate a 240ng/L standard stock solution. Allow the standard to sit for 15 mins with gentle agitation prior to making dilutions. Prepare duplicate standard points by serially diluting the standard stock solution (240ng/L) 1:2 with standard diluent to produce 120ng/L, 60ng/L, 30ng/L and 15ng/L solutions. Standard diluent serves as the zero standard(0 ng/L). Any remaining solution should be frozen at -20℃ and used within one month. Dilution of standard solutions suggested are as follows:

 

240ng/L Standard No.5 120μl Original Standard + 120μl Standard Diluent
120ng/L Standard No.4 120μl Standard No.5 + 120μl Standard Diluent
60ng/L Standard No.3 120μl Standard No.4 + 120μl Standard Diluent
30ng/L Standard No.2 120μl Standard No.3 + 120μl Standard Diluent
15ng/L Standard No.1 120μl Standard No.2 + 120μl Standard Diluent

 

Standard Concentration Standard No.5 Standard No.4 Standard No.3 Standard No.2 Standard No.1
480ng/L 240ng/L 120ng/L 60ng/L 30ng/L 15ng/L

 

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 25x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

 

Summary

1. Prepare all reagents, samples and standards.

2. Add sample and ELISA reagent into each well. Incubate for 1 hour at 37°C.

3. Wash the plate 5 times.

4. Add substrate solution A and B. Incubate for 10 minutes at 37°C.

5. Add stop solution and color develops.

6. Read the OD value within 10 minutes.

 

Calculation of Result

Construct a standard curve by plotting the average OD for each standard on the vertical (Y) axis against the concentration on the horizontal (X) axis and draw a best fit curve through the points on the graph. These calculations can be best performed with computer-based curve-fitting software and the best fit line can be determined by regression analysis.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Exporter,Seller

  • Year Established:

    2010

  • Ecer Certification:

    Active Member

Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc... Shanghai Korain Biotech Co. was built in 2010. As an creator in reagents and tools for life science, Korainbio provide researchers with tools and scientific support including 30,000 antibodies, 1000+ proteins and 5000 ELISA kits. We aim to be a leading provider with world-class level for the researc...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai Korain Biotech Co., Ltd
  • #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China
  • https://www.elisatest-kit.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement